Laserfiche WebLink
• °+' SYMMETRICAL <br />GENERAL CONCRETE LINTEL SCHEDULE <br />• • • °'° ''° APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY <br />cr <br />8F8-1 B/1 T <br />8F8-0B/1T O H H E <br />E H <br />aar� <br />O � `_�•° TYPE DESIGNATION #5REBAR ATTOP � �-• <br />F = FILLED WITH MIN. (1) REQ'D <br />• • • • GROUT / U = UNFILLED a <br />® <br />8RF14-1B/1R RECESSED T8RF14-OB/1T ° CLEAR <br />, <br />= - ci cu` ca•-s-, <br />O "' <br />REBAR @BOTTOM ° <br />OF LINTEL CAVITY ~ <br />„• .d . ° U y <br />° v •�. ,�, ,4L a M. N dN m <br />Ua E >Es <br />_ R aZ O D D <br />8 F 16 B/ 1 T o°° ° MS25 O -= <br />cz <br />;,,'° ' ZZ d ° GROUT co a/ SO <br />3 <br />:'r • :'> : •° • QUANTITY OF ° '= c° <br />•' ,-•'•` tNOMINAL.5REBARAT <br />• • • • • • • • WIDTH #5 REBAR AT ° O BOTTOM OF <br />TOP LINTEL CAVITY <br />8F20-OB/1T 8F20-1B/1T8F16-013/1T 8F16-16/1T NOMINAL ° "*-BOTTOM <br />G O O HEIGHT REINFORCING <br />© O cD <br />7-5/8"ACTUAL PROVIDED IN <br />8" NOMINAL WIDTH LINTEL O <br />- (VARIES) <br />MATERIALS <br />1. fc precast lintels = 3500 psi. <br />• ° • ` ° ° ` ° , ; ° ° ° ' " ° ' 2. f'c prestressed lintels = 6000 psi. gy��l,, <br />'8RF6-OB/1 T 3. grouted per ASTM C476 fg = 3000 psi w/ `�.�` 'ago <br />° s', 4. maximum 3/8" aggregate and 8" to 11" slump. _ tom. <br />© _ 5. Concrete masonry units (CMU) per ASTM C90 w/ O <br />minimum net area compressive strength = 1900 psi. <br />U0, <br />, , .. v , ; 6. Rebar per ASTM A615 Grade 60. n "° ° �.0 <br />Prestressing strand per ASTM A416 gradeCA,7. 270 low relaxation. ` ° °. • °. ° 7/32 wire per ASTM A510.O C <br />'. • • ;' 8. Mortar per ASTM C270 type M or S. <: <br />8F20-1 B-2T • °'� ° • •'• O R c., `` f, �3 <br />° :0 • • • • GENERAL INSTALLATION NOTES <br />; <br />© ° Provide full mortar head and bed joints. <br />8RF22-1 B/1 T 8F24-OBl1 T 8F24-1 B/1 T 2 <br />, Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />O <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />. ° vertical cell reinforcing and grouting. <br />All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. 3 <br />° ' . ° , ° ,'° a v s', , _ �', , • d', , ° , ° ;', ; . 7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. o <br />°° °: , : 8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete - <br />' .•° �° •'� °'' ^'' �'- . ° , '' �' masonry units. <br />r o FP-1 <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 coo T ~ 3 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630:16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />° . ° '. • '. °°- • : ° • ° a coating of stucco applied in accordance with ASTM C-926 or other approved o FP-1 <br />Lo <br />' coating. 00 B LL - <br />12. All lintel dimensions shown are "overall" lintel lengths. O oo <br />vL <br />13. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) r 3 <br />° ° ° ° loads shoud be checked for combine loading with the following equation: r <br />° ° • ' d ° ° ° ° ° ° ° Applied vertical load Applied horizontal load FP-1 To the best of the Engineer's knowledge, information and belief, <br />s ° s ° s • e ° . s ° s ° e • ° . ° - \�R) the structural plans and specifications contained within these <br />-f �� . 0 drawings comply with the 2020 Florida Building Code - <br />�,•° �•° • i r • `•° - U'!'L <br />Safe Vertical load Safe horizontal load cb Residential 7th Edition. Engineers signature and seal is only for <br />dcbthe structural engineering portions of the drawing pages bearing <br />OEngineers signature and seal. <br />r H <br />• • • • • • • • • ° • • • • • • • W <br />8F441B/1T8F400B/1T 8RF400B/1T 8F321B/1T 8F32OB/1T 8RF301B/1T 8F28OB/1T 8F281B/1T a S N E o <br />® © ® © OU O OS 0 <br />0 <br />y cs D, <br />093I <br />ALTERNATE POWERS 0� M� <br />�� �� ai <br />LINTEL PLAN NOTES: _ Z ro @a a <br />STEEL LINTEL �� �� _ � 0 <br />ul <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL o 0 o m o co w <br />F ~ - Z 113 <br />N `�Z a - <br />INFORMATION ONLY.o <br />#5 REBAR AT TOP IL Z O U V O <br />MIN. (1)REQ'D `, 1-112"CLEAR 2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE �D <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. O <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED M <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE z o <br />w _ z �� <br />�� C.M.U. COORDINATED WITH THE ELEVATION DRAWINGS Q v <br />4. THE CONTRACTOR IS RESPONSIBLE FOR o o13 <br />CWXw �� i1 COORDINATING THE PROPER LINTEL HEIGHT. <br />�Oz r O O <br />ova: 5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM �,, "' "' �v N LL <br />CC ��� DEPTH REQUIRED FOR THE DESIGN LOADS. THE ``' I �_ W <br />O w cn � ,. 5 REBAR AT BOTTOM U <br />LL0 = AS INDICATED DEPTH MAY BE INCREASED IF REQUIRED FOR Oin <br />w o <br />N <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. N <br />16 GAUGE POWERS - `° <br />STEEL BOXED LINTEL C) c <br />W J <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) _ I <br />ONLY IF NOTED ON LINTEL PLAN POWER STEEL LINTEL IS AN ADEQUATE �' ��' c u, -® <br />1. Refer to manufacturer's specifications for installation. b O O o Q N o <br />2. Contractor to provide proper protection of lintel to prevent rusting. SUBSTITUTION ALL LOCATIONS UNLESS r O O O O z <br />Refer to manufacturer's specifications. o <br />w <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. NOTED OTHERWISE AT OPENING LOCATION `' z <br />4. Lintel depth to match precast depth. One #5 Bar required at top - = J < <br />see lintel plan/details for bottom steel required. O O `r U_ z <br />so <br />5. A bonding agent must be applied to the Steel Box lintels prior to 1- - - - Q E z o <br />applying the cementitiuos coating. See contractor specifications E u o ° o <br />X U U <br />2 Q O , <br />d W o w z <br />2" DIA. PIN #3 SHEAR REINFORCING mi <br />@ 16" O.C. <br />n Cx o' <br />K.O. BLOCK COURSE �� aw <br />O O OZ <br />_ oo w/(2)-#5 TOP, MIN (SOLID N � ~� �Z <br />� o< go <br />Q 3 a az <br />o LID <br />GROUT) G MIN. MIN. MIN. F3 <br />(2) #5 REBAR @ BOTTOM MJ <br />o w¢ <br />OF LINTEL CAVITY � 5 03 <br />UNIT 1500 UNIT 1397 UNIT 1397 SYMMETRICAL t N <br />PRECAST LINTEL UNIT <br />BY MANUF. <br />o > oCU <br />LO 0 <br />r - N <br />S25 LINTEL W/ SHEAR REINF. Mco 0 <br />N.T.S. REV 05.02.22 CAB 50 U) Cr <br />m Q Q <br />LINTEL PLAN T <br />CN <br />SCALE:3/16"=1'-O" o <br />� C> <br />Q Lo N N rn <br />N 0) U') Lo <br />Co l �00 <br />r <br />E :3o <br />M M N z <br />Z E a <br />cu <br />O p a N a)d U � Q p <br />JOB NO: 22-09484-09479 <br />SCALE : AS NOTED <br />SHEET NO. <br />L 1 <br />