SPEC I F I GAT I ON5 <br />I. I. CONSTRUCTION <br />I. I. I. AGI 3I8-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />I. I. 2. A5GE5/AGI 530-13, TM5 402-16 4 ASGE6/AGI 530.1-13, TM5 602-16 <br />SPECIFICATIONS FOR MA50NRY STRUCTURES. <br />I. I. 3. A5TM G270-12a, C416-10, AND Gq0-14 SPECIFICATIONS FOR MASONRY STRUCTURES <br />I. I. 4. NATIONAL DESIGN SPECIFICATIONS (ND5) FOR WOOD CONSTRUCTION, 2015 EDITION, AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />I. 1. 5. FLORIDA RESIDENTIAL CODE (FRG), FLORIDA BUILDING CODE (FBG), bth EDITION (2011) <br />I. I. 6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN <br />INSTITUTE OF STEEL CONSTRUCTION, (AISG) <br />1. 1. 1. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED HOOD TRUSSES" BY THE <br />TRU55 PLATE INSTITUTE TPI 1-14. <br />1.2. DE51ON : <br />I. 2. I. AGI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />I. 2. 2. A5GEWAGI 530-13, TM5 402-I6 4 A5GEb/AGI 530.1-13, TM5 602-16 <br />SPECIFICATIONS FOR MA50NRY STRUCTURES. <br />I. 2. 3. A5TM G210-12a, G416-10, AND GqO-14 SPECIFICATIONS FOR MASONRY STRUCTURES <br />I. 2. 4. NATIONAL DE516N 5PEGIFIGATION5 (ND5) FOR HOOD CONSTRUCTION, 2015 EDITION, AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />I. 2. 5. PLYWOOD DE51ON SPECIFICATIONS (APA) <br />I. 2. 6. FLORIDA RESIDENTIAL CODE (FRG), FLORIDA BUILDING CODE (FBG), bth EDITION (201-7 <br />J <br />I. 3. 5HOP DRAWINGS : <br />I. 3. I. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DE51ON PLANS BY OTHERS <br />DURING THE PREPARATION OF SHOP DRAHIN65 WITHOUT WRITTEN APPROVAL FROM <br />THE ENGINEER OF RECORD. <br />1. 3. 2. ALL SHOP DRAHIN65 ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO <br />THE COMMENCEMENT OF CONSTRUCTION. <br />ALL ROOF AND FLOOR TRU55 SHOP DRAHING5 ARE TO BE SIGNED AND SEALED BY A FLA. <br />REG. PE. AND SHALL INCLUDE : DRANIN05 AND CALCULATIONS, REACTIONS AND BEARING <br />POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRU55 MEMBERS. <br />2. DE51 6N LOADS <br />TH15 STRUCTURE HAS BEEN PE5I6NED IN AGGORDANGE WITH THE 6th ED. (2011) FLORIDA <br />BUILDING GODE, RE51DENTIAL <br />BUILDING CATEGORY: II <br />2.1. DEAD LOADS: <br />ROOF <br />TILE (TG=15P5F, BG=IOPSF) 25PSF <br />ASPHALT SHINGLE (TG=1P5F, BG=IOP5F) I1PSF <br />METAL (TC=IOP5F, BC=IOP5F) 20P5F <br />FLOOR <br />TILE (GERAMIG, 1/2" MORTAR BED) 25P5F <br />CARPET OR HOOD 15P5F <br />2. 2. L I VE LOAD5 : <br />ROOF <br />20P5F <br />FLOOR <br />ONE- AND TWO-FAMILY DHELLIN65 <br />UNINHABITABLE ATTIC, NO STORAGE <br />IOPSF <br />UNINHABITABLE ATTIC, LIMITED STORAGE <br />20P5F <br />HABITABLE ATTICS, SLEEPING AREAS <br />3OP5F <br />OTHER <br />40PSF <br />EXTERIOR DECKS <br />SAME AS OCCUPANCY SERVED <br />RAILING - NONGONGURRENT <br />50PLF OR 200LB <br />LIVE LOAD REDUCTIONS <br />PER CODE <br />2. 3. ROOF SNON LOAD DATA: <br />GROUND 5NOH LOAD, Pg = WA <br />2.4. HIND LOA05 : <br />BASIC HIND SPEED, V (3-5EG. GUST) <br />14OMPH (Va5d=108MPH) <br />HIND EXP05URE <br />G <br />INTERNAL PRESSURE COEFFICIENT <br />+/-O.IS <br />G8G PE51ON PRESSURE <br />SEE PLAN <br />HIND BORNE DEBRIS PROTEGTION <br />5HUTTER/IMPAGT GLA55 <br />2, 5. SEISMIC, DESIGN DATA: <br />SEISMIC IMPORTANCE FACTOR, le <br />1.0 <br />SEISMIC RISK CATEGORY <br />II <br />MAPPED 5RA, 55, 51 <br />N/A <br />517E CLASS <br />A <br />DESIGN 5RC, 5D5, 5DI <br />WA <br />SEISMIC DE516N GATEGORY <br />WA <br />BASIC 5FR5 <br />MASONRY HALLS <br />DESIGN BASE SHEAR, (UNFAGTORED) <br />WA <br />SEISMIC RESPONSE COEFFICIENT, G5 <br />WA <br />RESPONSE MODIFICATION FACTOR, R <br />N/A <br />ANALY515 PROCEDURE <br />ELF <br />2. 6. FLOOD DESIGN DATA: <br />DATUM NAVD88 <br />FLOOD ZONE ..X.. <br />BASE FLOOD ELEVATION: WA <br />LOWEST PROPOSED FLOOR ELEVATIONS WA <br />3. DEFLECTIONS: <br />LIVE LOAD L/360 <br />TOTAL LOAD L/240 <br />4. MATERIALS <br />4.1. RE I NFORG I NO STEEL <br />4. I. I. REINFORCING STEEL SHALL BE A5TM A615/A615M-Oc1 GRADE 40, f'y = 40 K51 <br />4. 1. 2• LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 15". <br />4. I. 3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF <br />EACH BAR EXCEPT HHERE THE COVER DIMENSION 15 SHOWN TO THE FACE OF THE CONCRETE. <br />4. I. 4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. <br />4. I. 5. REINFORCING MECHANICAL GOUPLER5 ARE TO DEVELOP 125 % OF THE REQUIRED <br />YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. <br />4. I. 6. DE51ON COVER REQUIREMENTS : <br />G-I-P CONCRETE FORMED AGAINST EARTH 3.. <br />G-I-P CONCRETE EXP05ED TO EXTERIOR : 2" <br />G-I-P CONCRETE NOT EXPOSED <br />GROUT FILLED MASONRY : 34" <br />HELPED WIRE FABRIC (HHF): A1064/A1064M-I6a <br />4. I. 8. DETAIL REINFORCEMENT IN ACCORDANCE WITH AGI 315-LATEST EDITION. <br />4. 2. GONGRETE : <br />4. 2. I. <br />CONCRETE TYPE <br />MIN. 28 DAY <br />DESIGN (f'c) <br />MODULES OF <br />ELASTICITY <br />DESIGN (E) <br />G-I-P CONCRETE (NORMAL HEIGHT) <br />2,500 P51 <br />2050 K51 <br />6-1-P CONCRETE (NORMAL HEIGHT) HERNANDO CO. ONLY <br />3,000 P51 <br />3,12 K51 <br />G-I-P GROUT <br />3 00 P51 <br />5,122 K51 <br />4. 2. 2. <br />CONCRETE SHALL CONSIST OF I" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP <br />BETWEEN 6" AND 1" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL <br />CRITERIA. <br />4. 2. 3. <br />GROUT SHALL CONSIST OF PEA ROCK (3/5" MAXIMUM AGGREGATE) CONCRETE MIX <br />WITH SLUMP BETHEEN 8" AND 10" AT TIME OF PLACEMENT. SEE 5PECIFIGATION5 FOR <br />ADDITIONAL CRITERIA. <br />4. 2. 4. <br />CONSTRUCTION JOINTS HILL BE PERMITTED <br />4. 2. 5• <br />METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN <br />ACCORDANCE WITH THE SPECIFICATIONS AS STATED. <br />4. 2. 6. <br />EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR HALKHAY5 4 DRIVEHAY5) <br />3 1/2" MIN. THICKNESS H/ MIN. REINFORCEMENT OF 6.0 x 6.0 H/ 1.4 x 1.4 HHF <br />IN TOP OF 1-1/2" OF SLAB. FIBER MESH PER DE51ON MIX MAY BE USED I.L.O. HHF <br />CONTRACTORS DISCRETION. <br />4. 2. 1. <br />CONCRETE PLACEMENT PRACTICES SHALL BE IN ACCORDANCE H/ ALL <br />AGI- MGP 2011 STANDARDS. <br />4.3. GONGRETE MASONRY : <br />4. 3. 1. <br />FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. <br />4. 3. 2. <br />LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE A5TM Gq0-14, TYPE 11 <br />NON-MO15TURE CONTROLLED. <br />4. 3. 3. <br />ALL CELLS d CAVITIES BELOW GRADE WILL BE FILLED H/ CONCRETE IN ALL STEM HALLS <br />4. 3. 4. <br />THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 2,000 P51 MINIMUM <br />4. 3. 5. <br />METHOD OF CONCRETE MASONRY PLACEMENT AND GON5TRUGTION SHALL BE <br />CONDUCTED IN AGGORDANCE HITH THE SPECIFICATIONS AS STATED. <br />4. 3. 6. <br />MORTAR SHALL BE TYPE "S" FOR ALL MA50NRY CONSTRUCTION. <br />4. 3. 1. <br />MASONRY ROUGH OPENING MAY VARY IN THE GROSS SECTION DIMENSION OR ELEVATION <br />DIMENSION SPECIFIED ON THE APPROVED PLANS FROM -1/4" TO +1/2" PER SECTION R606.3.1.1 <br />4.4. STRUGTURAL LUMBER : <br />4. 4. 1.1. <br />INTERIOR LOAD BEARING HALLS 5PF STUD OR BETTER, fb = 615 P51, E = 1200 K51 <br />ALL EXTERIOR FRAMING 5PF #2 OR BETTER, fb = 815 P51, E = 1,40OK51 <br />4. 4. 1.2. <br />ALL FRAME HALLS TO BE CONSTRUCTED U51N6 5PF , <br />STUD QUALITY OR BETTER, UNLE55 NOTED OTHERHI5E <br />4. 4. 2. <br />ALL PLYWOOD USED FOR EXTERIOR APPLIGATION5 <br />SHALL BE APA RATED SHEATHING EXP I U.N.O. <br />4. 4. 3. <br />ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND <br />SHEAR HALLS SHALL BE APA RATED SHEATHING EXP I U.N.O. <br />4. 4. 4. <br />IF 05B BOARD 15 TO BE USED IN PLACE OF PLYWOOD 15 TO HAVE 51MILAR OR <br />GREATER 5EGTION PROPERTIES. <br />4. 4. 5. <br />ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN <br />CONTACT WITH CONCRETE 15 TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />4. 4. 6. <br />HHEN PRE ENGINEERED TRUSSES ARE GALLED FOR ON THE PLANS THE <br />MANUFACTURER 15 TO SUBMIT SHOP DRAHIN65 TO THE ENGINEER OF RECORD. <br />4. 4. 1. <br />DESIGN, FABRICATE AND ERECT HOOD TRUSSES IN ACCORDANCE WITH THE "DE51GN <br />SPEGIFIGATION FOR LIGHT METAL PLATE CONNECTED HOOD TRU55E5" BY THE <br />AN51/TPI 1-14, BC51 2013 <br />4. 4. 8. <br />UNTREATED HOOD SHALL NOT BE IN DIREGT CONTACT WITH CONCRETE. SEAT PLATES <br />SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. <br />4. 4. q. <br />ALL EXTERIOR FRAME HALLS SHALL BE STUCCO FINISH AND SHALL BE APPLIED IN STRICT <br />ACCORDANCE WITH THE FRG SECTION R103.1.2 AND WITH A5TM Gg26 INCLUDING THE <br />REFERENCE IN A5TM Gg26 SECTION 8 TO 5EGTION XI.4.2 OF THE APPENDIX - 1/8" TOTAL <br />THIGKNE55 APPLIED IN THREE LAYERS (3/8" - 3/8" - V5") OVER METAL LATH OVER HATER <br />RESISTIVE BARRIER. THE HATER RE515TIVE BARRIER SHALL INCLUDE A WATER-RE515TIVE <br />VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO TWO <br />LAYERS OF GRADE D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED <br />INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE AND <br />SHALL BE ATTACHED DIRECTLY TO THE 5HEATHING OVER FLASHING INSTALLED IN <br />ACCORDANCE HITH THE APPLICABLE BUILDING GODE AND MANUFACTURER'S <br />SPECIFICATIONS. CURING TIME FOR 3-COAT STUCCO, EACH GOAT SHALL BE KEPT IN A M015T <br />CONDITION FOR AT LEAST 48 HOURS PRIOR TO THE APPLICATION OF THE NEXT GOAT. THE <br />2ND GOAT SHALL NOT BE APPLIED 50ONER THAN 48 HR5 AFTER APPLICATION OF THE I5T <br />GOAT. THE FIN15H GOAT SHALL NOT BE APPLIED 50ONER THAN 7 DAYS AFTER THE <br />APPLICATION OF THE 2ND GOAT. UNLE55 APPLICATIONS INSTALLED IN ACCORDANCE HITH <br />A5TM Gg26 INGLUDING THE REFERENCE IN A5TM Gg26 5EGTION 6 TO SECTION XI.4.2 OF THE <br />APPENDIX <br />4. 4. 10, <br />INSTALLATION OF EXTERIOR LATHING 6 FRAMING SHALL COMPLY TO A5TM G 1063 <br />PER FLORIDA RESIDENTIAL CODE R1033.I <br />4. 4. I1. <br />FIELD GUT ENDS, NOTCHES AND DRILLED HOLES OF PRE5ERVATIVELY TREATED WOOD <br />SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AHPA M 4 <br />4. 5. FASTENERS AND TIE DONN5 : <br />4. 5. I. <br />FA5TENER5 AND TIE DOHN5 SHALL CONSIST OF BUT ARE NOT LIMITED TO <br />SHAPES, ANGLES, CHANNELS : A5TM A36/36M OS Fy = 36 KBI <br />ROUND METAL PIPE : A5TM A53/A53M-12, GRADE B Fy = 35 K51 <br />SQUARE METAL TUBING: A5TM A500-13, GRAPE B Fy = 461<51 <br />HIGH 5TREN6TH BOLTS : A5TM A325-14 <br />MACHINE BOLTS : GALVANIZED A5TM A301-12 <br />4. 5. 2. <br />SHEET METAL ACCESSORIES SHALL CONFORM TO : Fy = 331<9IHITH bqO <br />GALVANIZED GOATIN6 IN ACCORDANCE WITH A5TM A525-cO. <br />4. 5. 3. <br />NAILS SHALL GON515T OF : COMMON HIRE NAILS WITH MINIMUM DIAMETER AS <br />FOLLOH5 : bd = 0.131 ", I Od = 0.148", 12d = 0.145", I bd = 0.162". <br />4. 5. 4. <br />ALL FA5TENER5 AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO RECEIVE AN ANTI-GORROSIVE GOATIN6 BY MANUFACTURER <br />PRIOR TO INSTALLATION. <br />4. 5. 5. <br />ALL FASTENERS AND TIE DOHN5 ARE TO PROVIDE THE UPLIFT CAPACITY GALLED <br />FOR IN THE PLANS ARE A MINIMUM. <br />4. 5. b. <br />ALL FASTENER TIE DOHN5, BEAM HANGERS, J015T HANGERS, AND FLOOR TRU55 <br />STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. <br />4. 5. 1. <br />CONCRETE EMBEDDED 'J' BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO <br />INITIAL SET OF THE CONCRETE, 5PAGING AND ALIGNMENT ARE TO BE IN ACCORDANCE <br />WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. <br />4. 5. 8. <br />CONCRETE EMBEDDED TIE DOWNS USED FOR TRU55 AND HALL UPLIFT ARE TO BE <br />PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLAGIN6 GROUT. <br />4. 5. cl. <br />P05T-IN5TALLED ANCHORS INTO CONCRETE <br />I. POST -INSTALLED ANCHORS SHALL ONLY BE USED HHERE SPECIFIED ON THE <br />GON5TRUGTION DOGUMENT5. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM PAN5GO <br />ENGINEERING, LLG PRIOR TO INSTALLING P05T-IN5TALLED ANCHORS IN PLACE OF <br />MISSING OR M15PLAGED GA5T-IN-PLAGE ANCHORS. <br />2. CARE SHALL BE TAKEN IN PLACING P05T-IN5TALLED ANCHORS TO AVOID CONFLICTS <br />WITH EXI5TING REBAR. <br />3, HOLES SHALL BE DRILLED AND GLEANED IN ACCORDANCE WITH THE MANUFACTURER'S <br />PRINTED INSTRUCTIONS (MPII). <br />4. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN TH05E SPECIFIED BELOH SHALL BE <br />SUBMITTED BY THE CONTRACTOR TO DE ALONG WITH CALCULATIONS THAT ARE <br />PREPARED 4 SEALED BY A REGISTERED PROFE55IONAL ENGINEER. THE GALGULATION5 <br />SHALL DEMONSTRATE THAT THE SUBSTITUTED PRODUCT 15 CAPABLE OF ACHIEVING <br />EQUIVALENT PERFORMANGE (MINIMUM) VALUES OF THE SPECIFIED PRODUCT U51NO THE <br />APPROPRIATE DE516N PROCEDURE AND/OR STANDARD(5) AS REQUIRED BY THE FLORIDA <br />BUILDING CODE. <br />5. PROVIDE PERIODIG SPECIAL INSPEGTION FOR THRESHOLD BUILDINGS FOR ALL ADHESIVE <br />AND MECHANICAL ANCHORS PER THE PRODUCT'S FLORIDA PRODUCT APPROVAL. <br />6. CONTACT MANUFACTURER'S REPRESENTATIVE FOR THE INITIAL TRAINING AND <br />INSTALLATION OF ANGHOR5 AND FOR PRODUCT RELATED QUESTIONS AND AVAILABILITY. <br />GALL 51MP50N STRONG -TIE AT (&00) qqq-50g11. GALL HILTI AT (8(b6) 445-8821. <br />1. MECHANICAL ANCHORS SHALL HAVE BEEN QUALIFIED FOR USE IN ACCORDANCE WITH AGI <br />355.2 AND IGG-E5 AGIg3 FOR CRACKED AND UNGRAGKED CONCRETE RECOGNITION. <br />PRE -APPROVED MECHANICAL ANCHORS INCLUDE: <br />A) 5CREH: 51MP5ON STRONG -TIE "TITEN-HD" OR HILTI "KHIK HU5-EZ" <br />B) EXPAN5ION: 51MP50N 5TRON6-TIE "STRONG -BOLT 2" OR HILTI "KHIK BOLT TZ" <br />8. ADHESIVE ANCHORS SHALL HAVE BEEN QUALIFIED FOR USE IN ACCORDANCE WITH AGI <br />555.4 AND IGG-E5 AC508 FOR CRACKED AND UNGRAGKED CONCRETE RECOGNITION. <br />ADHESIVE ANGHOR5 SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF 21 <br />DAYS PER AGI 318-14 02.2. HOLES SHALL BE DRY AT THE TIME OF INSTALLATION. <br />ADHESIVES SHALL HAVE MAX. IN-5ERVIGE SHORT-TERM TEMPERATURE OF 150°F, AND <br />MAX. IN-5ERVIGE LONG-TERM TEMPERATURE OF 110°F (AGI 318 DA.2.1). PRE -APPROVED <br />ADHESIVE ANCHORS INCLUDE: <br />A) EPDXY: 51MP50N 5TRONG-TIE "5ET-XP" OR HILTI "HIT -RE 500-5D" <br />B) FAST CURE: 51MP50N STRONG -TIE "AT-XP" OR HILTI "HIT-HY 200" <br />4.5. 10. <br />PO5T-IN5TALLED ANCHORS INTO MASONRY <br />I. MECHANICAL ANCHORS INSTALLED IN 50LID-GROUTED CONCRETE MASONRY SHALL HAVE <br />BEEN QUALIFIED FOR USE IN ACCORDANCE WITH IGG-E5 AGOI OR ACI06. <br />PRE -APPROVED MECHANICAL ANCHORS INCLUDE: <br />A) 5GREH: SIMP50N STRONG -TIE "TITEN-HD" OR HILTI "KHIK HU5-EZ" <br />B) EXPANSION: SIMPSON STRONG -TIE "STRONG -BOLT 2", "WEDGE -ALL" OR HILTI <br />"KHIK BOLT 3" <br />2. ADHESIVE ANCHORS INSTALLED IN 501-I0-67ROUTED CONCRETE MASONRY SHALL HAVE <br />BEEN QUALIFIED FOR USE IN ACCORDANCE WITH IGG-E5 AG58. PRE -APPROVED <br />ADHESIVE ANCHORS INGLUDE: <br />A) EPDXY: 51MP50N STRONG -TIE "SET-XP" <br />B) FAST CURE: SIMPSON STRONG -TIE "AT-XP" OR HILTI "HIT-HY 10" <br />3. ADHESIVE ANCHORS INSTALLED IN HOLLOW CONCRETE MASONRY 4 UNREINFORGED CLAY <br />BRICK MASONRY SHALL HAVE BEEN QUALIFIED FOR USE IN ACCORDANCE WITH IGG-E5 <br />AG58 OR AG60, RESPECTIVELY. PRE -APPROVED ADHESIVE ANCHORS INCLUDE: <br />A) SIMPSON 5TRONG-TIE "SET" OR HILTI "HIT-HY 10" <br />4. THE APPROPRIATE SCREEN TUBE SHALL BE USED FOR ALL ADHESIVE ANGHOR5 <br />INSTALLED IN HOLLOW CONCRETE MASONRY OR UNREINFORGED CLAY BRICK MA50NRY <br />AS REQUIRED BY THE ADHESIVE MANUFACTURER. <br />4. 6. MICRO -LAM LUMBER: <br />4. b. I. <br />MIGRO-LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: <br />E = 2000,000 P51 <br />Fb = 2,g50 PSI <br />Ft = 1050 P51 <br />Fc = 500 P51 (PERPENDICULAR) <br />Fc = 2300 (PARALLEL) <br />4.1. STEEL: <br />Fv = 285 P51 <br />4. 1. I. <br />INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED <br />STEEL ERECTOR. <br />4• �• 2• <br />FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE HITH A.I.5.G. <br />"5PEGIFIGATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL <br />STEEL FOR BUILDINGS". <br />4. 1. 3. <br />STRUCTURAL STEEL: A5TM A36/36M 08. <br />4.1. 4. <br />STEEL TUBING: A5TM A500-10, GRADE B. <br />4. 1. 5. <br />WELDED GONNECTION5: E10XX ELECTRODES, MINIMUM 51ZE FILLET HELPS 3/16", AH5 <br />CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. <br />4.7.6. <br />WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER <br />PLATES ON EACH 51DE OF THE HEB, OF A THICKNESS EQUAL TO BEAM FLANGE <br />THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. <br />4. 1. 1. <br />THE STEEL FRAME 15 "NON -SELF 5UPPORTING". ADEQUATE TEMPORARY SUPPORT <br />SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR <br />ELEMENTS ARE IN PLACE. <br />4. 8. SO L: <br />4. 8. I. THE FOOTING IS DESIGNED BASE ON 2000 P5F 501L BEARING PRESSURE. <br />GONTRACTOR/OHNER SHALL VERIFY 501L BEARING PRE55URE OF THE PROP05ED SITE. <br />4. 8. 2. ALL 501L 15 TO BE GLEAN d P015ONED FOR TERMITES PER FBG 6TH EDITION (201-7) <br />RESIDENTIAL SECTIONS R318.1, R318.2, R318.3, d R318.1 <br />TERMITE PROTECTION - <br />PLAN5 MUST SPEG I FY TYPE OF TERMITE TREATMENT <br />• 501L CHEMICAL BARRIER METHOD <br />• OTHER TREATMENT - MUST SPECIFY PROPOSED METHOD AND SUBMIT DOCUMENTATION, HHI <br />SUBSTANTIATES THE PROPOSED METHOD, 15 AN APPROVED TERMITE PROTECTION SYSTEM <br />OR METHOD. <br />IF GHEMIGAL SOIL TERMITE TREATMENT IS U5ED <br />I. <br />FBG 105.11- "A PERMANENT 51ON HHIGH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE-INSPEGTION AND TREATMENT CONTRACT RENEHAL SHALL BE <br />PROVIDED. THE 51ON SHALL BE P05TED NEAR THE HATER HEATER OR ELEGTRIG PANEL" <br />2. <br />CONDENSATE AND ROOF DOHN5POUT5 SHALL 015GHAROE AT LEAST 1'-0" AWAY FROM <br />THE BUILDING 51DE HALLS. <br />3. <br />IRRI6ATION/5PRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT <br />BE INSTALLED WITHIN P-O" OF THE BUILDING SIDE HALL. <br />4. <br />FBG R3153 - IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, <br />CLEARANCE BETHEEN EXTERIOR HALL COVERINGS AND FINAL EARTH GRADE ON <br />THE EXTERIOR OF A BUILDING HALL NOT BE LE55 THAN 6 INCHES (152 MM) <br />EXCEPTIONS: <br />I. PAINT OR DECORATIVE GEMENTITIOU5 FIN15H LE55 THAN I INCH (11.1 MM) THICK <br />ADHERED DIRECTLY TO THE MA50NRY FOUNDATION SIDEHALL. <br />2. ACCESS OR VEHICLE RAMPS HHIGH R15E TO THE INTERIOR FIN15H FLOOR <br />ELEVATION FOR THE WIDTH OF SUCH RAMPS ONLY. <br />3. A 4-INGH (102 MM) INSPECTION SPACE ABOVE PATIO AND GARAGE SLABS AND <br />ENTRY AREAS. <br />4. IF THE PATIO HAS BEEN I A F TERMITES, THE FIN15H ELEVATION <br />50 L TREATED OR TE TES, E 5 ELEVA 10 MAY <br />MATGH THE BUILDING INTERIOR FIN15H FLOOR ELEVATIONS ON MASONRY <br />CONSTRUCTION ONLY. <br />5. MA50NRY VENEERS GON5TRUGTED IN ACCORDANCE WITH 5EGTION R318.4. <br />5. <br />R316.1.1 IF 501L TREATMENT USED FOR SUBTERRANEAN TERMITE PREVENTION, THE INITIAL <br />CHEMICAL SOIL TREATMENT INSIDE THE FOUNDATION PERIMETER SHALL BE <br />DONE AFTER ALL EXCAVATION, BAGKFILLIN6 AND COMPACTION IS COMPLETE. <br />6. <br />R318.1.2 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, 501L <br />AREA DISTURBED AFTER INITIAL CHEMICAL SOIL TREATMENT SHALL BE RETREATED WITH <br />A CHEMICAL 501L TREATMENT INCLUDING SPACES BOXED OR FORMED. <br />1. <br />R318.1.3 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, SPACE IN <br />CONCRETE FLOORS BOXED OUT OR FORMED FOR THE SUBSEQUENT INSTALLATION OF <br />PLUMBING TRAPS, DRAINS OR ANY OTHER PURPOSE SHALL BE CREATED BY U51NG <br />PLASTIC OR METAL PERMANENTLY PLACED FORMS OF SUFFICIENT DEPTH TO ELIMINATE <br />ANY PLANNED 501L D15TURBANGE AFTER INITIAL CHEMICAL 501L TREATMENT. <br />8. <br />R318.1.4 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />CHEMICALLY TREATED 501L SHALL BE PROTECTED WITH A MINIMUM 6 MIL VAPOR <br />RETARDER TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE <br />VAPOR RETARDER PLACEMENT, RETREATMENT 15 REQUIRED. ANY WORK, INCLUDING <br />PLACEMENT OF REINFORCING STEEL, DONE AFTER CHEMICAL TREATMENT UNTIL THE <br />CONCRETE FLOOR 15 POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID <br />PENETRATING OR DISTURBING TREATED SOIL. <br />q. <br />R318.1.5 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />CONCRETE OVERPOUR OR MORTAR ACCUMULATED ALONG THE EXTERIOR FOUNDATION <br />PERIMETER SHALL BE REMOVED PRIOR TO EXTERIOR CHEMICAL 501L TREATMENT, TO <br />ENHANCE VERTICAL PENETRATION OF THE CHEMICALS. <br />10. <br />R318.1.6 IF 501L TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CHEMICAL <br />501L TREATMENTS SHALL AL50 BE APPLIED UNDER ALL EXTERIOR CONCRETE OF GRADE <br />WITH I FOOT (305 MM) OF THE PRIMARY STRUCTURE 51DEHALL5. ALSO, A VERTICAL <br />CHEMICAL BARRIER SHALL BE APPLIED PROMPTLY AFTER CONSTRUCTION 15 COMPLETED, <br />INCLUDING INITIAL LANDSCAPING AND IRRIOATION/5PRINKLER INSTALLATION. ANY 501L <br />DISTURBED AFTER THE CHEMICAL VERTICAL BARRIER 15 APPLIED SHALL BE PROMPTLY <br />RETREATED. <br />11. <br />R3I8.11 IF A REC715TERED TERMITIGIDE FORMULATED AND REGISTERED AS A BAIT SYSTEM <br />15 USED FOR SUBTERRANEAN TERMITE PREVENTION, SECTION R318.1.1, THROUGH SECTION <br />R318.1.6 DO NOT APPLY; HOWEVER, A SIGNED CONTRACT A55URING THE INSTALLATION, <br />MAINTENANCE AND MONITORING OF THE BAITING SYSTEM FOR A MINIMUM OF FIVE YEARS <br />FROM THE 155UE OF THE CERTIFICATE OF OCCUPANCY SHALL BE PROVIDED TO THE <br />BUILDING OFFICIAL PRIOR TO THE POURING OF THE SLAB, AND THE SYSTEM MUST BE <br />INSTALLED PRIOR TO FINAL BUILDING APPROVAL. <br />IF THE BAITING SYSTEM DIRECTIONS FOR U5 REQUIRE A MONITORING PHASE PRIOR TO <br />INSTALLATION OF THE PE5TIGIDE ACTIVE INGREDIENT, THE INSTALLATION OF THE <br />MONITORING PHASE COMPONENTS SHALL BE DEEMED TO CONSTITUTE INSTALLATION OF <br />THE SYSTEM. <br />12. <br />R318.1.8 IF A REGISTERED TERMITIGIDE FORMULATED AND REGISTERED AS A HOOD <br />TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, SECTIONS R318.1.1 <br />THROUGH R318.1.6 DO NOT APPLY. APPLICATION OF THE HOOD TREATMENT TERMITIGIDE5 <br />SHALL BE AS REQUIRED BY LABEL DIRECTIONS FOR USE, AND MUST BE COMPLETED <br />PRIOR TO FINAL BUILDING APPROVAL. <br />13. <br />R318.1 TERMITE PROTECTION. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED <br />TERMITIGIDE5, INCLUDING 501L APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES <br />APPLIED TO HOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED <br />FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. SEE SECTION 202, <br />REGISTERED TERMITIGIDE. UPON COMPLETION OF THE APPLICATION OF THE TERMITE <br />PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE 155UED TO THE <br />BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE <br />FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR <br />THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT 15 IN ACCORDANCE WITH <br />RULES AND LAH5 ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND <br />CONSUMER SERVICES." <br />14. <br />R316.2 PENETRATION. PROTECTIVE SLEEVES AROUND PIPING PENETRATING CONCRETE <br />SLAB -ON -GRADE FLOORS SHALL NOT BE OF GELLUL05E-GONTAINING MATERIALS. IF <br />501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL <br />HAVE A MAXIMUM HALL THICKNESS OF 0.010 INCH (0.25 MM), AND BE SEALED WITHIN THE <br />SLAB U51NG A NON -CORROSIVE CLAMPING DEVICE TO ELIMINATE THE ANNULAR SPACE <br />BETWEEN THE PIPE AND THE SLEEVE. NO TERMITIGIDE5 SHALL BE APPLIED IN51DE THE <br />SLEEVE. <br />15. <br />R318.3 GLEANING. CELLS AND CAVITIES IN MASONRY UNITS AND AIR GAP5 BETHEEN <br />BRICK, STONE OR MASONRY VENEERS AND THE STRUCTURE SHALL BE GLEANED OF ALL <br />NON -PRESERVATIVE TREATED OR NON -NATURALLY DURABLE HOOD, OR OTHER <br />GELLUL05E-CONTAININ6 MATERIAL PRIOR TO CONCRETE PLACEMENT. <br />EXCEPTION: INORGANIC MATERIAL MANUFACTURED FOR GLO5ING GELL5 IN FOUNDATION <br />CONCRETE MASONRY UNIT CONSTRUCTION OR GLEAN EARTH FILL PLACED IN CONCRETE <br />MASONRY UNIT VOIDS BELOW 5LA13 LEVEL BEFORE TERMITE TREATMENT 15 PERFORMED. <br />4. 8 .3. 501L <br />15 TO BE COMPACTED TO 015% MODIFIED PROCTOR A5 DEFINED BY A5TM D 1551-12el <br />NOTE: BORATE <br />APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. OR <br />SENTRIGON 5Y5TEM TO BE USED <br />1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR <br />BOR-A-GOR" PRODUCT OR 5ENTRICON SYSTEM, METHODS MUST BE DETERMINED AT PERMIT STAGE . <br />2) PRESSURE TREATED <br />LUMBER THAT HAS BEEN OUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF <br />HOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT IN5EGT INFESTATION. <br />REG2U I RED SAFETY GLAZING IN HAZARDOU5 LOCATI ON5 <br />SAFETY 64-AZIN6 (RE: FRG R30&.4) <br />R306.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS <br />FOR THE PURPOSES OF GLAZING: <br />I. GLAZING IN ALL FIXED AND OPERABLE PANELS OF 5HIN61N6, 5LIDIN6 AND BIFOLD DOORS. <br />EXCEPTIONS: <br />I. GLAZED OPENINGS OF A 51ZE THROUGH HHIGH A 3-INGH DIAMETER (76 mm) <br />SPHERE 15 UNABLE TO PASS. <br />2. DECORATIVE GLAZING. <br />2. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR SHALL BE GON51DERED TO <br />BE A HAZARDOUS LOCATION WHERE THE BOTTOM EXP05ED EDGE OF THE GLAZING 15 LE55 THAN 60 <br />INCHES (1524 MM) ABOVE THE FLOOR OR WALKING SURFACE AND IT MEETS EITHER OF THE FOLLOWIN6 <br />CONDITIONS: <br />I. WHERE THE 6LAZIN6 15 WITHIN 24 INCHES (610 MM) OF EITHER SIDE OF THE DOOR IN THE PLANE OF <br />THE DOOR IN A CLOSED POSITION. <br />2. WHERE THE GLAZING 15 ON A HALL PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED <br />POSITION AND WITHIN 24 INCHES (610 MM) OF THE HINGE 51DE OF AN IN-5HIN61N6 DOOR. <br />EXCEPTIONS: <br />I. DECORATIVE GLAZING. <br />2. HHERE THERE IS AN INTERVENING HALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE <br />GLAZING. <br />3. HHERE ACCESS THROUGH THE DOOR 15 TO A CLOSET OR STORAGE AREA 3 FEET N14 MM) OR LESS IN <br />DEPTH. GLAZING IN THIS APPLICATION SHALL COMPLY WITH SECTION R308.4.3. <br />4. GLAZING THAT 15 ADJACENT TO THE FIXED PANEL OF PATIO DOORS <br />3. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE WINDOW THAT MEETS ALL OF THE FOLLOHIN6 <br />CONDITIONS: <br />I. THE EXPOSED AREA OF AN INDIVIDUAL PANE 15 LARGER THAN q SQUARE FEET (0.836m=); AND <br />2. THE BOTTOM EDGE OF THE GLAZING 15 LESS THAN 16 INCHES (45-7 mm) ABOVE THE FLOOR; AND <br />3. THE TOP EDGE OF THE GLAZING 15 MORE THAN 36 INCHES M14 mm) ABOVE THE FLOOR; AND <br />4. ONE OR MORE HALKIN6 SURFACE ARE WITHIN 36 INCHES N14 mm), MEASURED HORIZONTALLY AND IN A <br />STRAIGHT LINE, OF THE GLAZING. <br />EXCEPTIONS: <br />I. DECORATIVE GLAZING. <br />2. HHEN A HORIZONTAL RAIL 15 INSTALLED ON THE ACCESSIBLE 51DE(5) OF <br />THE GLAZING 34 TO 38 INCHES (846 TO q65) ABOVE THE HALKIN6 <br />SURFACE. THE RAIL SHALL BE CAPABLE OF HITH5TANDING A HORIZONTAL <br />LOAD OF 50 POUNDS PER LINEAR FOOT (750 Wm) WITHOUT CONTACTING <br />THE 6LA55 AND BE A MINIMUM OF 1 1/2" INCHES (38 mm) IN GROSS SECTIONAL HEIGHT. <br />3. OUTBOARD PANES IN INSULATING GLA55 UNITS AND OTHER MULTIPLE GLAZED PANELS HHEN THE <br />BOTTOM EDGE OF THE GLASS 15 25 FEET (7620 mm) OR MORE ABOVE GRADE, A ROOF, HALKIN6 <br />SURFACES OR OTHER HORIZONTAL (WITHIN 45 DEGREES (O.cM RAP) OR HORIZONTAL) SURFACE <br />ADJACENT TO THE GLA55 EXTERIOR. <br />4. ALL GLAZING IN RAILIN66 REGARDLESS OF AREA OR HEIGHT ABOVE A HALKIN6 SURFACE. INCLUDED ARE <br />STRUCTURAL BALUSTER PANELS AND NON5TRUGTURAL INFILL PANELS. <br />5. GLAZING IN HALL5, ENCLOSURES OR FENCES GONTAINING OR FACING HOT TUBS, 5PA5, HHIRLPOOL5, <br />SAUNAS, STEAM ROOMS, BATHTUBS, 5HOWER5 AND INDOOR OR OUTDOOR 5HIMMIN6 POOLS WHERE THE <br />BOTTOM EXP05ED EDGE OF THE GLAZING 15 LE55 THAN 60 INCHES (1524 MM) MEASURED VERTICALLY <br />ABOVE ANY STANDING OR WALKING SURFACE SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. <br />THIS SHALL APPLY TO 51NOLE 6LAZIN6 AND EACH PANE IN MULTIPLE GLAZING. <br />EXCEPTION: GLAZING THAT 15 MORE THAN 60 INCHES (1524 MM), MEASURED HORIZONTALLY AND IN A <br />STRAIGHT LINE, FROM THE HATER'S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL OR 5HIMMIN6 POOL OR <br />FROM THE EDGE OF A 5HOHER, SAUNA OR STEAM ROOM. <br />b. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN 36 INCHES (4114 MM) ABOVE <br />THE PLANE OF THE ADJACENT WALKING SURFACE OF 5TAIRHAY5, LANDINGS BETHEEN FLI6HT5 OF STAIRS <br />AND RAMP5 SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. <br />EXCEPTIONS: <br />I. WHERE A RAIL 15 INSTALLED ON THE ACCESSIBLE 51DE(5) OF THE GLAZING 34 TO 38 INCHES 064 TO <br />0165 MM) ABOVE THE WALKING SURFACE. THE RAIL SHALL BE CAPABLE OF HITH5TANDING A <br />HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT ('130 N/M) WITHOUT CONTACTING THE GLA55 AND <br />HAVE A CRO55-5ECTIONAL HEIGHT OF NOT LE55 THAN 1 1/2 INCHES (38 MM), <br />2. GLAZING 36 INCHES (c114 MM) OR MORE MEASURED HORIZONTALLY FROM THE HALKIN6 SURFACE. <br />1. GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING 15 LE55 THAN <br />36 INCHES (0114 MM) ABOVE THE LANDING AND WITHIN A 60-INGH (1524 MM) HORIZONTAL ARG LESS THAN <br />I80 DEGREES FROM THE BOTTOM TREAD NOSING SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. <br />EXCEPTION: THE 6LAZIN6 15 PROTECTED BY A GUARD COMPLYING WITH SECTION R312 AND THE PLANE OF <br />THE GLASS IS MORE THAN 0 INCHES (45-7 MM) FROM THE GUARD. <br />NOTE: <br />IT 15 THE GONTRAGTOR5 RE5PON5113ILITY TO REVIEW ALL DRAWINGS BEFORE CON5TRUGTION BEGI145. <br />DAN5GO ENGINEERING, LLG 15 RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THI5 PROJECT ONLY. ANY <br />D15GREPANGY BETWEEN FIELD CONDITIONS, OTHER DE51ON PROFE5510NAL5' SHOP DRAHING5, <br />GONTRACTORS' BUILDING METHODS, AND THE5E SIGNED AND SEALED DRAHIN65 MU5T BE BROUGHT TO THE <br />ATTENTION OF FLORIDA DE51ON SOLUTIONS, ING. PRIOR TO THE GOMMENGEMENT OF GON5TRUCTION. <br />ATTENTION: GHEMIGAL GHANGE5 IN PRE55URE TREATED HOOD5 <br />A5 OF DEGEMBER 315T, 2003, GHROMATED COPPER ARSENATE (GGA-G) HILL NO LONGER BE PRODUGED FOR <br />RE5IDENTIAL OR GENERAL 6ON5UMER USE. SEVERAL NEW PRESSURE TREATED HOOD ALTERNATIVES HAVE <br />BEEN CREATED TO REPLAGE GGA-G. MANY OF THE NEW PRE55UFZE TREATED WOODS U5E GHEMIGALS THAT <br />ARE GORRO51VE TO STEEL. IT 15 THE CONTRAGTOR'S RE5PON5115ILITY TO VERIFY THE TYPE OF HOOD <br />TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RE515T CORROSION. FOR EXAMPLE, AGO-G, <br />AGO-D, GBA-A, OR GA-15 REQUIRE HOT -DIPPED GALVANIZED OR 5TAINLE55 STEEL FASTENERS. DOT 50DIUM <br />BORATE (515X) DOE5 NOT. <br />HORST GA5E DE51ON PRE55URE TABU <br />BUILDING DATA <br />WIND SPEED 140 MPH (Vasd 108 MPH) <br />WIND EXPOSURE -- 'C' (FRC R301) <br />INTERNAL PRESSURE COEFFICIENT= +/- 0.18 ENCLOSED BLDG) <br />DESIGN WIND PRESSURE: <br />(COMPONENT AND CLADDING:) WORST CASE (10 SF - END ZONE) <br />0 END ZONE 15 ONLY WITHIN 5'-0' <br />OF ALL EXTERIOR BUILDING CORNERS <br />WINDOWS AND DOORS (ASD PRESSURES) <br />140 MPH + 25b PSF / - 343 PSF (END) UNLESS NOTED ON FLOOR PLANS <br />+ 25b F15F / - 21.1 PSF (INTERIOR) UNLE55 NOTED ON FLOOR PLANS <br />GARAGE DOORS (ASD PRESSURES) <br />SINGLE 9x1 + 223 PSF / - 253 PSF <br />DOUBLE 16x1 + 21A F15F / - 23.8 PSF <br />-711 <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p.813.645.0166 <br />f. 813.645.9698 <br />www.danscoengineedng.com <br />CA 25948 <br />O <br />N <br />Z uj <br />O <br />arnL^ <br />ate^ <br />pQ� LIP <br />} u- rNn <br />z Z tn- <br />H <br />w ZLu <br />O <br />U <br />CL <br />L1J Lu <br />W <br />Lu a cn <br />= o C/) <br />1 m <br />N W <br />Z <br />Q O mm <br />U O <br />Z Lu U <br />Z <br />� Z 00 <br />V) O � <br />CL <br />V) <br />TO THE BEST OF THE ENGINEERS <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd = 108MPH), 3 SEC. GUST. <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT = i0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VAUD FOR 12 MONTHS <br />AFTER THE DATE R IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OF THIS DRAWING ONLY. <br />OW19 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />02019 - THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CUENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHRIITED. <br />REVISION: <br />DATE DESCRIPTION <br />UPDATED CONNECTION <br />06.08.18 1.01 CROSS-REFERENCE TABLE <br />AND STAIR STRAP <br />01.09.19 1.02 ROOF UNDERLAYMENT REV. <br />02 11 19 1 03 UPDATED CONNECTION <br />CROSS-REFERENCE TABLE <br />VERSIW_ ' &f.02.11.19 <br />ha ,'lam C\I s- <br />... CV I1_ y <br />s, G� <br />IBC <br />r>, xgrac;c+A�r� <br />c� <br />cv <br />cn <br />CD <br />fL <br />2 <br />O <br />w <br />co <br />co J <br />z <br />Q LL = 0 <br />W U` r 3 <br />N Qv �cci �N <br />W L00 <br />%- W <br />Z Q w = LJj 1`14 LLi <br />5 <br />W ❑ ❑ <br />SHEET TITLE: <br />STRUCTURAL NOTES <br />SHEET INFORMATION: <br />JOB NO.: 390441 <br />DATE ISSUED: 04.04.19 <br />DRAWN BY: LF <br />REVIEWED BY: TH <br />SIN <br />LO <br />O <br />co <br />O <br />1 <br />N <br />co <br />11q' <br />CN <br />LO <br />r- <br />