Laserfiche WebLink
5PEG I F I GATT ONS <br />I. I. GONSTRUGTION <br />I. I. I. AGI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />I. 1.2. A5GE5/AGI 530-13, TM5 402-16 4 ASGEb/AGI 550.1-15, TM5 602-Ib <br />SPECIFICATIONS FOR MASONRY STRUCTURES. <br />I. 1.5. A5TM G270-12a, G476-10, AND Gq0-14 SPEGIFIGATIONS FOR MASONRY STRUGTURES <br />I. I. 4. NATIONAL DESIGN SPEGIFIGATION5 (ND5) FOR HOOD GON5TRUGTION, 2015 EDITION, AND ALL <br />AGGOMPANYING SUPPLEMENTS. <br />1. 1. 5. FLORIDA RESIDENTIAL CODE (FRG), FLORIDA BUILDING CODE (FBG), 6th EDITION (2017) <br />I. I, b. "MANUAL OF STEEL CONSTRUCTION, ALLONABLE STRESS DE51ON", BY THE AMERICAN <br />INSTITUTE OF STEEL GONSTRUGTION, (AISG) <br />I. I. 7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED HOOD TRUSSES" BY THE <br />TRUSS PLATE INSTITUTE TPI 1-14. <br />1.2. DESION : <br />I. 2. I. AGI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL GONGRETE <br />I. 2. 2. ASGE5/AGI 530-13, TM5 402-16 ff ASGE6/AGI 530.1-13, TM5 602-16 <br />SPEGIFIGATION5 FOR MASONRY STRUGTURES. <br />I. 2. 3. ASTM G270-12a, G416-10, AND Gq0-14 5PEGIFIGATION5 FOR MASONRY STRUGTURES <br />I. 2. 4. NATIONAL DESIGN SPECIFICATIONS (ND5) FOR HOOD CONSTRUCTION, 2015 EDITION, AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />1. 2. 5. PLYWOOD DE51ON SPEGIFIGATION5 (APA) <br />1. 2. 6. FLORIDA RESIDENTIAL CODE (FRG), FLORIDA BUILDING CODE (FBG), 6th EDITION (2017) <br />1.5. <br />SHOP DRAW I NOS <br />I. 3. I. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS <br />DURING THE PREPARATION OF SHOP PRANIN65 WITHOUT WRITTEN APPROVAL FROM <br />THE ENGINEER OF RECORD. <br />I. 3. 2. ALL SHOP DRANINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO <br />THE GOMMENGEMENT OF GON5TRUGTION. <br />ALL ROOF AND FLOOR TRU55 SHOP DRANING5 ARE TO BE SIGNED AND SEALED BY A FLA. <br />REG. PE. AND SHALL INGLUDE : DRAHINGS AND CALCULATIONS, REAGTION5 AND BEARING <br />POINTS, BRAGING REQUIREMENTS, AND GONNEGTIONS TO SUPPORTING TRU55 MEMBERS. <br />2. DE510N LOADS <br />TH15 5TRUGTURE HAS BEEN DESIGNED IN AGGORDANGE HITH THE 6th ED, (2017) FLORIDA <br />BUILDING CODE, RESIDENTIAL <br />BUILDING GATEGORY: II <br />2.1. DEAD LOADS: <br />ROOF <br />TILE (TG=15P5F, BG=IOP5F) 25PSF <br />ASPHALT SHINGLE (TG=7P5F, BG=IOP5F) 17P5F <br />METAL (TG=IOPSF, BG=IOPSF) 20P5F <br />FLOOR <br />TILE (GERAMIG, 1/2" MORTAR BED) 25PSF <br />GARPET OR HOOD 15P5F <br />2. 2. LIVE LOADS : <br />ROOF <br />20P5F <br />FLOOR <br />ONE- AND TNO-FAMILY DWELLINGS <br />UNINHABITABLE ATTIC, NO STORAGE <br />IOPSF <br />UNINHABITABLE ATTIC, LIMITED STORAGE <br />20P5F <br />HABITABLE ATTIGS, SLEEPING AREAS <br />50PSF <br />OTHER <br />40PSF <br />EXTERIOR DECKS <br />SAME AS OGGUPANGY SERVED <br />RAILING - NONGONGURRENT <br />50PLF OR 20OLB <br />LIVE LOAD REDUCTIONS <br />PER CODE <br />2. 3. ROOF SNOW LOAD DATA. - <br />GROUND SNOW LOAD, Pg = N/A <br />2. 4. WIND LOADS : <br />BASIC HIND SPEED, V (3-5EG. GUST) <br />140MPH (Va5d=108MPH) <br />HIND EXF05URE <br />G <br />INTERNAL PRE55URE GOEFFIGIENT <br />+/-0.18 <br />G ff G DE51ON PRESSURE <br />SEE PLAN <br />HIND BORNE DEBRIS PROTEGTION <br />5HUTTER/IMPAGT 6LA55 <br />2. S. SEISM IG DESIGN DATA: <br />SEISMIC IMPORTANCE FAGTOR, le <br />I.O <br />SEISMIC, RISK GATEGORY <br />II <br />MAPPED 5RA, 55, 51 <br />N/A <br />51TE GLASS <br />A <br />DE51ON 5RG, 5D5, SDI <br />N/A <br />SEISMIC, DESIGN GATEOORI' <br />N/A <br />BASIC SFRS <br />MA50NRY HALLS <br />DESIGN BASE SHEAR, (UNFAGTORED) <br />N/A <br />SEISMIC, RESPONSE GOEFFIGIENT, GS <br />N/A <br />RESPONSE MODIFICATION FACTOR, R <br />N/A <br />ANALYSIS PROCEDURE <br />ELF <br />2. 6. FLOOD DESIGN DATA: <br />DATUM <br />NAVD88 <br />FLOOD ZONE <br />"X" <br />BASE FLOOD ELEVATION: <br />N/A <br />LONEST PROPOSED FLOOR ELEVATIONS <br />N/A <br />3. DEFLEGTIONS: <br />LIVE LOAD L/360 <br />TOTAL LOAD L/240 <br />4. MATERIALS <br />4.1. RE I NFORG I NO STEEL <br />4. I. <br />I. REINFORGING STEEL SHALL BE ASTM A615/A615M-Oq GRADE 40, f'y = 40 Ksi <br />4. I. <br />2. LAP SPLICE SHALL BE A5 FOLLONS: #5 BAR 25", #4 BAR 20", #3 BAR 15". <br />4. I. <br />3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORGING ARE TO THE GENTERLINE OF <br />EAGH BAR EXCEPT HHERE THE COVER DIMENSION 15 5HONN TO THE FACE OF THE GONGRETE. <br />4. I. <br />4. REINFORGING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. <br />4. 1. <br />5. REINFORGING MEGHANIGAL GOUPLER5 ARE TO DEVELOP 125 % OF THE REQUIRED <br />YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. <br />4. I. <br />6. DESIGN COVER REQUIREMENTS : <br />G-I-P CONCRETE FORMED AGAINST EARTH : 51, <br />G-I-P GONGRETE EXPOSED TO EXTERIOR : 211 <br />G-I-P GONGRETE NOT EXP05ED V2" <br />GROUT FILLED MASONRY : 3/4 <br />4. <br />1. 7. HELPED HIRE FABRIC, (HNF): AIOb4/A1064M-16a <br />4. <br />I. 8. DETAIL REINFORCEMENT IN AGGORDANGE HITH AGI 315-LATE5T EDITION. <br />4. 2. CONCRETE : <br />MODULES OF <br />4. 2. I. <br />CONCRETE TYPE <br />MIN. 28 DAY <br />DESIGN (f G) <br />ELASTICITY <br />DE51ON (E) <br />G-I-P CONCRETE (NORMAL HEIGHT) <br />2,500 Psi <br />2,850 Ksi <br />G-I-P GONGRETE (NORMAL NEIGHT) HERNANDO GO. ONLY <br />3,000 Psi <br />5,122 Ksi <br />G-I-P GROUT <br />1 5,000 Psi <br />I 3,122 Ksi <br />4. 2. 2. <br />CONCRETE SHALL GON515T OF I" MAXIMUM AGGREGATE CONCRETE MIX HITH SLUMP <br />BETHEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL <br />CRITERIA. <br />4. 2. 3. <br />GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX <br />HITH SLUMP BETHEEN 8" AND 10" AT TIME OF PLACEMENT. SEE SPEGIFIGATION5 FOR <br />ADDITIONAL CRITERIA. <br />4. 2. 4. <br />GON5TRUGTION JOINTS HILL BE PERMITTED <br />4. 2. 5. <br />METHOD OF CONCRETE FORMING, PLACEMENT AND GURING SHALL BE CONDUCTED IN <br />AGGORDANGE HITH THE SPEGIFIGATIONS AS STATED. <br />4. 2. 6. <br />EARTH SUPPORTED SLABS (EXGLUDING EXTERIOR HALKNAY5 8 DRIVEWAYS) <br />3 1/2" MIN. THICKNESS N/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 HNF <br />IN TOP OF 1-1/2" OF SLAB. FIBER MESH PER DE51ON MIX MAY BE USED I.L.O. HHF <br />GONTRAGTORS DI5GRETION. <br />4. 2. 7. <br />GONGRETE PLAGEMENT PRAGTIGES SHALL BE IN AGGORDANGE N/ ALL <br />AGI- MGP 201-1 STANDARDS. <br />4. 3. GONGRETE MASONRY : <br />4. 3. I. <br />FILLED CELLS H/ (1) #5 BAR SHALL BE LOCATED PER PLAN. <br />4. 3. 2. <br />LOAD BEARING GONGRETE MASONRY BLOCK SHALL BE A5TM G110-14, TYPE 11 <br />NON -MOISTURE CONTROLLED. <br />4. 3. 3. <br />ALL CELLS 4 GAVITIE5 BELON GRADE HILL BE FILLED N/ CONCRETE IN ALL STEM HALLS <br />4. 3. 4. <br />THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE Pm = 2,000 PSI MINIMUM <br />4. 3. 5. <br />METHOD OF GONGRETE MASONRY PLAGEMENT AND CONSTRUCTION SHALL BE <br />GONDUCTED IN AGGORDANGE HITH THE 5PEGIFIGATION5 AS STATED. <br />4. 3. 6. <br />MORTAR SHALL BE TYPE "S" FOR ALL MASONRY GON5TRUGTION. <br />4. 3. 7. <br />MASONRY ROUGH OPENING MAY VARY IN THE GROSS SECTION DIMENSION OR ELEVATION <br />DIMEN5ION SPECIFIED ON THE APPROVED PLANS FROM -1/4" TO +I/2" PER SECTION R(06.3.1.1 <br />4.4. STRUCTURAL LUMBER : <br />4. 4. 1.1. <br />INTERIOR LOAD BEARING HALLS 5PF STUD OR BETTER, fb = 675 P51, E = 1200 Ksl <br />ALL EXTERIOR FRAMING 5PF #2 OR BETTER, fb = 8-75 PSI, E = 1,40OK51 <br />4. 4. 1.2. <br />ALL FRAME HALLS TO BE GON5TRUGTED USING 5PF , <br />STUD QUALITY OR BETTER, UNLESS NOTED OTHERWISE <br />4. 4. 2. <br />ALL PLYWOOD USED FOR EXTERIOR APPLIGATION5 <br />SHALL BE APA RATED 5HEATHIN6 EXP I U.N.O. <br />4. 4. 3. <br />ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUGH AS SUB FLOORING AND <br />SHEAR HALLS SHALL BE APA RATED SHEATHING EXP I U.N.O. <br />4. 4. 4. <br />IF OSB BOARD 15 TO BE USED IN PLACE OF PLYWOOD IS TO HAVE 51MILAR OR <br />GREATER SECTION PROPERTIES. <br />4. 4. 5. <br />ONLY 5TRUGTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. HOOD IN <br />CONTACT HITH CONCRETE 15 TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />4. 4. 6. <br />WHEN PRE ENGINEERED TRUSSES ARE GALLED FOR ON THE PLANS THE <br />MANUFACTURER IS TO SUBMIT SHOP PRANINGS TO THE ENGINEER OF RECORD. <br />4. 4.1. <br />DESIGN, FABRICATE AND ERECT HOOD TRUSSES IN AGGORDANGE HITH THE "DESIGN <br />SPECIFICATION FOR LIGHT METAL PLATE GONNECTED HOOD TRUSSES" BY THE <br />AN51/TPI 1-14, BG51 2015 <br />4. 4. 8. <br />UNTREATED HOOD SHALL NOT BE IN DIRECT GONTAGT HITH GONGRETE. SEAT PLATES <br />SHALL BE PROVIDED AT BEARING LOCATIONS NITHOUT NOODEN TOP PLATES. <br />4. 4. q. <br />ALL EXTERIOR FRAME HALLS SHALL BE STUCCO FINISH AND SHALL BE APPLIED IN STRICT <br />AGGORDANGE HITH THE FRG SECTION R703.1.2 AND HITH ASTM Gg26 INCLUDING THE <br />REFERENCE IN ASTM Gg26 5EGTION 8 TO 5EGTION XI.4.2 OF THE APPENDIX - 1/8" TOTAL <br />THIGKNE55 APPLIED IN THREE LAYERS (3/8" - 3/8" - 1/8") OVER METAL LATH OVER HATER <br />RESISTIVE BARRIER. THE HATER RESISTIVE BARRIER SHALL INGLUDE A HATER -RESISTIVE <br />VAPOR -PERMEABLE BARRIER HITH A PERFORMANGE AT LEAST EQUIVALENT TO THO <br />LAYERS OF GRADE D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED <br />INDEPENDENTLY SUCH THAT EAGH LAYER PROVIDES A SEPARATE GONTINUOU5 PLANE AND <br />SHALL BE ATTAGHED DIRECTLY TO THE SHEATHING OVER FLASHING INSTALLED IN <br />AGGORDANGE HITH THE APPLICABLE BUILDING CODE AND MANUFAGTURER'S <br />SPEGIFIGATION5. GURIN5 TIME FOR 3-GOAT STUGGO, EACH GOAT SHALL BE KEPT IN A M015T <br />CONDITION FOR AT LEAST 48 HOURS PRIOR TO THE APPLICATION OF THE NEXT GOAT. THE <br />2ND GOAT SHALL NOT BE APPLIED SOONER THAN 48 HR5 AFTER APPLICATION OF THE I5T <br />GOAT. THE FINISH GOAT SHALL NOT BE APPLIED SOONER THAN 7 DAYS AFTER THE <br />APPLICATION OF THE 2ND GOAT. UNLE55 APPLICATIONS INSTALLED IN AGGORDANGE WITH <br />A5TM Gg26 INCLUDING THE REFERENCE IN A5TM Gg26 5EGTION 6 TO 5EGTION XI.4.2 OF THE <br />APPENDIX <br />4. 4. 10. <br />INSTALLATION OF EXTERIOR LATHING $ FRAMING SHALL COMPLY TO ASTM G 1063 <br />PER FLORIDA RESIDENTIAL CODE R703.1.1 <br />4. 4. 11. <br />FIELD GUT ENDS, NOTGHES AND DRILLED HOLES OF PRE5ERVATIVELY TREATED HOOD <br />SHALL BE TREATED IN THE FIELD IN AGGORDANGE WITH ANPA M 4 <br />4. 3. FASTENERS AND TIE DOWNS : <br />4. 5. 1, <br />FASTENERS AND TIE DONNS SHALL GON515T OF BUT ARE NOT LIMITED TO <br />SHAPES, ANGLES, CHANNELS : ASTM A36/36M 08 Fy = 36 Ksi <br />ROUND METAL PIPE : ASTM A53/A53M-12, GRADE B Fy = 35 Ksi <br />SQUARE METAL TUBING : A5TM A500-13, GRADE B Fy = 4bKsl <br />HIGH STRENGTH BOLTS : ASTM A525-14 <br />MAGHINE BOLTS : GALVANIZED ASTM A307-12 <br />4. 5. 2• <br />SHEET METAL AGGE55ORIES SHALL CONFORM TO : Fy = 33K5iNITH GGO <br />GALVANIZED GOATING IN AGGORDANGE WITH A5TM A525-q3. <br />4. 5. 5. <br />NAILS SHALL GONS15T OF : COMMON HIRE NAILS HITH MINIMUM DIAMETER A5 <br />FOLLON5 : 8d = 0.131 ", IOd = 0.148", 12d = 0.148", 16d = 0.162". <br />4. 5. 4. <br />ALL FASTENERS AND TIE DONNS EMBEDDED IN GONGRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO RECEIVE AN ANT) -GORRO51VE GOATING BY MANUFACTURER <br />PRIOR TO INSTALLATION. <br />4. 5. 5. <br />ALL FASTENERS AND TIE DONN5 ARE TO PROVIDE THE UPLIFT GAPAGITY GALLED <br />FOR IN THE PLANS ARE A MINIMUM. <br />4. 5. 6. <br />ALL FASTENER TIE DONN5, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS <br />STRAPPING ARE TO BE INSTALLED IN AGGORDANGE WITH THE PLANS AND 5PEGIFIGATION5. <br />4. 5. 7. <br />CONCRETE EMBEDDED _'BOLTS USED FOR UPLIFT ARE TO BE NET SET PRIOR TO <br />INITIAL SET OF THE GONGRETE, SPAGING AND ALIGNMENT ARE TO BE IN AGGORDANGE <br />HITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. <br />4. 5. 8. <br />CONCRETE EMBEDDED TIE DONN5 USED FOR TRUSS AND HALL UPLIFT ARE TO BE <br />PLAGED AROUND EMBEDDED REINFORGING PRIOR TO OR NHILE PLAGING GROUT. <br />4. 5, q. <br />POST -INSTALLED ANGHOR5 INTO GONGRETE <br />1. P05T-INSTALLED ANCHORS SHALL ONLY BE USED HHERE SPECIFIED ON THE <br />GONSTRUGTION DOGUMENT5. THE GONTRACTOR SHALL OBTAIN APPROVAL FROM DANSGO <br />ENGINEERING, LLG PRIOR TO INSTALLING POST-IN5TALLEP ANCHORS IN PLACE OF <br />M1551NO OR MISPLACED CAST -IN -PLANE ANGHOR5. <br />2. CARE SHALL BE TAKEN IN PLAGING POST -INSTALLED ANCHORS TO AVOID CONFLICTS <br />HITH EXISTING REBAR. <br />3. HOLES SHALL BE DRILLED AND GLEANED IN ACCORDANCE HITH THE MANUFACTURER'S <br />PRINTED INSTRUGTION5 (MPII). <br />4. SUBSTITUTION REQUESTS FOR PRODUGT5 OTHER THAN THOSE SPECIFIED BELON SHALL BE <br />SUBMITTED BY THE GONTRAGTOR TO DE ALONG HITH GALGULATION5 THAT ARE <br />PREPARED $ SEALED BY A REGISTERED PROFESSIONAL ENGINEER. THE CALCULATIONS <br />SHALL DEMONSTRATE THAT THE SUBSTITUTED PRODUGT 15 CAPABLE OF AGHIEVING <br />EQUIVALENT PERFORMANGE (MINIMUM) VALUES OF THE 5PEGIFIED PRODUCT U51NG THE <br />APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(5) AS REQUIRED BY THE FLORIDA <br />BUILDING CODE. <br />5. PROVIDE PERIODIC, SPECIAL INSPEGTION FOR THRESHOLD BUILDINGS FOR ALL ADHESIVE <br />AND MEGHANIGAL ANGHOR5 PER THE PRODUCT'S FLORIDA PRODUCT APPROVAL. <br />6. GONTAGT MANUFAGTURER'5 REPRESENTATIVE FOR THE INITIAL TRAINING AND <br />INSTALLATION OF ANGHOR5 AND FOR PRODUGT RELATED QUESTIONS AND AVAILABILITY. <br />GALL SIMPSON STRONG -TIE AT (500) qqq-50gq. GALL HILTI AT (86b) 445-8827. <br />7. MEGHANIGAL ANCHORS SHALL HAVE BEEN QUALIFIED FOR USE IN AGGORDANGE WITH AGI <br />355.2 AND IGG-ES AGIg3 FOR GRAGKED AND UNGRAGKED GONGRETE RECOGNITION. <br />PRE -APPROVED MEGHANIGAL ANCHORS INGLUDE: <br />A) 5GREN: SIMPSON STRONG -TIE "TITEN-HD" OR HILTI "KHIK HUS-EZ" <br />B) EXPANSION: SIMPSON STRONG -TIE "STRONG -BOLT 2" OR HILTI "KHIK BOLT TZ" <br />8. ADHESIVE ANGHOR5 SHALL HAVE BEEN QUALIFIED FOR USE IN AGGORDANGE HITH AGI <br />355.4 AND IGG-ES AG308 FOR CRACKED AND UNGRAGKED CONCRETE RECOGNITION. <br />ADHESIVE ANCHORS SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF 21 <br />DAYS PER AGI 318-14 D.2.2. HOLES SHALL BE DRY AT THE TIME OF INSTALLATION. <br />ADHESIVES SHALL HAVE MAX. IN-SERVIGE SHORT-TERM TEMPERATURE OF I50°F, AND <br />MAX. IN-SERVIGE LONG-TERM TEMPERATURE OF I10°F (AGI 315 PA.2.0. PRE -APPROVED <br />ADHESIVE ANGHOR5 INGLUDE: <br />A) EPDXY: SIMP50N STRONG -TIE "SET-XP" OR HILTI "HIT -RE 500-SD" <br />B) FAST GURE: 51MP50N STRONG -TIE "AT-XP" OR HILTI "HIT-HY 200" <br />4.5. 10. <br />POST -INSTALLED ANGHOR5 INTO MASONRY <br />1. MEGHANIGAL ANGHOR5 INSTALLED IN SOLID -GROUTED GONGRETE MASONRY SHALL HAVE <br />BEEN QUALIFIED FOR USE IN AGGORDANGE HITH IGG-E5 AGOI OR AGIO(b. <br />PRE -APPROVED MEGHANIGAL ANGHORS INGLUDE: <br />A) 5GREN: SIMPSON STRONG -TIE "TITEN-HD" OR HILTI "KHIK HU5-EZ" <br />B) EXPANSION: SIMP50N STRONG -TIE "STRONG -BOLT 2" "NEDGE-ALL" OR HILTI <br />"KHIK BOLT 3" <br />2. ADHESIVE ANCHORS INSTALLED IN SOLID -GROUTED CONCRETE MASONRY SHALL HAVE <br />BEEN QUALIFIED FOR USE IN AGGORDANGE HITH IGG-E5 AG58. PRE -APPROVED <br />ADHESIVE ANCHORS INGLUDE: <br />A) EPDXY: SIMP50N STRONG -TIE "SET-XP" <br />B) FAST GURE: SIMP50N STRONG -TIE "AT-XP" OR HILTI "HIT -HIT' 10" <br />3. ADHESIVE ANCHORS INSTALLED IN HOLLOW CONCRETE MASONRY d UNREINFORGED CLAY <br />BRICK MASONRY SHALL HAVE BEEN QUALIFIED FOR USE IN AGGORDANGE HITH IGG-E5 <br />AG58 OR AG60, RESPECTIVELY. PRE -APPROVED ADHESIVE ANCHORS INGLUDE: <br />A) 51MP50N STRONG -TIE "SET" OR HILTI "HIT-HY 70" <br />4. THE APPROPRIATE SCREEN TUBE SHALL BE USED FOR ALL ADHESIVE ANCHORS <br />INSTALLED IN HOLLON GONGRETE MASONRY OR UNREINFORGED CLAY BRICK MASONRY <br />AS REQUIRED BY THE ADHESIVE MANUFACTURER. <br />4. 6. MICRO -LAM LUMBER: <br />4.6. I. <br />MIGRO- AM STRESS GRADES SHALL PROVIDE THE FO ONING MINIMUM PROPERTIES: <br />L LL LL <br />- <br />E 2,000,000 PSI <br />Fb = 2,g50 P51 <br />Ft = 1,850 PSI <br />Fr_ = 500 P51 (PERPENDIGULAR) <br />FG = 2300 (PARALLEL) <br />4. 1. STEEL: <br />Fv = 285 P51 <br />4.7. I. <br />INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED <br />STEEL ERECTOR. <br />4. 7. 2• <br />FABRICATE AND ERECT ALL STRUCTURAL STEEL IN AGGORDANGE HITH A.I.5.G. <br />"SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL <br />STEEL FOR BUILDINGS". <br />4. 7. 3. <br />STRUCTURAL STEEL: A5TM A36/36M 08. <br />4. 7. 4. <br />STEEL TUBING: A5TM A500-10, GRADE B. <br />4. 7. 5. <br />HELPED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET HELPS 3/16", ANS <br />GERTIFIED HELPERS. GERTIFIGATION PAPERS TO BE SUBMITTED UPON REQUEST. <br />4.1. b. <br />WHERE STEEL BEAMS ARE CONTINUOUS OVER GOLUMN5, PROVIDE WEB STIFFENER <br />PLATES ON EACH 51DE OF THE NEB, OF A THICKNESS EQUAL TO BEAM FLANGE <br />THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. <br />4. 1. 7. <br />THE STEEL FRAME 15 "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT <br />SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED GONNEGTIONS OR <br />ELEMENTS ARE IN PLACE. <br />4. 8. SOIL: <br />4. 8. I. THE FOOTING 15 DESIGNED BASE ON 2000 PSF 501L BEARING PRESSURE. <br />ONTRAGT HNER HA VERIFY SOIL BEARING PRE55URE OF THE PROPOSED SITE. <br />G OR/O SHALL L <br />4. 8. 2. ALL SOIL 15 TO BE GLEAN & P015ONED FOR TERMITES PER FBG bTH EDITION (2011) <br />RESIDENTIAL 5EGTION5 R318.1, R318.2, R318.3, a R318.7 <br />TERMITE PROTECTION - <br />PLANS MUST 5PEG I FY TYPE OF TERMITE TREATMENT <br />• SOIL CHEMICAL BARRIER METHOD <br />• OTHER TREATMENT - MUST SPECIFY PROPOSED METHOD AND SUBMIT DOCUMENTATION, NHIG <br />SUBSTANTIATES THE PROPOSED METHOD, 15 AN APPROVED TERMITE PROTECTION SYSTEM <br />OR METHOD. <br />IF CHEMICAL SOIL TERMITE TREATMENT 15 USED <br />I. FBG 105.11- "A PERMANENT 51ON NHIGH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE -INSPECTION AND TREATMENT GONTRAGT RENENAL SHALL BE <br />PROVIDED. THE SIGN SHALL BE POSTED NEAR THE HATER HEATER OR ELECTRIC PANEL" <br />2. GONDEN5ATE AND ROOF DOWNSPOUTS SHALL DISGHARGE AT LEAST 1'-0" ANAY FROM <br />THE BUILDING SIDE HALLS. <br />3. IRRIGATION/SPRINKLER 5Y5TEM5 INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT <br />BE INSTALLED HITHIN I'-0" OF THE BUILDING SIDE HALL. <br />4. FBG R303 - IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, <br />GLEARANGE BETHEEN EXTERIOR HALL GOVERIN05 AND FINAL EARTH GRADE ON <br />THE EXTERIOR OF A BUILDING HALL NOT BE LESS THAN 6 INCHES (152 MM) <br />EXCEPTIONS: <br />I. PAINT OR DEGORATIVE GEMENTITIOU5 FINISH LE55 THAN gg INGH (17.1 MM) THICK <br />ADHERED DIRECTLY TO THE MASONRY FOUNDATION 51DEHALL. <br />2. AGGE55 OR VEHICLE RAMPS NHIGH RI5E TO THE INTERIOR FIN15H FLOOR <br />ELEVATION FOR THE NIDTH OF 5UGH RAMPS ONLY. <br />3. A 4-INGH (102 MM) INSPECTION SPACE ABOVE PATIO AND GARAGE SLAB5 AND <br />ENTRY AREAS. <br />4. IF THE PATIO HAS BEEN 501L TREATED FOR TERMITES, THE FINISH ELEVATION MAY <br />MATGH THE BUILDING INTERIOR FINISH FLOOR ELEVATIONS ON MA50NRY <br />GON5TRUGTION ONLY. <br />5. MASONRY VENEERS CONSTRUCTED IN AGGORDANGE WITH SECTION R318.4. <br />5. R318.1.1 IF SOIL TREATMENT USED FOR SUBTERRANEAN TERMITE PREVENTION, THE INITIAL <br />CHEMICAL 501L TREATMENT IN51PE THE FOUNDATION PERIMETER SHALL BE <br />DONE AFTER ALL EXCAVATION, BAGKFILLING AND GOMPAGTION 15 COMPLETE. <br />6. R318,1.2 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, 501L <br />AREA DISTURBED AFTER INITIAL CHEMICAL SOIL TREATMENT SHALL BE RETREATED WITH <br />A GHEMIGAL SOIL TREATMENT INGLUDING SPACES BOXED OR FORMED. <br />7. R318.13 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, 5PAGE IN <br />CONCRETE FLOORS BOXED OUT OR FORMED FOR THE SUBSEQUENT INSTALLATION OF <br />PLUMBING TRAPS, DRAINS OR ANY OTHER PURPOSE SHALL BE CREATED BY USING <br />PLASTIC, OR METAL PERMANENTLY PLAGED FORMS OF SUFFICIENT DEPTH TO ELIMINATE <br />ANY PLANNED 501L DI5TURBANGE AFTER INITIAL GHEMIGAL SOIL TREATMENT. <br />8. R318.1.4 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />CHEMICALLY TREATED SOIL SHALL BE PROTECTED HITH A MINIMUM 6 MIL VAPOR <br />RETARDER TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OGGUR5 BEFORE <br />VAPOR RETARDER PLAGEMENT, RETREATMENT 15 REQUIRED. ANY WORK, INGLUDING <br />PLAGEMENT OF REINFORGING STEEL, DONE AFTER GHEMIGAL TREATMENT UNTIL THE <br />GONGRETE FLOOR 15 POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID <br />PENETRATING OR DISTURBING TREATED SOIL. <br />q. R318.1.5 IF SOIL TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />GONGRETE OVERPOUR OR MORTAR ACCUMULATED ALONG THE EXTERIOR FOUNDATION <br />PERIMETER SHALL BE REMOVED PRIOR TO EXTERIOR GHEMIGAL SOIL TREATMENT, TO <br />ENHANGE VERTIGAL PENETRATION OF THE GHEMIGALS. <br />10. R318.1.6 IF 501L TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, GHEMIGAL <br />SOIL TREATMENTS SHALL ALSO BE APPLIED UNDER ALL EXTERIOR GONGRETE OF GRADE <br />HITH I FOOT (305 MM) OF THE PRIMARY 5TRUGTURE 51DENALL5. ALSO, A VERTIGAL <br />GHEMIGAL BARRIER SHALL BE APPLIED PROMPTLY AFTER GON5TRUGTION 15 GOMPLETED, <br />INCLUDING INITIAL LANDSCAPING AND IRRGATION/SPRINKLER INSTALLATION. ANY SOIL <br />DISTURBED AFTER THE GHEMIGAL VERTIGAL BARRIER IS APPLIED SHALL BE PROMPTLY <br />RETREATED. <br />11. R315.17 IF A REGISTERED TERMITIGIDE FORMULATED AND REGISTERED AS A BAIT SYSTEM <br />15 USED FOR SUBTERRANEAN TERMITE PREVENTION, SECTION R318.1.1, THROUGH SECTION <br />R318.I.6b DO NOT APPLY; HOWEVER, A SIGNED GONTRAGT ASSURING THE INSTALLATION, <br />MAINTENANCE AND MONITORING OF THE BAITING SYSTEM FOR A MINIMUM OF FIVE YEARS <br />FROM THE 155UE OF THE GERTIFIGATE OF OCCUPANCY SHALL BE PROVIDED TO THE <br />BUILDING OFFIGIAL PRIOR TO THE POURING OF THE SLAB, AND THE SYSTEM MUST BE <br />INSTALLED PRIOR TO FINAL BUILDING APPROVAL. <br />IF THE BAITING SYSTEM DIRECTIONS FOR US REQUIRE A MONITORING PHASE PRIOR TO <br />INSTALLATION OF THE PESTIGIDE ACTIVE INGREDIENT, THE INSTALLATION OF THE <br />MONITORING PHASE COMPONENTS SHALL BE DEEMED TO CONSTITUTE INSTALLATION OF <br />THE SYSTEM. <br />12. R318.1.8 IF A REGISTERED TERMITIGIDE FORMULATED AND REGISTERED AS A HOOD <br />TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, 5EGTION5 R318.1.1 <br />THROUGH R318.1.6 DO NOT APPLY. APPLICATION OF THE HOOD TREATMENT TERMITIGIDES <br />SHALL BE AS REQUIRED BY LABEL DIREGTIONS FOR USE, AND MUST BE COMPLETED <br />PRIOR TO FINAL BUILDING APPROVAL. <br />13. R318.1 TERMITE PROTECTION. TERMITE PROTEGTION SHALL BE PROVIDED BY REGISTERED <br />TERMITIGIDES, INGLUDING SOIL APPLIED PESTIGIDE5, BAITING SYSTEMS, AND PESTICIDES <br />APPLIED TO HOOD, OR OTHER APPROVED METH005 OF TERMITE PROTECTION LABELED <br />FOR USE AS A PREVENTATIVE TREATMENT TO NEN CONSTRUCTION. SEE SECTION 202, <br />REGISTERED TERMITIGIDE. UPON COMPLETION OF THE APPLICATION OF THE TERMITE <br />PROTECTIVE TREATMENT, A GERTIFIGATE OF COMPLIANCE SHALL BE 155UED TO THE <br />BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE <br />FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR <br />THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT 15 IN AGGORDANGE HITH <br />RULES AND LAMS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AORIGULTURE AND <br />CONSUMER SERVICES." <br />14. R318.2 PENETRATION. PROTECTIVE SLEEVES AROUND PIPING PENETRATING CONCRETE <br />SLAB -ON -GRADE FLOORS SHALL NOT BE OF GELLUL05E-GONTAINING MATERIALS. IF <br />SOIL TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL <br />HAVE A MAXIMUM NALL THICKNESS OF 0.010 INGH (0.25 MM), AND BE SEALED HITHIN THE <br />SLAB USING A NON-GORROSIVE GLAMPING DEVICE TO ELIMINATE THE ANNULAR SPACE <br />BETHEEN THE PIPE AND THE SLEEVE. NO TERMITIGIDES SHALL BE APPLIED INSIDE THE <br />SLEEVE. <br />15. R318.3 GLEANING. CELLS AND CAVITIES IN MASONRY UNITS AND AIR GAPS BETHEEN <br />BRIGK, STONE OR MASONRY VENEERS AND THE STRUCTURE SHALL BE GLEANED OF ALL <br />NON -PRESERVATIVE TREATED OR NON -NATURALLY DURABLE HOOD, OR OTHER <br />GELLUL05E-GONTAININ6 MATERIAL PRIOR TO GONGRETE PLAGEMENT. <br />EXCEPTION: INORGANIG MATERIAL MANUFACTURED FOR GLOSING CELLS IN FOUNDATION <br />GONGRETE MASONRY UNIT GON5TRUGTION OR GLEAN EARTH FILL PLAGED IN CONCRETE <br />MASONRY UNIT VOIDS BELON SLAB LEVEL BEFORE TERMITE TREATMENT IS PERFORMED. <br />4. 8 .3. SOIL 15 TO BE COMPACTED TO q5% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-12e1 <br />NOTE: BORATE APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. OR <br />SENTRIGON SYSTEM TO BE USED <br />1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDIGTION "LIQUID BORATE OR <br />METHODS BOR-A-GOR" PRODUCT OR SENTRIGON SYSTEM, E HODS MUST BE DETERMINED AT PERMIT STAGE . <br />2) PRESSURE TREATED LUMBER THAT HAS BEEN GUT OR DRILLED THAT EXP05E5 UNTREATED PORTIONS OF <br />HOOP ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. <br />REQU I RED SAFETY OLAZ I NO IN HAZARDOUS LOCATIONS <br />56FETY GLAZING (RE: FRG R308.4) <br />R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE GON5IDEREP SPECIFIC, HAZARDOUS LOCATIONS <br />FOR THE PURPOSES OF GLAZING: <br />I. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SNINGING, SLIDING AND B1FOLD DOORS. <br />EXGEPTI ON5: <br />I. GLAZED OPENIN65 OF A SIZE THROUGH NHIGH A 3-INGH DIAMETER (76 mm) <br />SPHERE 15 UNABLE TO PASS. <br />2. DECORATIVE GLAZING. <br />2. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR SHALL BE CONSIDERED TO <br />BE A HAZARDOUS LOCATION HHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN 60 <br />INCHES (1524 MM) ABOVE THE FLOOR OR HALKING SURFACE AND IT MEETS EITHER OF THE FOLLOWING <br />CONDITIONS: <br />I. HHERE THE GLAZING IS HITHIN 24 INGHE5 (610 MM) OF EITHER SIDE OF THE DOOR IN THE PLANE OF <br />THE DOOR IN A GL05ED POSITION. <br />2. WHERE THE GLAZING 15 ON A HALL PERPENDICULAR TO THE PLANE OF THE DOOR IN A GL05ED <br />POSITION AND HITHIN 24 INCHES (610 MM) OF THE HINGE SIDE OF AN IN-5HINGING DOOR. <br />EXCEPTIONS: <br />I. DECORATIVE GLAZING. <br />2. HHERE THERE 15 AN INTERVENING HALL OR OTHER PERMANENT BARRIER BETHEEN THE DOOR AND THE <br />GLAZING. <br />3. WHERE AGGE55 THROUGH THE DOOR 15 TO A GLO5ET OR STORAGE AREA 3 FEET (q14 MM) OR LE55 IN <br />DEPTH. GLAZING IN THIS APPLICATION SHALL COMPLY WITH 5EGTION R308.4.3. <br />4. GLAZING THAT 15 ADJACENT TO THE FIXED PANEL OF PATIO DOORS <br />3. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE NINDON THAT MEETS ALL OF THE FOLLOWING <br />GONDITION5: <br />I. THE EXPOSED AREA OF AN INDIVIDUAL PANE IS LARGER THAN q SQUARE FEET 0.836m ; AND <br />2. THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18 INCHES (451 mm) ABOVE THE FLOOR; AND <br />3. THE TOP EDGE OF THE GLAZING 15 MORE THAN 36 INGHE5 (c114 mm) ABOVE THE FLOOR; AND <br />4. ONE OR MORE NALKINO SURFACE ARE HITHIN 36 INCHES (c114 mm), MEASURED HORIZONTALLY AND IN A <br />STRAIGHT LINE, OF THE GLAZING. <br />EXCEPTIONS: <br />I. DECORATIVE GLAZING. <br />2. WHEN A HORIZONTAL RAIL 15 INSTALLED ON THE AGGE55IBLE 51DE(S) OF <br />THE GLAZING 34 TO 38 INGHE5 (846 TO q(95) ABOVE THE NALKING <br />SURFACE. THE RAIL SHALL BE CAPABLE OF HITH5TANDING A HORIZONTAL <br />LOAD OF 50 POUNDS PER LINEAR FOOT (130 N/m) WITHOUT GONTAGTING <br />THE GLASS AND BE A MINIMUM OF 1 1/2" INCHES (38 mm) IN GROSS SECTIONAL HEIGHT. <br />3. OUTBOARD PANES IN INSULATING 0LAS5 UNITS AND OTHER MULTIPLE GLAZED PANELS NHEN THE <br />BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 mm) OR MORE ABOVE GRADE, A ROOF, NALKING <br />SURFACES OR OTHER HORIZONTAL (HITHIN 45 DEGREES (O.q7 RAP) OR HORIZONTAL) SURFACE <br />ADJACENT TO THE 6LA55 EXTERIOR. <br />4. ALL GLAZING IN RAILINGS REGARDLE55 OF AREA OR HEIGHT ABOVE A WALKING SURFACE. INGLUDED ARE <br />STRUCTURAL BALUSTER PANELS AND NON5TRUGTURAL INFILL PANELS. <br />5. GLAZING IN HALLS, ENGLO5URE5 OR FENCES CONTAINING OR FAGING HOT TUBS, SPAS, NHIRLPOOL5, <br />SAUNAS, STEAM ROOMS, BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR SHIMMING POOLS HHERE THE <br />BOTTOM EXF05ED EDGE OF THE GLAZING 15 LE55 THAN 60 INGHE5 (1524 MM) MEASURED VERTICALLY <br />ABOVE ANY STANDING OR WALKING SURFACE SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION, <br />THI5 SHALL APPLY TO SINGLE 6LAZING AND EACH PANE IN MULTIPLE GLAZING. <br />EXCEPTION: GLAZING THAT 15 MORE THAN 60 INCHES (1524 MM), MEASURED HORIZONTALLY AND IN A <br />STRAIGHT LINE, FROM THE HATER'S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL OR SHIMMING POOL OR <br />FROM THE EDGE OF A 5HONER, SAUNA OR STEAM ROOM. <br />(6. GLAZING HHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN 36 INGHE5 (c114 MM) ABOVE <br />THE PLANE OF THE ADJAGENT NALKING SURFACE OF STAIRWAYS, LANDINGS BETHEEN FLIGHTS OF STAIRS <br />AND RAMPS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. <br />EXCEPTIONS: <br />I. NHERE A RAIL 15 INSTALLED ON THE ACCESSIBLE 51DE(S) OF THE GLAZING 34 TO 38 INCHES (864 TO <br />q(95 MM) ABOVE THE HALKING SURFAGE. THE RAIL SHALL BE CAPABLE OF HITH5TANDIN0 A <br />HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT (130 N/M) HITHOUT GONTAGTING THE GLASS AND <br />HAVE A GROSS-SEGTIONAL HEIGHT OF NOT LE55 THAN 1 1/2 INGHE5 (55 MM). <br />2. GLAZING 36 INCHES (q14 MM) OR MORE MEASURED HORIZONTALLY FROM THE HALKING SURFACE. <br />7. GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A 5TAIRNAY HHERE THE GLAZING 15 LESS THAN <br />36 INGHES (c114 MM) ABOVE THE LANDING AND WITHIN A 60-INGH (1524 MM) HORIZONTAL ARG LESS THAN <br />100 DEGREES FROM THE BOTTOM TREAD N051NO SHALL BE GON5IDERED TO BE A HAZARDOUS LOCATION. <br />EXCEPTION: THE GLAZING 15 PROTECTED BY A GUARD GOMPLYINO WITH SECTION R312 AND THE PLANE OF <br />THE GLASS 15 MORE THAN 18 INCHES (457 MM) FROM THE GUARD. <br />NOTE: <br />IT 15 THE GONTRAGTOR5 RESPONSIBILITY TO REVIEW ALL DRANIN05 BEFORE GON5TRUGTION BEGINS. <br />DAN5G0 ENGINEERING, LLC, 15 RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJEGT ONLY. ANY <br />DISGREPANGY BETHEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWINGS, <br />GONTRAGTOR5' BUILDING METHODS, AND THESE 51ONED AND SEALED DRANINOS MUST BE BROUGHT TO THE <br />ATTENTION OF FLORIDA DESIGN SOLUTIONS, ING. PRIOR TO THE GOMMENGEMENT OF GON5TRUGTION. <br />ATTENTION: GHEMIGAL GHANGES IN PRE55URE TREATED HOODS <br />AS OF DEGEMBER 315T, 2003, GHROMATED COPPER ARSENATE (GGA-G) HILL NO LONGER BE PRODUCED FOR <br />RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL NEW PRE55URE TREATED HOOD ALTERNATIVES HAVE <br />BEEN GREATED TO REPLAGE GGA-G. MANY OF THE NEW PRE55URE TREATED HOODS USE GHEMIGALS THAT <br />ARE GORRO51VE TO STEEL. IT 15 THE GONTRAGTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF HOOD <br />TREATMENT AND TO 5ELEGT APPROPRIATE GONNEGTORS THAT RESIST CORROSION. FOR EXAMPLE, AGQ-C, <br />AGO-D, GBA-A, OR GA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM <br />BORATE (5BX) DOES NOT. <br />NORST GASE DES I G N PRESSURE TABLE <br />BUILDING DATA <br />WIND SPEED 140 MPH (Vasd 108 MPH) <br />WIND EXPOSURE -- 'C' (FRG R301) <br />INTERNAL PRE55URE COEFFICIENT= +/- 0.10 ENCLOSED BLDG) <br />DE51GN WIND PRESSURE: <br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br />0 END ZONE 15 ONLY WITHIN 5'-0' <br />OF ALL EXTERIOR BUILDING CORNERS <br />WINDOWS AND DOORS (A51D PRESSURES) <br />140 MPH + 25L P5F / - 34.3 PSF (END) UNLE55 NOTED ON FLOOR PLANS <br />+ 25b P5F / - 21.1 PSF ( INTERIOR) UNLE55 NOTED ON FLOOR PLANS <br />GARAGE DOORS (A51D PRESSURES) <br />SINGLE Bxl + 22.3 P5F / - 25.3 PSF <br />DOUBLE 16x1 + 21.4 P5F / - 23.8 PSF <br />g.:�ssm <br />'rs�:sx <br />DAN SCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.danscoengineedng.com <br />CA 25948 <br />i <br />O <br />O <br />N <br />Z Lu <br />OLn^ <br />kO CD <br />Qt~CD <br />Z <br />/IM� <br />(' <br />_jLn <br />�LLLILL^ <br />Ln <br />z <br />HaaL+� <br />00 <br />H H <br />W_j <br />Lu 3 <br />O <br />O <br />�O <br />U <br />i2 <br />LJJ uj <br />W <br />Lu <br />ui cn <br />O V) <br />J <br />QL Im <br />z <br />m <br />Q O <br />m <br />O <br />w <br />z U <br />QZz � <br />O <br />� <br />2 <br />V) <br />ZD <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY W11H <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd = 108MPH), 3 SEC. GUST, <br />EXPOSURE "C' ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT=±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHIS DRAWINGONLY. <br />©M19 LENNAR CORP,-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />02019- THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CLIENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIBITED. <br />REVISION: <br />DATE <br />DESCRIPTION <br />UPDATED CONNECTION <br />06.08.18 <br />1.01 CROSS-REFERENCE TABLE <br />AND STAIR STRAP <br />01.09.19 <br />1.02 ROOF UNDERLAYMENT REV. <br />02.11.19 <br />1.03 UPDATED CONNECTION <br />CROSS-REFERENCE TABLE <br />VERSION NO. lri10, / 02.11.19 <br />i <br />y <br />a <br />i?01 <br />Cli J­,",, <br />Lm <br />Lu �z <br />m J <br />z O <br />J Lu <br />Q w = U <br />W C�LO �N <br />H Q� =N <N <br />W Lu co 2� 00 <br />W :D* >_* w* <br />Z 1-4Ld <br />Q LLi = LL <br />W ❑ ❑ <br />SHEET TITLE: <br />STRUCTURAL NOTES <br />SHEET INFORMATION: <br />JOB NO.: 390444 <br />DATE ISSUED: 04.04.19 <br />DRAWN BY: LF <br />REVIEWED BY: TH <br />SN <br />