Laserfiche WebLink
(2) TYP. <br />G <br />I♦ <br />25' —OI I <br />I I OVERHANGS OVERHANGS <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSH CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 25 ft <br />VIND SPEED (ULTIMATE) 140.0 MPH <br />VIND SPEED (ALLOWABLE) 108.4 MPH <br />XPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) <br />WIND AREA (+) VALUE DENOTES PRESSURE HIP ROOF >20 TO 45 DEG. <br />(SQ FEET) O VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=oft <br />AREA ROOF 1 2e 2n 2r 3 3e 3ra <br />10 HIP -35.94 -49.57 1 -49.57 49.57 / <br />GABLE -38.22 -38.22 -60.99 1 -60.99 1 -60.99 -78.58 —----�— / <br />I. <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />I <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.G. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />Q <br />SHINGLE: %s' EXP. 1 (24/6) or 1Y32" EXP. 1 (3y16) <br />9I <br />TILE: t%2" EXP. 1 l�37�16} I <br />NOTE: i <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 Y8" x 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1.732', SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 1 Od (2Y2" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3" x. 120") NAILS a=oft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER GABLE ROOF > 20 TO 45 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING [4:12]-[12:12] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 -10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795(2)PLY <br />9 - 1 Od x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />1 585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 -10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 -10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 1 Od x 1 1/2% 8-1 Od <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 10dxl-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8-10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 -16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />-- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 1 Od x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-1 Od x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -1Od x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -1 Od x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />(2) LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w/ (32) 16D SINKERS & <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ (32) 16D SINKERS & <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />'W' <br />HTS 20 <br />1310 <br />1245 <br />24-1 Od x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-1 Od x 1 1/2" <br />SP1 <br />555 <br />535 <br />10 - 10d <br />$PT22 <br />735 <br />8 - 10d <br />SP2 <br />1010 <br />605 <br />12-10d <br />SPT24 <br />1090 <br />12-10d <br />HCP2 <br />590 <br />555 <br />12-1 Od x 1 1/2" <br />HHCP2 <br />680 <br />570 <br />(20)1 Od x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. <br />REVISED 12-02-20 <br />LOADS -- ROOF = L 1360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (* ). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 54" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />j (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />2 PLY <br />BIER <br />f <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />ROOF FRAMING PLAN - ELEV-13 <br />SCALE: 14"=1'-0" <br />e� <br />�V <br />c+ <br />r <br />CD o <br />N. W <br />c cvwN <br />d+- <br />c 0- <br />in co c .. <br />10 CV S <br />N � O <br />� OD <br />c c <br />as � � •cs <br />Cc <br />= ,� 5 u Flu <br />;= � cc� <br />c � <br />06. <br />M <br />O <br />CV <br />CV <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />M <br />W <br />a0 <br />o E <br />co <br />e+ <br />U <br />6 N to <br />y- <br />•/ <br />LL7 N <br />h J <br />to <br />4 <br />C13 <br />C) <br />�m� � "- <br />J LL W <br />u 3 a <br />— o a 4 <br />`m <br />x <br />c <br />_ <br />a�yy <br />itIL W <br />� m o 0 <br />7 f6 N � <br />-;s; <br />C5 m <br />Z <br />LLui <br />c . W <br />� Mz Q <br />aN <br />0 <br />U <br />zO <br />U <br />❑ ❑ <br />O O <br />W co <br />QNN <br />O Q <br />u4 <br />U) <br />I <br />— N <br />M <br />v <br />�V <br />� LL <br />_ <br />L <br />OLU <br />to <br />o <br />Y <br />V) <br />ZD <br />N <br />U a <br />LLI J <br />P— — E <br />8 <br />Ub". <br />i!3 <br />U <br />< N m <br />o <br />w <br />to <br />cl-� <br />M <br />J <br />z <br />O <br />z <br />z <br />Q <br />U_ <br />O <br />� U <br />Z o <br />g p <br />of <br />Z o <br />G N <br />z ® <br />as <br />F� f6 <br />o <br />00 <br />oa <br />o� <br />CO ro <br />s <br />�o <br />a <br />�z <br />w <br />en <br />C <br />as¢ <br />p U <br />M. <br />H� <br />zI <br />2! <br />m J <br />'M¢w <br /><� <br />o< <br />�z <br />g0 <br />V) <br />3 <br />t <br />a z <br />NW <br />m <br />az <br />�z <br />c9r <br />O <br />M <br />v <br />w F <br />> <br />d <br />zl< <br />° <br />c <br />0 <br />>M <br />Om <br />M <br />co L.n <br />r <br />N <br />CL <br />Lr) <br />Q <br />Cr <br />00 <br />N <br />U) <br />�-m <br />+-+ <br />0 <br />_ <br />.a--+ <br />r*1 <br />d' <br />U CY) <br />O <br />p <br />.Q <br />co <br />M o <br />-� <br />N <br />N <br />Q <br />N <br />r <br />C LO <br />0 <br />z <br />co <br />U) <br />z <br />E r <br />a <br />a <br />U <br />Q p <br />JOB <br />NO: <br />23-04906 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />6.2 <br />