ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA t <br />200 AMP <br />#12 copper to 20 amp ckts <br />01 #10-2 copper to WH <br />01 #10-3 copper to Dryer <br />METER <br />MO2/0 <br />or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqT- <br />DUPLEX OUTLET ABOVE COUNTER <br />W,P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q+ <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />0 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />VI] <br />ELECTRIC METER <br />mpg_ <br />ELECTRIC PANEL <br />_ I <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />V J <br />�/> <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />WP DISC. DEDICATED RECEPTACLE <br />GFI H.B. FOR MICROWAVE RANGE <br />Ak t HOOD PER SPECS <br />ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />B E LJ R OLIG�HT PRE -WIRE <br />GFI <br />RECEPT. / <br />FOR ALARM —/ VERIFY METER H.B. <br />SYSTEM LOCATION WITH <br />BUILDER <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />V <br />r <br />M <br />� <br />QQQ <br />J <br />n.. <br />tnnn' <br />4--J LLJ <br />d <br />OLLJ <br />0 <br />$co <br />r- <br />LJ <br />m <br />t9J <br />o <br />0M M <br />N M COt— <br />N <br />O om <br />cLL. <br />O Y I` <br />U)o� <br />< 0QAwl <br />o <br />n c <br />I--L,7/ <br />� O <br />co <br />� co <br />go4 N <br />O <br />z o1 <br />Z m Z <br />W O <br />LL Z <br />LL <br />ii t11.15 <br />N <br />"' <br />W <br />LU <br />UV¢ouL <br />�W <br />z <br />N �q¢ <br />O <br />mm <br />LLZ �o~o <br />a�¢N <br />W N <br />-� <br />� O <br />U <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z N <br />0 N <br />Ili M O <br />M <br />Q U-) Lf) <br />IZ toZ •0 d- <br />V) <br />Q 0)0L) <br />rL <br />M <br />DC U CL 00 <br />Q <br />E � <br />z�� <br />W <br />J <br />� <br />oZ <br />o <br />W� <br />za<L <br />�x <br />F <br />zWaI.L�S& <br />UzOo <br />J <br />IZ <br />i Z <br />W <br />J <br />J <br />�&�W <br />r—� <br />Q <br />y o_prn <br />Oc4LL o <br />UL o <br />U <br />Zz <br />zp <br />■ <br />ir— <br />� <br />Z <br />Z <br />"� <br />Z <br />"0 <br />LJ <br />z <br />IM <br />W <br />o <br />Z <br />O <br />O <br />LU <br />V <br />(J) <br />f <br />O <br />w <br />Ow <br />¢UOU� <br />--u <br />� � <br />u <br />7 <br />Z <br />w0o� <br />vania <br />� <br />N <br />-�za <br />Q <br />0ga <br />Z <br />Wok <br />Z <br />N <br />Lr% <br />Lu CY <br />W <br />tL <br />2:Q <br />WC <br />G <br />�a�SO <br />8 Z SO <br />LU F8 <br />Ln <br />M <br />Q <br />Z <br />�wZ <br />Z <br />aZ <br />mObI <br />�o <br />� <br />_ <br />,-+ <br />a <br />V) <br />SCALE : AS NOTED <br />DATE : 1 /4/2018 <br />TECH: ERAND <br />VERSION NO. 2x0 <br />SHEET NO. <br />4.0 <br />