OPTIONAL OVERHEAD SERVICE SAME A6 —
<br />UNDERGROUND 150 OR 200 AMP SERVICE
<br />METER
<br />REFER TO FLOOR PLAN FOR
<br />NOTED AMPS, REQUIRED
<br />UNDERGROUND SERVICE
<br />BY POWER COMPANY
<br />04 GROUNDING WIRE WITH CODE
<br />APPROVED CLAMP PER 250.50
<br />AND 250.52 OF THE 2014 NEC.
<br />150 = #i COPPER OR 2/0 ALUMINUM
<br />200 m 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT,
<br />TYPICAL A/C
<br />MAIN D15C.1 ELECTRICAL D15CONNECT
<br />150 OR PANEL
<br />200 AMP #12 COPPER TO APPLIANCES AND GFI
<br />#14 COPPER TO LIGHT5 AND OUTLETS
<br />#10 COPPER TO WATER HEATER
<br />#8 COPPER TO RANGE
<br />16 COPPER TO HVAC
<br />1-1
<br />INTERSYSTEM BONDING TERMINATION PER NEC 08, 25034
<br />ELECTRICAL RISER DIAGRAM
<br />NOTE:
<br />ELECTRICAL MATERIAL5 AND IN5TALLATION5 SHALL COMPLY W/ APPLICABLE PROV1510N5
<br />OF THE NFPA 10-08, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY
<br />STAIR NOT 5
<br />RAILING
<br />BALU5TER5 SHALL BE 5PAGED 50 THAT A 4" SPHERE CANNOT PA55 THROUGH.
<br />HANDRAIL5
<br />HANDRAIL5 FOR 5TAIRWAY5 SHALL BE CCNTINUOU5 FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP R15ER OF
<br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWE5T R15ER. HANDRAIL ENDS SHALL BE RETURNED OR 5HALL TERMINATE IN NEWEL P05T5 OR
<br />5AFETY TERMINAL5. HANDRAIL5 ADJACENT TO A WALL 5HALL HAVE A 5PAGE OF NOT LE55 THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAIL5.
<br />CONTINUOUS GRA5PABLE HANDRAIL MU5T MEET TYPE ONE OR TYPE TWO CRITERIA
<br />UNDER -STAIR PROTECTION
<br />ENCL05ED ACCE551BLE 5PAGE UNDER 5TAIR5 5HALL HAVE WALL5, UNDER -STAIR 5URFACE AND ANY SOFFIT PROTECTED ON THE
<br />ENCL05ED SIDE W/ 1/2 INCH GYPSUM BOARD PER F.B.C. RESIDENTIAL 6th EDITION (2011) - R302.1 AND R302,11
<br />5TAIRWALL FRAME NOTE
<br />ALL 5TAIRWELL 5URROUNDING WALL5 AND KNEE WALLS ARE TO BE FRAMED AT 16" O.C. TO PROTECT FROM FALLING HAZARD
<br />OCCUPANCY AND CONSTRUCTION TiPE:
<br />TH15 UNIT HA5 AN R3 OCCUPANCY AND BUILDING TYPE V-B CLA55IFICATION.
<br />CEILING CONSTRUCTION:
<br />I. THE GARAGE 5HALL BE SEPARATED FROM THE RE5IDENCE AND IT5 ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED
<br />TO THE GARAGE 51DE. GARAGE5 BENEATH HABITABLE ROOM5 5HALL BE 5EPARATED FROM ALL HABITABLE ROOM5 ABOVE BY NOT LE55 THAN
<br />5/E INCH (15.9 mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT, WHERE THE 5EPARATION 15 A FLOOR=CEILING A55EMBLY, THE STRUCTURE
<br />SUPPORTING THE 5EPARATION 5HALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT.
<br />DUELLING / GARAGE OPENINGS:
<br />1. THE OPENING BETWEEN THE GARAGE AND LIVING AREA 5HALL BE EQUIPPED WITH SOLID WOOD DOOR5 NOT LE55 THAN 1 3/8" IN THICKNE55,
<br />5OLID CORE lS.GJ OR HONEYCOMB CORE STEEL DOORS NOT LE55 THAN 1 3/6" THICK, OR 20 MINUTE FIRE RATED DOOR5,
<br />2, ALL DOORS FROM GARAGE ADJACENT TO LIVING 5PAGE MUST BE EITHER A 50LID GORE DOOR OR HAVE A MIN, FIRE RATING OF 20 MINUTE5.
<br />E RE55:
<br />EACH BEDROOM MU5T HAVE ONE WINDOW THAT COMPLIE5 WITH EGRE55 CODES, IF THERE 15 NO ACCE55 TO EXTERIOR THROUGH A DOOR. THE
<br />WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM.
<br />WINDOW INSTALLATION:
<br />WINDOW5 5HALL BE INSTALLED AND FLA5HED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION IN5TRUCTION5, WRITTEN
<br />INSTALLATION IN5TRUCTION5 5HALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW.
<br />TERMITE PROTECTION:
<br />I. PENETRATION, PROTECTIVE 5LEEVE5 AROUND PIPING PENETRATING CONCRETE 5LA5=ON-GRADE FLOOR5 SHALL NOT BE OF GELLUL05E
<br />CONTAINING MATERIAL5. IF 501L TREATMENT 15 U5ED FOR 5UBTERRANEAN TERMITE PROTECTION, THE SLEEVE 5HALL HAVE A MAXIMUM WALL
<br />THICKNE55 OF 0.010 INCH, AND BE SEALED WITHIN THE 5LAB U51NG A NON-CORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR 5PAGE
<br />BETWEEN THE PIPE AND THE SLEEVE. NO TERMITIGIDE5 5HALL BE APPLIED IN51DE THE SLEEVE.
<br />2. PROTECTION AGAINST DECAY AND TERMITE5. - CONDENSATE LINES, IRRIGATION / 5PRINKLER 5Y5TEM R15ER5 FOR 5PRAY HEADS, AND ROOF
<br />DOWN5POUT5 5HALL D15CHARGE AT LEAST I FOOT (305 mm) AWAY FROM THE 5TRUCTURE 511DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL
<br />EXTEN51ON5, OR 5PLA5H BLOCKS. GUTTER5 WITH DOWN5POUT5 ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LE55 THAN 6 INCHE5 (152 mm)
<br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKE5 OR ON A ROOF ABOVE ANOTHER ROOF.
<br />TOP RAILING
<br />NOTE: 5UBFLOOR ADHESIVE 15 U5ED IN ADDITION
<br />BALU5TER5
<br />TO NAILS ON WOOD COMPONENT5.
<br />MAX 5PACING 4"
<br />1 X 8 PAINTED WE). CAP
<br />STRINGER 15 LAMINATED TO A THICKNE55 EQUIVALENT TO
<br />OGEE 5TOP
<br />THE 51ZE OF A 2 X 12 5.Y.P. AND 15 NAILED TO EACH
<br />TREAD W/ 16d NAILS FROM THIRD LAMINATE TO TREAD—
<br />OPT, 2 X 2 BLOCKING NAILED
<br />TO TREAD AND R15ER.
<br />3-2 X 12 STRINGER
<br />2 X BLOCKING NAILED TO STRINGER, +
<br />3/4" RISERS
<br />R15ER, AND TREAD. + + +
<br />2 X TREADS± RIP FROM 2x12
<br />I X 5PRUCE 03 OR 3/4" CDX. + +
<br />TO 51ZE NOTED ON PLAN
<br />PLYWD. R15ER. +
<br />2 X 5OUTHERN YELLOW PINE #
<br />(ACTUAL THICKNE55 15 1 1/2") TREAD.
<br />TYP. OPT. RAILING ELEVATION CLOSED RISER DETAIL
<br />SCALE: I/2" = I' 0" 50ALE: 1/2" ; I'-0"
<br />"'�WEL P05T
<br />)P RAILING
<br />�LU5TER 4" O.C.
<br />10E RAIL (REMOVE
<br />METAL 5PINDLE5)
<br />8 PAINTED WE). CAP
<br />aEE STOP
<br />11 a-mam 1 OoR LINE
<br />4-
<br />OPTIONAL
<br />v:
<br />TREAD
<br />om
<br />2X4WALL
<br />1/2" GYP BD,
<br />3/4" 5KIRT BD.
<br />2 X 4 SPACER
<br />2X12
<br />STRINGER
<br />TYPICAL STAIR
<br />FRAMING DETAIL
<br />B 5CALE: 3/4" = 1411
<br />GENERAL CONSTRUCTION NOTES
<br />CHAPTERS AND SECTIONS REFER TO F.B.C. RESIDENTIAL 6th EDITION (2011)
<br />MECHANICAL AND HVAC
<br />I. ENERGY GALCULATION5 FOR HEATING AND COOLING CAPACITIES 5HALL BE FURNI5HED BY THE GENERAL CONTRACTOR A5 AN ATTACHMENT TO
<br />TH15 PLAN 5ET AT THE TIME OF APPLICATION FOR PERMIT.
<br />2, MECHANICAL APPLIANCE5 5HALL BE ACCE5515LE FOR INSPECTION, 5ERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT
<br />CON5TRUCTION, OTHER APPLIANCE5, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING IN5PECTED, SERVICED,
<br />REPAIRED, OR REPLACED, A LEVEL WORKING 5PAGE AT LEAST 30 INCHE5 (162 mm) DEEP AND 30 INCHE5 (162 mm) WIDE 5HALL BE PROVIDED IN
<br />FRONT OF THE CONTROL 51DE TO 5ERVICE AN APPLIANCE.
<br />3. DUCT5 IN THE GARAGE AND DUCT5 PENETRATING THE WALL5 OR CEILING5 5EPARATING THE DWELLING FROM THE GARAGE 5HALL BE
<br />CONSTRUCTED OF A MIN. % GAUGE (0.48 mm) 5HEET STEEL OR OTHER APPROVED MATERIAL AND 5HALL HAVE NO OPENINGS INTO THE GARAGE.
<br />4, FOUNDATION5 AND 5UPPORT5 FOR OUTDOOR MECHANICAL 5Y5TEM5 5HALL BE RA15ED AT LEAST 3 INCHE5 (16 mm) ABOVE THE FINI5HED
<br />GRADE AND 5HALL AL50 CONFORM TO THE MANUFACTURER'5 INSTALLATION IN5TRUCTION5.
<br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDEN51NG APPLIANCE5 5HALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO
<br />ANY BUILDING COMPONENT WILL OCCUR A5 A RESULT OF 5TOPPAGE IN THE CONDENSATE DRAIN PIPING 5Y5TEM, THESE PANS 5HALL BE
<br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVI51ON5 OF 5ECTION5 M1411.3.
<br />EXHAUST FANS AND VENTING
<br />(.OUTDOOR D15CHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST 5Y5TEM 5HALL BE D15CHARGED TO THE OUTDOOR5. AIR SHALL
<br />NOT BE EXHAUSTED INTO AN ATTIC, 5OFFIT, RIDGE VENT OR CRAWL 5PAGE.
<br />2, EXHAU5T AIR FROM BATH ROOM5 AND TOILET ROOMS 5HALL NOT BE RECIRCULATED WITHIN A RE5IDENCE OR TO ANOTHER DWELLING UNIT AND
<br />5HALL BE EXHAUSTED DIRECTLY TO THE OUTDOOR5. EXHAU5T AIR FROM BATHROOM5 AND TOILET ROOMS 5HALL NOT D15CPARGE INTO AN ATTIC,
<br />CRAWL 5PAGE, OR OTHER AREA5 IN51DE THE BUILDING.
<br />3, DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAU5T DUCT 5HALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE
<br />WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT 5HALL BE REDUCED 2.5 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND
<br />AND 5 FEET (1524 mm) POP, EACH 90 DEGREE (1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAU5T DUCT DOES NOT INCLUDE THE TRANSITION
<br />DUCT.
<br />EXCEPTION - WHERE A GLOTHE5 DRYER B005TER FAN 15 INSTALLED AND L15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF
<br />THE EXHAU5T DUCT, INCLUDING ANY TRAN51TION DUCT, 5HALL BE PERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FAN MANUFACTURER'S
<br />INSTALLATION IN5TRUCTION5. WHERE A CLOTHE5 DRYER B005TER PAN 15 INSTALLED AND NOT READILY ACCE551BLE FROM THE ROOM IN WHICH
<br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL 5HALL BE PLACED ADJACENT TO WHERE THE EXHAU5T DUCT ENTERS THE WALL. THE
<br />LABEL 5HALL BEAR THE WORD5 "TH15 DRYER EXHAU5T 5Y5TEM 15 EQUIPPED WITH A REMOTELY LOCATED 5005TER FAN."
<br />4, PROVIDE LOUVER DEVICE5 AT INTAKE AND EXHAU5T LOGATION5 IN ACCORDANCE WITH
<br />AMCA 5TANDARD 550 IN FBC.
<br />ROUGH -IN IN5RECTION REOUE5T NOTE
<br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH=IN5 MUST BE
<br />COMPLETE, IN5PEGTED AND APPROVED BEFORE REQUE5TING THE
<br />FRAMING INSPECTION.
<br />WINDOW FALL PROTECTION
<br />IN DWELLING UNIT5, WHERE THE OPENING OF AN OPERABLE WINDOW 15
<br />LOCATED MORE THAN 12 INCHE5 ABOVE THE FINI5HED GRADE OR
<br />SURFACE BELOW, THE LOWE5T PART OF THE CLEAR OPENING OF THE
<br />WINDOW SHALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINISHED
<br />FLOOR OF THE ROOM IN WHICH THE WINDOW 13 LOCATED. OPERABLE
<br />5ECTION5 OF WINDOWS SHALL NOT PERMIT OPENING5 THAT ALLOW
<br />PA55AGE OF A 4 INCH DIAMETER SPHERE WHERE 5UGH OPENING5
<br />ARE LOCATED WITHIN 24 INCHE5 OF THE FINISHED FLOOR PER F.B.C.
<br />RESIDENTIAL 6th EDITION (2011) - SECTION R312.2.
<br />WINDOW FALL PREVENTION DEVICES AND WINDOW GUARD5, WHERE
<br />PROVIDED, SHALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090
<br />PER F.B.G. RESIDENTIAL 6th EDITION (2011) - 5ECTION R312.2,
<br />INSULATION NOTES
<br />• GMU WALL5:--==- R=FOIL 4.1 KNEE WALL5 THAT
<br />BACK UP TO CEILING
<br />• FRAME WALLS: ---- =--= R-13 AREA ONLY: ==== --- =__= R-19
<br />• CEILING:------------- R-30
<br />ON51TE FOUNDATION 5URVEi NOTE
<br />A FOUNDATION SURVEY 5HALL BE PERFORMED AND A COPY OF THE
<br />SURVEY 5HALL BE ON THE 51TE FOR THE BUILDING IN5PECTOR'5 U5E,
<br />OR ALL PROPERTY MARKERS 5HALL BE EX1305ED AND A STRING
<br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED
<br />5ETBACK5,
<br />CLING AT ENTRY' NOTE
<br />ALL ENTRY GLG5. TO BE 15/32 058, CEMENTITOU5 FIN15P (U.N.0)
<br />GA5 APPLIANCE PROTECTION IN 6ARA6E NOTE
<br />PROTECTION OF 6A5 APPLIANCES IN RESIDENTIAL GARAGES:
<br />MINIMUM 3" DIAMETER 5CH 40 5TEEL PIPE, 2 FT. BELOW CONCRETE
<br />SLAB AND 3 FT. ABOVE FIN15PED FLOOR,
<br />GENERAL NOTES
<br />• DUE TO VARIATIONS IN CITY REQUIREMENT5, 5UBDIV1510N
<br />5PECIFICATION5, CON5TRUCTION TECHNiQUE5, DIVER5ITY IN
<br />MATERIAL5, AND PLAN REV1510N5, ALL DIMEN5ION5 AND
<br />ELEVATIONS MAY VARY PER INDIVIDUAL PLAN, ACTUAL FIELD
<br />CONDITION5 MAY VARY AND MUST BE VERIFIED BEFORE
<br />PROCEEDING WITH CON5TRUCTION.
<br />• ELECTRICAL LOCATION5 5HOWN ON DRAWING5 MAY BE CHANGED
<br />AT THE 50LE D15CRETION OF CALATLANTIC HOMES OR IT5
<br />LICEN5ED ELECTRICIAN IN ORDER TO COMPLY W/ NATIONAL AND
<br />MUNICIPAL BUILDING AND ELECTRICAL CODES. CALATLANTIC
<br />HOME5 WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLET5
<br />AND / OR 5WITCHE5 5HOWN.
<br />• ALL PLUMBING DIMEN51ON5 ARE APPROXIMATE FROM THE CENTER
<br />LINE OF THE FIXTURE TO THE EXTERIOR SLAB EDGE. IT 15 THE
<br />RE5PON515ILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF
<br />ALL PLUMBING DIMEN51ON5.
<br />NOTE: ANY DIMEN51ON5 AND/OR CALLOUT5 WITHIN TH15 5ET OF DRAWING5 REFERENCING
<br />LUMBER 51ZE5 OR WALL THICKNE55E5 ARE TO BE CON5IDERED "NOMINAL DIMEN51ON5"
<br />CHIMNEY HINT R OUIREMENT5:
<br />WHEN STANDARD OR OPTIONAL FIREPLACE 15 TO BE INSTALLED THE CHIMNEY MU5T EXTEND 3'-0" PAST THE HIGHER POINT WHERE IT
<br />EXTENDS THROUGH THE ROOF AND MUST BE 2'=0" HIGHER THAN THE ROOF OR RIDGE THAT 15 10'-0" AWAY OR CL05ER.
<br />TUE AND 5HOWER ARE45:
<br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH A5TM Cl286, CI325, OR CIIIE
<br />AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION5 5HALL BE U5ED A5 BACKER5 FOR WALL TILE IN TUB AND
<br />SHOWER AREAS, AND WALL PANEL5 IN 5HOWER AREA5.
<br />FLOOD ZONE REOUIREMENT5:
<br />PLAN MEET5 OR EXCEEDS FEMA FLOOD FINI5HED GARAGE FLOOR ELEVATION.
<br />BEWS
<br />DESIGN GROVP
<br />150 STATE STREET' FAST
<br />OLDSMAR, FLORIDA 34677
<br />813.925. 130d TEL
<br />813 . 925.1800 FAX
<br />W W W.DAVLSBEWS.COM
<br />TAMPA • DEiWER.
<br />� EST. 1994
<br />s
<br />0
<br />zC)
<br />N
<br />0
<br />1-4
<br />��
<br />�V)Mo
<br />mac% M�
<br />a �Ln
<br />Q a�
<br />M
<br />Q U Q�
<br />.�
<br />ZC)H
<br />wwo
<br />J �
<br />d-
<br />J
<br />Oz
<br />�o
<br />W
<br />za
<br />z�
<br /><a
<br />WQ�ft
<br />oQgo
<br />J
<br />o W cy
<br />u J
<br />aC2u-o
<br />O W � N
<br />W �Wo
<br />o(n
<br />Q zz
<br />}O
<br />�z
<br />W
<br />Z ��
<br />0 Q J
<br />Q
<br />QC z
<br />W
<br />T-+ Lu
<br />z Q ow
<br />z `-'
<br />z U Z z0
<br />J O
<br />ui z j CD
<br />z Q L
<br />m z w =
<br />O 0- w � m
<br />SCALE : AS NOTED
<br />DATE : 10-19-2018
<br />VERSION NO.
<br />imo
<br />SHEET NO.
<br />DT1
<br />DAVIS
<br />I� 1