ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />#14 copper to lights & outlets <br />1 <br />20000 AMP #12 copper to 20 amp ckts <br />1110-2 copper to WH <br />#10-3 copper to Dryer <br />MAIN <br />O2/0 or 410 SER Alu <br />200 amp <br />150 amp =Y <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground UPAD <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER � WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />,l <br />t <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�{JeD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />WP71_ <br />ELECTRIC PANEL <br />_Mai <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />�7K - 27� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />M. <br />WP <br />GFI <br />CAFE <br />►yT AS , <br />1 <br />ITCHE <br />;REF. <br />—a.L---2L_--1L- <br />FLEX <br />12ROUGH-IN FOR <br />OPT. CLG. FAN/ <br />\sLIGHTPRE-WIRE <br />ENTRY <br />ENTRY LIGHT - <br />AS PER SPECS <br />FAMILY RM <br />1 ROUGH -IN FOR <br />1 OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />WP DISC. AC PAD <br />GFI <br />A <br />BEDROOM 2 <br />IN�111W12 <br />L <br />FOR <br />MV1LIGHT PRE -WIRE <br />S.D. <br />OWN <br />% 1 �m - <br />I I I I I I T Y� W <br />B 7!,"' <br />I I I �� GFI @ 44" (nH. <br />oll <br />A.F.F. <br />13 101 11 I I � O <br />/ I <br />/ 1 <br />Z w <br />F- <br />/ GARAGE <br />LIGHT AS ; 0 U <br />PER SPECS 1 Ct <br />U <br />3 CAR ; W W <br />GARAGE % GARAGE ' <br />LIGHT AS ♦ / <br />PER SPECS ��i <br />GFI FOR..—�•'� � <br />GAR. DOOR �� u- <br />PREWIRE 0 <br />Z� <br />OLL <br />! ~ <br />=1 @ 44" / GFI FOR <br />A.F.F. 6 GAR. DOOR <br />PREWIRE I I <br />r------------------I I I <br />I I I I <br />I I I I <br />I I I I <br />I <br />I I I I <br />1 I I <br />I I I I <br />I I <br />I I ------------- <br />------------------ <br />II ------------------------------- <br />I I <br />C] IC�IIL. <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN - <br />SCALE: %4"=1' <br />I � <br />0 19 <br />� o <br />o <br />Z CID <br />Z <br />Q <br />d <br />E3 <br />0 <br />V, CJ <br />0 <br />( <br />.0 <br />F— <br />o <br />m N <br />W E <br />0° <br />V <br />a 01 <br />N c'7 <br />m M <br />N � M <br />V1 <br />0 0 0 <br />U <br />< <br />o <br />tiZco <br />Q CDQ <br />o <br />B D. <br />N C H D,C <br />f�7 <br />]*IT <br />_ G� <br />y g M <br />� fgz <br />W MN � z° <br />t• ._ U_ CO a <br />rn o 14 4 <br />LU c- N a W <br />W U¢am o a <br />Z. <br />Z 0. a¢ a 1? <br />Z ETw <br />A <br />MEN. <br />LU aN Q M A <br />O v V O <br />IJ Li <br />WWW.FDSENG.COM <br />0 <br />CV <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0€0 <br />a� <br />Za <br />Zap <br />�t <br />p=oo <br />J <br />Z� <br />CL <br />J <br />1;- z <br />J <br />Qn.awa�°� <br />m <br />Zo <br />I..L. <br />>< v <br />f z <br />Z <br />-0 <br />`� <br />_3 <br />w <br />o <br />> <br />��.. <br />QO <br />V <br />� <br />M <br />M <br />o <br />o <br />J <br />U— <br /><.o6 <br />Z <br />VO0a <br />N <br />Q <br />< a� <br />W <br />a< <br />Q <br />Cal <br />Z <br />Z <br />dam' <br />N <br />° <br />c'gt <br />JLn <br />r-I <br />W <br />Z <br />W <br />Z <br />5j<z° <br />¢ <br />$~o <br />�`Z <br />�oE <br />0o <br />N <br />z <br />U <br />¢ w <br />� <br />C3 <br />_ <br />r--I <br />0- <br />U') <br />o <br />SCALE : AS NOTED <br />DATE : 4/5/2019 <br />TECH: JBERCHAL <br />VERSION NO. 3ol <br />SHEET NO. <br />4.1 <br />