OPTIONAL OVERHEAD SERVICE SAME A6 — <br />UNDERGROUND 150 OR 200 AMP SERVICE <br />METER <br />REFER TO FLOOR PLAN FOR <br />NOTED AMPS, REQUIRED <br />UNDERGROUND SERVICE <br />BY POWER COMPANY <br />04 GROUNDING WIRE WITH CODE <br />APPROVED CLAMP PER 250.50 <br />AND 250.52 OF THE 2014 NEC. <br />150 = #i COPPER OR 2/0 ALUMINUM <br />200 m 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT, <br />TYPICAL A/C <br />MAIN D15C.1 ELECTRICAL D15CONNECT <br />150 OR PANEL <br />200 AMP #12 COPPER TO APPLIANCES AND GFI <br />#14 COPPER TO LIGHT5 AND OUTLETS <br />#10 COPPER TO WATER HEATER <br />#8 COPPER TO RANGE <br />16 COPPER TO HVAC <br />1-1 <br />INTERSYSTEM BONDING TERMINATION PER NEC 08, 25034 <br />ELECTRICAL RISER DIAGRAM <br />NOTE: <br />ELECTRICAL MATERIAL5 AND IN5TALLATION5 SHALL COMPLY W/ APPLICABLE PROV1510N5 <br />OF THE NFPA 10-08, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY <br />STAIR NOT 5 <br />RAILING <br />BALU5TER5 SHALL BE 5PAGED 50 THAT A 4" SPHERE CANNOT PA55 THROUGH. <br />HANDRAIL5 <br />HANDRAIL5 FOR 5TAIRWAY5 SHALL BE CCNTINUOU5 FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP R15ER OF <br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWE5T R15ER. HANDRAIL ENDS SHALL BE RETURNED OR 5HALL TERMINATE IN NEWEL P05T5 OR <br />5AFETY TERMINAL5. HANDRAIL5 ADJACENT TO A WALL 5HALL HAVE A 5PAGE OF NOT LE55 THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAIL5. <br />CONTINUOUS GRA5PABLE HANDRAIL MU5T MEET TYPE ONE OR TYPE TWO CRITERIA <br />UNDER -STAIR PROTECTION <br />ENCL05ED ACCE551BLE 5PAGE UNDER 5TAIR5 5HALL HAVE WALL5, UNDER -STAIR 5URFACE AND ANY SOFFIT PROTECTED ON THE <br />ENCL05ED SIDE W/ 1/2 INCH GYPSUM BOARD PER F.B.C. RESIDENTIAL 6th EDITION (2011) - R302.1 AND R302,11 <br />5TAIRWALL FRAME NOTE <br />ALL 5TAIRWELL 5URROUNDING WALL5 AND KNEE WALLS ARE TO BE FRAMED AT 16" O.C. TO PROTECT FROM FALLING HAZARD <br />OCCUPANCY AND CONSTRUCTION TiPE: <br />TH15 UNIT HA5 AN R3 OCCUPANCY AND BUILDING TYPE V-B CLA55IFICATION. <br />CEILING CONSTRUCTION: <br />I. THE GARAGE 5HALL BE SEPARATED FROM THE RE5IDENCE AND IT5 ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED <br />TO THE GARAGE 51DE. GARAGE5 BENEATH HABITABLE ROOM5 5HALL BE 5EPARATED FROM ALL HABITABLE ROOM5 ABOVE BY NOT LE55 THAN <br />5/E INCH (15.9 mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT, WHERE THE 5EPARATION 15 A FLOOR=CEILING A55EMBLY, THE STRUCTURE <br />SUPPORTING THE 5EPARATION 5HALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT. <br />DUELLING / GARAGE OPENINGS: <br />1. THE OPENING BETWEEN THE GARAGE AND LIVING AREA 5HALL BE EQUIPPED WITH SOLID WOOD DOOR5 NOT LE55 THAN 1 3/8" IN THICKNE55, <br />5OLID CORE lS.GJ OR HONEYCOMB CORE STEEL DOORS NOT LE55 THAN 1 3/6" THICK, OR 20 MINUTE FIRE RATED DOOR5, <br />2, ALL DOORS FROM GARAGE ADJACENT TO LIVING 5PAGE MUST BE EITHER A 50LID GORE DOOR OR HAVE A MIN, FIRE RATING OF 20 MINUTE5. <br />E RE55: <br />EACH BEDROOM MU5T HAVE ONE WINDOW THAT COMPLIE5 WITH EGRE55 CODES, IF THERE 15 NO ACCE55 TO EXTERIOR THROUGH A DOOR. THE <br />WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM. <br />WINDOW INSTALLATION: <br />WINDOW5 5HALL BE INSTALLED AND FLA5HED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION IN5TRUCTION5, WRITTEN <br />INSTALLATION IN5TRUCTION5 5HALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. <br />TERMITE PROTECTION: <br />I. PENETRATION, PROTECTIVE 5LEEVE5 AROUND PIPING PENETRATING CONCRETE 5LA5=ON-GRADE FLOOR5 SHALL NOT BE OF GELLUL05E <br />CONTAINING MATERIAL5. IF 501L TREATMENT 15 U5ED FOR 5UBTERRANEAN TERMITE PROTECTION, THE SLEEVE 5HALL HAVE A MAXIMUM WALL <br />THICKNE55 OF 0.010 INCH, AND BE SEALED WITHIN THE 5LAB U51NG A NON-CORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR 5PAGE <br />BETWEEN THE PIPE AND THE SLEEVE. NO TERMITIGIDE5 5HALL BE APPLIED IN51DE THE SLEEVE. <br />2. PROTECTION AGAINST DECAY AND TERMITE5. - CONDENSATE LINES, IRRIGATION / 5PRINKLER 5Y5TEM R15ER5 FOR 5PRAY HEADS, AND ROOF <br />DOWN5POUT5 5HALL D15CHARGE AT LEAST I FOOT (305 mm) AWAY FROM THE 5TRUCTURE 511DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL <br />EXTEN51ON5, OR 5PLA5H BLOCKS. GUTTER5 WITH DOWN5POUT5 ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LE55 THAN 6 INCHE5 (152 mm) <br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKE5 OR ON A ROOF ABOVE ANOTHER ROOF. <br />TOP RAILING <br />NOTE: 5UBFLOOR ADHESIVE 15 U5ED IN ADDITION <br />BALU5TER5 <br />TO NAILS ON WOOD COMPONENT5. <br />MAX 5PACING 4" <br />1 X 8 PAINTED WE). CAP <br />STRINGER 15 LAMINATED TO A THICKNE55 EQUIVALENT TO <br />OGEE 5TOP <br />THE 51ZE OF A 2 X 12 5.Y.P. AND 15 NAILED TO EACH <br />TREAD W/ 16d NAILS FROM THIRD LAMINATE TO TREAD— <br />OPT, 2 X 2 BLOCKING NAILED <br />TO TREAD AND R15ER. <br />3-2 X 12 STRINGER <br />2 X BLOCKING NAILED TO STRINGER, + <br />3/4" RISERS <br />R15ER, AND TREAD. + + + <br />2 X TREADS± RIP FROM 2x12 <br />I X 5PRUCE 03 OR 3/4" CDX. + + <br />TO 51ZE NOTED ON PLAN <br />PLYWD. R15ER. + <br />2 X 5OUTHERN YELLOW PINE # <br />(ACTUAL THICKNE55 15 1 1/2") TREAD. <br />TYP. OPT. RAILING ELEVATION CLOSED RISER DETAIL <br />SCALE: I/2" = I' 0" 50ALE: 1/2" ; I'-0" <br />"'�WEL P05T <br />)P RAILING <br />�LU5TER 4" O.C. <br />10E RAIL (REMOVE <br />METAL 5PINDLE5) <br />8 PAINTED WE). CAP <br />aEE STOP <br />11 a-mam 1 OoR LINE <br />4- <br />OPTIONAL <br />v: <br />TREAD <br />om <br />2X4WALL <br />1/2" GYP BD, <br />3/4" 5KIRT BD. <br />2 X 4 SPACER <br />2X12 <br />STRINGER <br />TYPICAL STAIR <br />FRAMING DETAIL <br />B 5CALE: 3/4" = 1411 <br />GENERAL CONSTRUCTION NOTES <br />CHAPTERS AND SECTIONS REFER TO F.B.C. RESIDENTIAL 6th EDITION (2011) <br />MECHANICAL AND HVAC <br />I. ENERGY GALCULATION5 FOR HEATING AND COOLING CAPACITIES 5HALL BE FURNI5HED BY THE GENERAL CONTRACTOR A5 AN ATTACHMENT TO <br />TH15 PLAN 5ET AT THE TIME OF APPLICATION FOR PERMIT. <br />2, MECHANICAL APPLIANCE5 5HALL BE ACCE5515LE FOR INSPECTION, 5ERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT <br />CON5TRUCTION, OTHER APPLIANCE5, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING IN5PECTED, SERVICED, <br />REPAIRED, OR REPLACED, A LEVEL WORKING 5PAGE AT LEAST 30 INCHE5 (162 mm) DEEP AND 30 INCHE5 (162 mm) WIDE 5HALL BE PROVIDED IN <br />FRONT OF THE CONTROL 51DE TO 5ERVICE AN APPLIANCE. <br />3. DUCT5 IN THE GARAGE AND DUCT5 PENETRATING THE WALL5 OR CEILING5 5EPARATING THE DWELLING FROM THE GARAGE 5HALL BE <br />CONSTRUCTED OF A MIN. % GAUGE (0.48 mm) 5HEET STEEL OR OTHER APPROVED MATERIAL AND 5HALL HAVE NO OPENINGS INTO THE GARAGE. <br />4, FOUNDATION5 AND 5UPPORT5 FOR OUTDOOR MECHANICAL 5Y5TEM5 5HALL BE RA15ED AT LEAST 3 INCHE5 (16 mm) ABOVE THE FINI5HED <br />GRADE AND 5HALL AL50 CONFORM TO THE MANUFACTURER'5 INSTALLATION IN5TRUCTION5. <br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDEN51NG APPLIANCE5 5HALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO <br />ANY BUILDING COMPONENT WILL OCCUR A5 A RESULT OF 5TOPPAGE IN THE CONDENSATE DRAIN PIPING 5Y5TEM, THESE PANS 5HALL BE <br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVI51ON5 OF 5ECTION5 M1411.3. <br />EXHAUST FANS AND VENTING <br />(.OUTDOOR D15CHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST 5Y5TEM 5HALL BE D15CHARGED TO THE OUTDOOR5. AIR SHALL <br />NOT BE EXHAUSTED INTO AN ATTIC, 5OFFIT, RIDGE VENT OR CRAWL 5PAGE. <br />2, EXHAU5T AIR FROM BATH ROOM5 AND TOILET ROOMS 5HALL NOT BE RECIRCULATED WITHIN A RE5IDENCE OR TO ANOTHER DWELLING UNIT AND <br />5HALL BE EXHAUSTED DIRECTLY TO THE OUTDOOR5. EXHAU5T AIR FROM BATHROOM5 AND TOILET ROOMS 5HALL NOT D15CPARGE INTO AN ATTIC, <br />CRAWL 5PAGE, OR OTHER AREA5 IN51DE THE BUILDING. <br />3, DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAU5T DUCT 5HALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE <br />WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT 5HALL BE REDUCED 2.5 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND <br />AND 5 FEET (1524 mm) POP, EACH 90 DEGREE (1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAU5T DUCT DOES NOT INCLUDE THE TRANSITION <br />DUCT. <br />EXCEPTION - WHERE A GLOTHE5 DRYER B005TER FAN 15 INSTALLED AND L15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF <br />THE EXHAU5T DUCT, INCLUDING ANY TRAN51TION DUCT, 5HALL BE PERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FAN MANUFACTURER'S <br />INSTALLATION IN5TRUCTION5. WHERE A CLOTHE5 DRYER B005TER PAN 15 INSTALLED AND NOT READILY ACCE551BLE FROM THE ROOM IN WHICH <br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL 5HALL BE PLACED ADJACENT TO WHERE THE EXHAU5T DUCT ENTERS THE WALL. THE <br />LABEL 5HALL BEAR THE WORD5 "TH15 DRYER EXHAU5T 5Y5TEM 15 EQUIPPED WITH A REMOTELY LOCATED 5005TER FAN." <br />4, PROVIDE LOUVER DEVICE5 AT INTAKE AND EXHAU5T LOGATION5 IN ACCORDANCE WITH <br />AMCA 5TANDARD 550 IN FBC. <br />ROUGH -IN IN5RECTION REOUE5T NOTE <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH=IN5 MUST BE <br />COMPLETE, IN5PEGTED AND APPROVED BEFORE REQUE5TING THE <br />FRAMING INSPECTION. <br />WINDOW FALL PROTECTION <br />IN DWELLING UNIT5, WHERE THE OPENING OF AN OPERABLE WINDOW 15 <br />LOCATED MORE THAN 12 INCHE5 ABOVE THE FINI5HED GRADE OR <br />SURFACE BELOW, THE LOWE5T PART OF THE CLEAR OPENING OF THE <br />WINDOW SHALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINISHED <br />FLOOR OF THE ROOM IN WHICH THE WINDOW 13 LOCATED. OPERABLE <br />5ECTION5 OF WINDOWS SHALL NOT PERMIT OPENING5 THAT ALLOW <br />PA55AGE OF A 4 INCH DIAMETER SPHERE WHERE 5UGH OPENING5 <br />ARE LOCATED WITHIN 24 INCHE5 OF THE FINISHED FLOOR PER F.B.C. <br />RESIDENTIAL 6th EDITION (2011) - SECTION R312.2. <br />WINDOW FALL PREVENTION DEVICES AND WINDOW GUARD5, WHERE <br />PROVIDED, SHALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090 <br />PER F.B.G. RESIDENTIAL 6th EDITION (2011) - 5ECTION R312.2, <br />INSULATION NOTES <br />• GMU WALL5:--==- R=FOIL 4.1 KNEE WALL5 THAT <br />BACK UP TO CEILING <br />• FRAME WALLS: ---- =--= R-13 AREA ONLY: ==== --- =__= R-19 <br />• CEILING:------------- R-30 <br />ON51TE FOUNDATION 5URVEi NOTE <br />A FOUNDATION SURVEY 5HALL BE PERFORMED AND A COPY OF THE <br />SURVEY 5HALL BE ON THE 51TE FOR THE BUILDING IN5PECTOR'5 U5E, <br />OR ALL PROPERTY MARKERS 5HALL BE EX1305ED AND A STRING <br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED <br />5ETBACK5, <br />CLING AT ENTRY' NOTE <br />ALL ENTRY GLG5. TO BE 15/32 058, CEMENTITOU5 FIN15P (U.N.0) <br />GA5 APPLIANCE PROTECTION IN 6ARA6E NOTE <br />PROTECTION OF 6A5 APPLIANCES IN RESIDENTIAL GARAGES: <br />MINIMUM 3" DIAMETER 5CH 40 5TEEL PIPE, 2 FT. BELOW CONCRETE <br />SLAB AND 3 FT. ABOVE FIN15PED FLOOR, <br />GENERAL NOTES <br />• DUE TO VARIATIONS IN CITY REQUIREMENT5, 5UBDIV1510N <br />5PECIFICATION5, CON5TRUCTION TECHNiQUE5, DIVER5ITY IN <br />MATERIAL5, AND PLAN REV1510N5, ALL DIMEN5ION5 AND <br />ELEVATIONS MAY VARY PER INDIVIDUAL PLAN, ACTUAL FIELD <br />CONDITION5 MAY VARY AND MUST BE VERIFIED BEFORE <br />PROCEEDING WITH CON5TRUCTION. <br />• ELECTRICAL LOCATION5 5HOWN ON DRAWING5 MAY BE CHANGED <br />AT THE 50LE D15CRETION OF CALATLANTIC HOMES OR IT5 <br />LICEN5ED ELECTRICIAN IN ORDER TO COMPLY W/ NATIONAL AND <br />MUNICIPAL BUILDING AND ELECTRICAL CODES. CALATLANTIC <br />HOME5 WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLET5 <br />AND / OR 5WITCHE5 5HOWN. <br />• ALL PLUMBING DIMEN51ON5 ARE APPROXIMATE FROM THE CENTER <br />LINE OF THE FIXTURE TO THE EXTERIOR SLAB EDGE. IT 15 THE <br />RE5PON515ILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF <br />ALL PLUMBING DIMEN51ON5. <br />NOTE: ANY DIMEN51ON5 AND/OR CALLOUT5 WITHIN TH15 5ET OF DRAWING5 REFERENCING <br />LUMBER 51ZE5 OR WALL THICKNE55E5 ARE TO BE CON5IDERED "NOMINAL DIMEN51ON5" <br />CHIMNEY HINT R OUIREMENT5: <br />WHEN STANDARD OR OPTIONAL FIREPLACE 15 TO BE INSTALLED THE CHIMNEY MU5T EXTEND 3'-0" PAST THE HIGHER POINT WHERE IT <br />EXTENDS THROUGH THE ROOF AND MUST BE 2'=0" HIGHER THAN THE ROOF OR RIDGE THAT 15 10'-0" AWAY OR CL05ER. <br />TUE AND 5HOWER ARE45: <br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH A5TM Cl286, CI325, OR CIIIE <br />AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION5 5HALL BE U5ED A5 BACKER5 FOR WALL TILE IN TUB AND <br />SHOWER AREAS, AND WALL PANEL5 IN 5HOWER AREA5. <br />FLOOD ZONE REOUIREMENT5: <br />PLAN MEET5 OR EXCEEDS FEMA FLOOD FINI5HED GARAGE FLOOR ELEVATION. <br />BEWS <br />DESIGN GROVP <br />150 STATE STREET' FAST <br />OLDSMAR, FLORIDA 34677 <br />813.925. 130d TEL <br />813 . 925.1800 FAX <br />W W W.DAVLSBEWS.COM <br />TAMPA • DEiWER. <br />� EST. 1994 <br />s <br />0 <br />zC) <br />N <br />0 <br />1-4 <br />�� <br />�V)Mo <br />mac% M� <br />a �Ln <br />Q a� <br />M <br />Q U Q� <br />.� <br />ZC)H <br />wwo <br />J � <br />d- <br />J <br />Oz <br />�o <br />W <br />za <br />z� <br /><a <br />WQ�ft <br />oQgo <br />J <br />o W cy <br />u J <br />aC2u-o <br />O W � N <br />W �Wo <br />o(n <br />Q zz <br />}O <br />�z <br />W <br />Z �� <br />0 Q J <br />Q <br />QC z <br />W <br />T-+ Lu <br />z Q ow <br />z `-' <br />z U Z z0 <br />J O <br />ui z j CD <br />z Q L <br />m z w = <br />O 0- w � m <br />SCALE : AS NOTED <br />DATE : 10-19-2018 <br />VERSION NO. <br />imo <br />SHEET NO. <br />DT1 <br />DAVIS <br />I� 1 <br />