Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />II II II <br />117 1k I Ias : aa:1::: : <br />X............ <br />I: d'..j.........1:1:::: I 11..... <br />I. <br />L:L....:.. IV-1 �......... .I..................I..1..... <br />I- >k......... . <br />I.... 1.1..................1.�..... <br />16GAx1-1\2 LONG (3/4 -1 CROWN) I I MAX 1--11 I <br />STAPLES @ 6" O.C. VERT BETWEEN " I .. 16GAx1-1/2 LONG (3/4' 1 <br />STUDS (NOTED THUS:—) - OFFSET I I I I I I CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF L� <br />HOME H C G <br />GARAGE SIDE 00 O <br />5'-0" <br />STUB -OUT FOR 1'-0" o 0 0 <br />GAS METER O o <br />U <br />O <br />N O <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" <br />5000s 1.8/1.7 <br />p nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-118" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />6500s 1.8/1.7 <br />Wood panels <br />2 x _ + 5/8" or 314" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />+ <br />FILL CELL STD. 90° HOOK BOND BEAM <br />/7 <br />Cn <br />w <br />Q STD. 90° CONT. #5 <br />BCONT. #5AR > HOOK BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />I ' <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />I OTHERWISE SOLID <br />TO MATCH <br />LBLOCKING <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. <br />} Small 2" min. <br />2" max <br />gap <br />4 max. <br />Clinch na <br />when <br />possible <br />J <br />ils <br />I <br />1) Support back of web during nailing to prevent damage to 77 <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %$' GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION <br />- Birdsmouthcuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. hi her than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 1 Od box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" I1 Od) nails at 6" o.c. <br />QY-' Provide adequate bearing <br />for each lapped joist. <br />Od nails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />9 <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer � Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or J <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* — <br />Joist <br />When joists meet over wall, provide <br />—1 3/4" minimum bearing for each. I -Joist can be offset <br />Web Stiffener Fastener Schedule <br />Joist Bearinq Location <br />Series I Depth End Intermediate <br />BCI 5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />5-8d <br />BC160s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />Use 1 Odx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />6" A 1 2' ROUND HOLE MAY 6"7=ROUNDIN <br />DO NOT CUT HOLES <br />BE CUT ANYWHERE IN LARGER THAN 1%2' <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1%" <br />8 <br />T-C'T-T' <br />1 <br />1 Z' <br />4'-3' <br />1 -S <br />1'-Z <br />1'A 1,. <br />24' <br />3-0 <br />S, 7 <br />---ARy 16'joist <br />12 <br />T-W <br />I'A" <br />1' 2- <br />1, 2" <br />1' 3' <br />T ' <br />2-4' <br />2-11 ' <br />3-7' <br />4.. <br />4-9' <br />9-4, <br />16 <br />T-C' <br />T-T' <br />1,2,. <br />1 2" <br />1' T' <br />2'-9" <br />3- ' <br />3-10" <br />4-9" <br />67" <br />6-41 <br />7-2" <br />21J <br />T-a" <br />V-1,• <br />1' 2" <br />1' Z' <br />2-7" <br />3r-0" <br />4-0" <br />4-10" <br />6'-11" <br />6-11" <br />7' 11" <br />&_1111 <br />24 <br />1'4r <br />T-1" <br />T-2' <br />1'-3" <br />2-6" <br />3-7" <br />4-9" <br />6'-10" <br />72" <br />S'-'" <br />9-6- <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1tz" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Joist hanger <br />SIMPSC <br />w/(22)- <br />NAILS 1 <br />5181 <br />THRU <br />BOLT <br />SIMPSC <br />w/(22)- <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />00 <br />FINQH GRADE <br />I —I I—i I—III—i i I— I I —I i— <br />° III —I <br />—III—III—III=III=III III —III I I I— <br />�Il�ll�lllil�l� �I�IIII �II�II�II�I illllll� <br />I-1 <br />Backer block (12" wide min.) <br />Nail with 10-1 Od nails. <br />Install tight to top flange. SLEEVE THRU STEM a <br />°. ° <br />SEE PLAN FOR °• ° . • • <br />FOUNDATION INFO ` q ' 4' ° . <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap - <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />it 0.6 X Joist <br />p , � ��depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE REINF. SEE PLAN <br />° �-x <br />a <br />I —III —I I— I <br />a ' °° IIIIIIII; III—' <br />II —I SA/C�CHAS <br />E(2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />® LOCATION OF <br />a <br />SECOND H10A <br />SIMPSON H10A ° ' a° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />�— — 4° <br />"-II1=1IIIIII <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />c — a <br />II— <br />ICI —III;, <br />1=1II-1II- <br />- - SEE FND. PLN. <br />SIZE & REINF. <br />12° BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0"— <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />/ r—PLUMBING LINE <br />z <br />A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />a° <br />4 ° <br />a 4 <br />a <br />° <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />cV <br />crr <br />CID <br />cv <br />.._ <br />�r--: o <br />_o� <br />CV t <br />N O <br />s ;3 co <br />a ca w <br />c o <br />y�•� a <br />G E <br />o <br />a <br />0 <br />P•p. <br />tiR���• <br />..jtlN <br />�. <br />St <br />%�2 <br />e <br />C-7 <br />6 <br />� <br />r"����wi�:��xtadttt�l•�i <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />W <br />a <br />v E <br />0 <br />° <br />N <br />U <br />O � o <br />�, o <br />O <br />� Lo <br />N <br />Q <br />� rNi v � `•. <br />� J <br />W <br />_J d <br />Z_ <br />_ W <br />m °c , <br />1. <br />W <br />C N '? Z <br />�'mNO <br />02Ernrn m <br />1M <br />IL Z <br />co Z Q J <br />ZN <br />OU 0. <br />IN <br />❑ <br />tee- N M <br />o o <br />z <br />z o � <br />— <br />a <br />M <br />N <br />z <br />o <br />v <br />(D <br />0 <br />cn <br />,.,, oOft <br />U 6 <br />819 <br />° 8 <br />i0 <br />N o <br />C U Y <br />¢ <br />Mild <br />N <br />�� <br />o <br />co <br />< <br />w <br />CM <br />CID�S <br />m ¢ <br />o <br />Z <br />Z <br />`_ <br />Q E <br />�� <br />Zo <br />Z" <br />i- 'd <br />¢0 <br />XU <br />�a�` <br />UY <br />�O <br />z <br />a E <br />N <br />w� <br />o <br />a❑ <br />wz <br />�w <br />s <br />Cn <br />�< <br />o� <br />"m <br />m� <br />, <br />OZF <br />z <br />� <br />�� <br /><w <br />zz <br />3 <br />zz <br />g° <br />Q <br />S <br />a <br />�w <br />W <br />w0 <br />x <br />J <br />ro <br />ro <br />ola <br />o 3 <br />.0 <br />2 N <br />> Ln <br />co <br />\ <br />ZA <br />CU <br />O <br />C:) <br />L.f') <br />o <br />J <br />r <br />N <br />Mco <br />O <br />�C <br />r <br />S <br />N <br />O <br />00 <br />� <br />Q- <br />M <br />r <br />in <br />4-1 <br />Q <br />O <br />CD N <br />LO <br />CD <br />ZD <br />Q <br />CD C) <br />M Lo <br />.co <br />Lo <br />F4 <br />c <br />O <br />( <br />r <br />E <br />M <br />N <br />o <br />z <br />z <br />M <br />E <br />N <br />r6 <br />a Co <br />E <br />U J <br />Q p <br />r <br />JOB <br />NO: 22-09484-09479 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN1 <br />PASCO COUNTY <br />