Laserfiche WebLink
INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />1 <br />COVER SHEET <br />2 <br />UNIT 1397 FLOOR PLAN <br />3 <br />UNIT 1500 FLOOR PLAN <br />4 <br />BUILDING PLAN (Left) <br />5 <br />_ —T <br />BUILDING PLAN (Rights — <br />6 <br />EXTERIOR ELEVATIONS <br />7 <br />UNIT 1397 ELECTRICAL PLAN <br />8 <br />UNIT 1500 ELECTRICAL PLAN <br />9 <br />FOUNDATION PLAN <br />10 <br />ROOF FRAMING PLAN <br />10.1 <br />ROOF PLAN <br />L1 <br />LINTEL PLAN & DETAILS <br />ABBREVIATIONS <br />_ — <br />FP-1 <br />FIRE PROTECTION DETAIL <br />; <br />SIN <br />STRUCTURALNOTES <br />AB or A.B. Anchor Bolt <br />FIX or FXD Fixed <br />PWDR or Pwd. Powder Room <br />SN 1 <br />DETAILS <br />ABV or Abv. Above <br />FLR or Fir. Floor <br />RA or R/A or R.A. Return Air <br />- <br />AC or A1C Air -Conditioner <br />ADJ or ADJ. Adjustable <br />FLR SYS or Fir Sys Floor System <br />FOM or F.O.M. Face Of Masonry <br />RAID or Rad. <br />RAG or Rag. <br />Radius <br />Return Air Grill <br />_ <br />S3 <br />--"----- -- <br />MONO DETAILS <br />AFF orA.F.F. Above Finished Floor <br />FP r F.P. Fireplace <br />oREC <br />or Rec. Recessed <br />_ _ <br />AHU or A.H.U. Air Handler Unit <br />FIR DR French Door <br />RECEPT <br />Receptacle <br />- <br />--- - - - <br />ALT orALT. Alternate <br />BC Base Cabinet <br />BF Bifold Door <br />BK SH or Bk Sh Bookshelf <br />BILK or BILK. Block <br />BLW orm. Below <br />BM or Bm. Beam <br />BOT or Bot. Bottom <br />BP or B.P. Bypass (door) <br />FRT Front <br />FT or Ft. Foot/ Feet <br />FTG or Ftg. Footing <br />FXD GL Fixed Glass <br />GALV or Galv. Galvanize d <br />GC or G.C. General Contractor <br />GFI or G.F.I. Ground Fault Interrupter <br />p <br />GT or G.T. Girder Truss <br />GYP BD or Gyp. Bd. Gypsum Board <br />REF or Ref. <br />REINF <br />REQD or Req'd. <br />RM or Rm. <br />R or Rnd <br />NDIN <br />RS, or R.O. <br />IRS, RIS, R/SH or R&S <br />SD or SD. <br />SGD <br />Refrigerator <br />Reinforcing <br />Required <br />Room <br />Round <br />Rough Opening <br />Rod and Shelf <br />Smoke Detector <br />Sliding Glass Door <br />_ <br />� � _ r _' <br />S5 <br />__ <br />SS <br />----- <br />D1 <br />WP <br />---- -- <br />PA1.0 <br />- - <br />PA1.1 <br />DETAILS <br />_ <br />RETROFIT DETAILS <br />- ---- ---- ---- - -- --- --- <br />FRAMING DETAILS <br />WATERPROOFING DETAILS <br />-- — — ----- - ---- - -------------- <br />PRODUCT APPROVAL NUMBERS <br />PRO UC O U <br />- - <br />PRODUCT APPROVAL NUMBERS <br />_ �i <br />DD ®DDD <br />0D®0 ®DD0 <br />DDCD <br />®CD . -i �CD <br />DD�0 <br />CDCD CD®0 <br />®® <br />�000301, <br />�� <br />®® <br />��M <br />®® <br />®® <br />, .. .., <br />': ... .-. ... :..a <br />s <br />••�� • '••'�• - �' _ �<' � • <br />_ <br />• DD00 <br />_ . <br />_ <br />S. <br />� •• •'µ <br />-� <br />CD_ � <br />.. <br />.. <br />�• <br />• <br />,r <br />D�DD <br />` <br />r <br />�DD� <br />.. <br />- <br />,. <br />- <br />a: <br />'° <br />e r <br />••' • -� <br />..,.;. .. .,... <br />.. s.. J :... ....-. .. .e i .. �. ... <br />^ �� - ,,,,,-> <br />BRG or BRG. Bearing <br />HB Hose Bibb <br />SH orSh. <br />Shelves <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />C Carpet <br />CAB Cabinet <br />HDR or Hdr. Header <br />HGTorHgt. Height <br />SHT <br />SHWRorShwr. <br />Sheet <br />Shower <br />- <br />PA1.3 <br />-- -------------- ---------------- <br />PRODUCTAPPROVALNUMBERS <br />CIR or Cir. Circle <br />HH or H.H. Hand Held (plumbing faucet) <br />SL or S.L. <br />Side Lights <br />SH1.0 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CJ or C/J Control Joint <br />HORIZ Horizontal <br />SPECS or SPECS. <br />Specifications <br />----. <br />------------ --------------------------------------- <br />CLG or Clg. Ceiling <br />HS Hard Surface (flooring) <br />SPF or S.P.F. <br />Spruce Pine Fir <br />SH1.1 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />_ <br />CMU Concrete Masonry Unit <br />COFF or Coff. Coffered or Tray Ceiling <br />ILO In Lieu Of <br />INSUL or Insul. Insulation <br />SQ FT or SF or S.F. <br />SQ orSq. <br />Square Foot (feet) <br />Square <br />� 6 <br />UNIT TOWNHOMES <br />--_- <br />SH1 2 <br />- --------- — - __. <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COL or Col. Column <br />INTorInt. Interior <br />STO <br />Storage <br />SH1.3 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COMM or Comm. Community <br />COMP or Comp. Compressor <br />KMIALL or KNWall Kneewall <br />KS or K.S. Knee Space <br />SW or S.W. <br />SYP or S.Y.P. <br />Shear Wall <br />Southern Yellow Pine <br />------_-- <br />SHI A <br />-- -- -------- -- - --- - <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.5 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CONN orCONN. Connection <br />LAUN or Laun. Laundry <br />TB Towel Bar <br />CONT or Cont. Continuous <br />LAV or Lav, Lavatory <br />TEMP or Temp. <br />Tempered <br />— - <br />- --- --------------- <br />CT or C.T. Ceramic Tile <br />LF or L.F. Linear Ft. <br />THIKN or Thik'n. <br />Thicken <br />D or D. Dryer <br />LL Lintel Length <br />TOB or T.O.B. <br />Top of Block <br />DB Door Bell <br />LT Laundry Tub <br />TOM or T.O.M. <br />Top of Masonry <br />DBL or Dbl. Double <br />MAS or Mas. Masonry <br />TOP or T.O.P. Top of Plate <br />DCF Decorative Cementitious Finish <br />MAX or Max Maximum <br />TP <br />Toilet Paper Holder <br />DEC or Dec. Decorative <br />MC Medicine Cabinet <br />TR <br />Towel Ring <br />DED or Ded. Dedicated (outlet) <br />MFR or Mfr. Manufacturer <br />TRANS WDW or Trans. Transom Window <br />DIA or Dia. Diameter <br />MGT Management (room) <br />TYP or Typ. <br />Typical <br />-- ----- -- - -- - -- - - - - - --- - _— -- <br />---- <br />DISP or.Disp. Disposal <br />MIN or Min Minimum <br />UC or u.c. <br />Under Counter <br />DIST or Dist. Distance <br />MIR or Mir. Mirror. <br />UCL Under Cabinet Lighting <br />DMF Decorative Masonry Finish <br />MIL or M.L. Microlam <br />LINO or U.N.O. <br />Unless Noted Otherwise <br />- <br />- ---- - ---- -- -- - - -- <br />DS or D.S. Drawer Stack <br />MONO or Mono Monolithic <br />V or v. <br />Valve (shower or tub/shower) <br />DTL Detail <br />MW or MICRO or Micro. Microwave <br />VB <br />Vanity Base <br />DV or D.V. Dryer Vent <br />NTS or N.T.S. Not to Scale <br />VERT or Vert. <br />Vertical <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />DVP or D.V.P. Diverter Valve (plumbing) <br />OE or O.E. Owner's Entry <br />VL or V.L. Versalam <br />DWorD.W. Dishwasher <br />OPNGorOpn'g. Opening <br />VTR orVTE <br />Vent through Roof/Exterior <br />FOR SINGLE STORY HOMES <br />EA or Ea. Each <br />OPT or Opt. Optional <br />W or w <br />Washer <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />ELEC or Elec. Electrical <br />ELEVorElev. Elevation <br />EQ Equal <br />PC Pull Chain <br />PEDorPed. Pedestal <br />PH Phone <br />W/orw/ <br />WA or W.A. <br />WC or W/C or W.C. <br />With <br />Wedge Anchor <br />Water Closet (toilet) <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />E LED OR WHILE <br />IS SIGNED AND SEALED <br />EWorE.W. Each Way <br />EXP or Exp. Expansion <br />EXTorExt. Exterior <br />FBC Florida Building Code <br />PKTorPkt. Pocket (Door) <br />PL or P.L. Parallam <br />PLF Pounds per linear foot <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />WDorWd Wood <br />WDW HDR or WDW. HDR. Window Header <br />WHorW.H. Water Heater <br />WIC or W.I.C. Walk-in Closet <br />FDN or Fdn. Foundation <br />PLT HT or Pit. Ht. Plate Height <br />WM or W.M. <br />Wall Mounted (plumbing fixture) <br />CURRENT CODE VALID <br />CODE REFERENCES ARE SUMMARIES <br />FG Fiberglass (Shower Pan) <br />PSF Pounds per square foot <br />WP WaterProof(ing) <br />FIN Finished <br />FIN FLR or FF or Fin. Fir. Finished Floor <br />PT or P.T. Pressure Treated <br />PWorP.W. Pre -wire <br />WS <br />WWF <br />Water Softener <br />Welded Wire Fabric (Mesh) <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION <br />PLAN <br />REVISIONS <br />DATE VERSION DESCRIPTION <br />Notice to Builder & All Subcontractors <br />it is the intent of DesignerlEngineeriisted in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />01 /2 1 / 1 1 1.0 NEW CONFIGURATION <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />08/22/ 1 1 1.1 <br />REV 1 501 KITCHEN <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />09/ 14/ 11 2.1 <br />VALUE ENGINEERING REVIEW <br />undetected and not reported to the Designer /Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />01 / 1 9/ 1 2 3.1 <br />S HAFT L I N E R DETAILS <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />03/ 16/ 12 4.1 <br />BUILDING CODE UPDATE <br />Payments will be made in accordance to the terms of the <br />agreement. <br />12/19/20 5.1 FBC 2020 CODE UPDATE <br />Control of construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />02/ 18/22 5.2 <br />NEW PLAN NUMBERS <br />PER C.M.ny <br />manner for control n the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. <br />.4� <br />,ae9 <br />cue <br />> W <br />C3 o <br />x <br />M,C= r <br />y - C4 .0 <br />3 <br />�z Q. <br />E <br />co,, o <br />RE% 1�o <br />1 <br />• ....... <br />r <br />n((jJj //I rYV/ql� <br />672- <br />7 y <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />0 <br />4 3 <br />O N <br />0 <br />00 4 N W <br />0 <br />N CnM0.� u- <br />a- J LL U 3 LL o <br />3 <br />a <br />- <br />Z 2 � _ m m . <br />I @ o o <br />W 0 m N 0 O <br />cp. <br />m Lu <br />Z aD N 0 d <br />ILWco <br />Z N 00 o0 <br />W ❑1:1 <br />2 N O <br />o <br />� N <br />z o � <br />r, <br />y ^ M <br />v I <br />Ah C <br />lJ p <br />4­, <br />NAM <br />Ou, o <br />N <br />r-- <br />MINW J <br />° <br />�q <br />S L <br />0 o <br />m <br />o <br />w <br />tCi <br />M <br />¢ <br />zo� <br />z <br />co E <br />O <br />pwo <br />O <br />u.. <br />~c= <br />z <br />Q N <br />ZOO <br />oa <br />oo <br />D0 <br />o <br />N <br />az <br />o <br />� <br />wW <br />tr <br />� <br />z <br />� <br />mo <br />C <br />_ c <br />oY <br />o, <br />Z <br />'z <br />z <br />z <br />o< <br />Z <br />go <br />N { <br />5 <br />> <br />U. <br />�0L <br />a <br />w <br />CD<a <br />o <br />a <br />0 <br />2 N <br />LO <br />CID <br />ai <br />m <br />ca <br />O <br />> O <br />0 <br />J <br />r <br />T <br />N <br />0 <br />Q <br />u <br />Cr <br />CC,-- <br />M <br />60 <br />U) m <br />o <br />0 N <br />LO <br />(0 <br />00 p <br />C� <br />E <br />CN <br />O <br />05 <br />Q CN M L <br />C600®00 <br />ai <br />r <br />M <br />CO <br />0 <br />z <br />z <br />E <br />E <br />FL <br />0 <br />U Q <br />JOB <br />NO: 22-09484-09479 <br />SCALE : AS NOTED <br />SHEET NO. <br />