My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6342 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6342 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 11:06:22 AM
Creation date
2/19/2025 10:58:15 AM
Metadata
Fields
Template:
Building Plans
Street #
6342
Location
Cobble Bliss St
Contractor
Lennar Homes LLC
Building Plans - Permit #
21423
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br />v <br />M <br />N <br />E <br />s <br />v <br />ATTIC VENTILATION CALCULATIONS - B <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total 3Q. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />. <br />SQ. INof <br />SQ. IN. of <br />Ventilators <br />ventilation <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev ) <br />required <br />needed <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />23.0 <br />1.0 <br />Floor <br />2719 <br />2610 <br />373 <br />1305 <br />93 <br />653 <br />483.0 <br />345.0 <br />138.0 <br />(Zone 1) <br />*"NOTE" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN - ELEV-B <br />SCALE: Y4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />"G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />I Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion ol <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SO. FT. <br />*If not enough vented soffit is provided due to fire protection, the contractor shall use <br />following approved vents: <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear FL of Deck -Air Needed) <br />O <br />O <br />Z o <br />z <br />z <br />Q <br />a <br />cn c� <br />ate-+ cn <br />w <br />�V — <br />O w <br />120 <br />i� N U <br />N <br />I_ <br />_ <br />0 M MMM <br />� N <br />C) qs <br />YC <br />- 2 <br />a <br />U) <br />Qo <br />B D• <br />N C <br />V �1 <br />N �O <br />Z m z- <br />U) <br />� 4 Col.- <br />LU w � <br />�Z0 <br />0 <br />till,0 <br />a <br />04o <br />E <br /><� <br />r <br />R O F E SS C'�������� <br />A/ r�°,tl6itt�tt\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />W <br />Z Q <br />�zOox <br />L <br />m <br />g <br />O <br />V <br />M <br />L <br />a� <br />���] <br />10 <br />O <br />� <br />W <br />o <br />LA <br />N <br />M <br />z <br />�o <br />o <br />J <br />C-4 <br />Lu <br />Z <br />00 <br />J <br />N <br />Ln <br />Li j <br />z <br />LU <br />Q <br />z� <br />a <br />F <br />Ln <br />00 <br />N <br />Ck <br />Z <br />U <br />LU <br />Lu <br />0n <br />g <br />N <br />z <br />SCALE : AS NOTED <br />DATE : 4/5/2019 <br />TECH: JBERCHAL <br />VERSION N0. 42 <br />SHEET NO. <br />5.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.