My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6356 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6356 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:38:23 PM
Creation date
2/19/2025 10:58:45 AM
Metadata
Fields
Template:
Building Plans
Street #
6356
Location
Cobble Bliss St
Contractor
Lennar Homes LLC
Building Plans - Permit #
21425
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TYP @ 2 STORY <br />J <br />S6 <br />50'-0" <br />4'-2" <br />13'-11" <br />5'-2" <br />18'-4" <br />8'-5" <br />B <br />OH <br />6068 S.G.D. <br />TEMP. <br />OD <br />35-SH <br />35-SH <br />( <br />EGRESS <br />3ACPAD <br />�° <br />1 <br />1 <br />F M I LY R M o PLUMING <br />�� STACK <br />8'-8" CLG. <br />CARPET <br />-6$' 2'-1" 80T-6„ 6'-102" <br />I <br />(3)2X4#2 N <br />M <br />I SPF STUDS <br />-42"SLOPING =,N <br />HAL WALL CO <br />I I I I I I I I <br />(4) 2 X 4# 2 UP 16R I I I I I I I I I <br />SPF STUDS I I I I <br />I I I I I I I I <br />G.T. - 1.! 21 31 41 51 61 71 81 91101 11 <br />2 X 4 # 2 SPF EDGE OF SLAB 2" CC <br />STUDS @ 16" O.C. BEYOND WALL S3 <br />(3)2X4#2 <br />SPF STUDS <br />CC <br />S3 <br />HDR AT 81=0" <br />__ 2X4#2SPF <br />- --- - <br />STUDS @ 16" O.C. <br />-LN <br />-0" 7 ' 10'-7$" <br />00 <br />¢I <br />�I <br />ECC <br />( <br />S <br />1'-102 <br />,o FIBERGLASS <br />SURROUND <br />O TB <br />TP <br />° NA - <br />p <br />V: <br />�o w <br />Z 2068 <br />r BI-FOLD <br />I <br />I <br />I S2 <br />�6'�p <br />H1 <br />(3) 2 X 4# 2 <br />SPF STUDS <br />2 X 4 # 2 <br />F STUDS <br />3 CAR <br />GARAGE <br />8'-8" CLG. <br />---------- <br />S <br />BEDROOM 2 <br />8'-8" CLG. <br />CARPET <br />�t <br />2668 �2) 2068 <br />I -FOLD <br />AHU <br />W.I.C. I m <br />CLG. Er <br />L----- -- -J <br />R& <br />CC <br />=� S3 W.H. <br />STUDS @ /2X4#2S16" O.C. <br />0( <br />BUILDER TO PROVIDE <br />APPLIANCE <br />PROTECTION WHEN <br />REQUIRED PER FBC <br />- <br />60 <br />--- -------- --- <br />2'-92'- 8'-8 -, <br />T <br />CAFE <br />8'-8" ' CLG. <br />TILE <br />2'-0" <br />I <br />I m <br />I <br />O uJ <br />LU <br />z <br />O 1 <br />I <br />I" <br />'APT, <br />I <br />I <br />°i <br />o <br />3 <br />z <br />Cl)------ <br />II �-- <br />D.W. III <br />III <br />L_-JI I <br />I I <br />O 1 1 <br />I I <br />I I <br />El 1 I <br />II <br />•..••II <br />I-- <br />r <br />o <br />KITCHEN- <br />- <br />8'-8" CLG.Cl) <br />TILE <br />-� ---� ---� -' <br />N <br />P <br />I <br />1 <br />I <br />( <br />BI-FOLD <br />°° <br />D <br />=W <br />'-8" <br />=W <br />`'° <br />L'° <br />"'ifl <br />TILE <br />�`O <br />5-SH <br />16" DEEP <br />10'-10" <br />51 <br />2 <br />2'1s <br />N <br />z' <br />I I <br />FLEX 00 <br />I I <br />8'-8" CLG. ¢1 <br />CARPET o� 1 <br />1 00 <br />NOTE: FINISHED WALLS <br />TO BE FLUSH. VERIFY IN <br />FIELD,IPI <br />25-SSH 25-SH <br />EGRESS <br />I <br />2' 10" 6,_6" 5'-2" 1'-2" <br />Y <br />8'- "C G. <br />ILE <br />O M <br />4'-6" <br />I <br />------------- I <br />I - I I <br />I I <br />I I I <br />D I I <br />I S3 I I <br />I I <br />I------------------- <br />I---------------H--- <br />I 8 x 7 OVERHEAD DOOR I <br />52' <br />I <br />I <br />I <br />I <br />I <br />16 x 7 OVERHEAD DOO <br />----------- <br />- - - - - - - - - - - <br />O <br />2' <br />0" <br />O 2FLOOR <br />8'-0" ND. <br />ABV. <br />Z'-0" " <br />K 16'-0" <br />2'-0" <br />I <br />1 <br />13'-8" <br />6-8" <br />o <br />12'-0" <br />18'-8" <br />ENTRY <br />CLG--- <br />GARAGE <br />--- - <br />- - - - - - - - - <br />4" <br />5'-4" <br />'4" <br />5'-8" <br />'-0" <br />5'-4" <br />-0" <br />12" SQ. CMU COLUMN <br />W/ (2) #5, FULLY <br />GROUTED (TYP.) <br />29'-8" <br />20'-4" <br />50'-0" <br />TYP @ 2 STORY <br />J <br />S6 <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 91/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />HS <br />(2) - 1 3/4" X 7 1 /4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />FIRST FLOOR PLAN-B <br />SCALE: Y4'=1'-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302:5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.G. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />K-A <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />�D <br />+28.3 / -36.4 <br />OE <br />+26.6 / -28.0 <br />0 <br />+26.6 / -32.2 <br />GO <br />SEE SIN SHEET HH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />IIIIIIIIIIIIIII�t � rr:: <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "B" <br />1ST FLOOR LIVING AREA <br />1358 <br />2ND FLOOR LIVING AREA <br />1996 <br />LIVING TOTAL <br />3354 <br />GARAGE <br />644 <br />ENTRY <br />137 <br />TOTAL AREA <br />4135 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />jR-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />0 <br />n 0 1 <br />U <br />M <br />_ o <br />Z <br />z <br />�C <br />U) z <br />cn <br />a--+ w <br />t"� p <br />.O <br />w <br />Mf <br />V) <br />� <br />o 0 <br />m <br />- LLJ <br />8 <br />N <br />�oM <br />' - <br />m <br />O o 0 <br />U N <br />LL 000 <br />-C 0 <br />C O <br />Q rn <br />co 0.O <br />U-) R: <br />rn Q o <br />B D® <br />Nc <br />N10 <br />U) O <br />N � <br />Z W M�o� H z <br />LU mLL <br />W V ¢ <br />Z <br />N <br />E, <br />LL <br />W 401; . <br />OW U_ <br />s <br />' 4 <br />.FIIS Q <br />CI lot,• rG. rn <br />r <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />OZ <br />Q f <br />�F <br />uiz�0 <br />U <br />z w Q <br />� <br />z <br />2 LU <br /><^ <br />Lu <br />z <br />rr <br />z <br />r U <br />a <br />o <br />1..1. <br />�- <br />O <br />g Z <br />g <br />O <br />o <br />M <br />U) <br />J LU <br />U-) <br />M <br />opZo <br />a�o <br />O <br />< <br />ZazL <br />a a <br />Q <br />00 <br />E <br />Z <br />N <br />Lu <br />J <br />Lr) <br />r 4 <br />Ll.j <br />!;- <br />¢ <br />tj j <br />Q <br />z <br />Q Z <br />o � a <br />P t- I- <br />z <br />M <br />ILn <br />N* <br />z <br />CY Z <br />co <br />4Z <br />T <br />J 0 <br />O <br />[r4 <br />rn <br />,-4 <br />(a_ <br />V) <br />o <br />SCALE : AS NOTED <br />DATE : 4/5/2019 <br />TECH: JBERCHAL <br />VERSION NO. 3ol <br />SHEET NO. <br />1.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.