ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />MO <br />200 amp <br />150 amp <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />NEMA i <br />150 AMP/ <br />200 AMP <br />4 to lights & outlets <br />2 to appliances and GFI <br />3 to WH <br />to Range <br />to HVAC <br />150=210 <br />200=4/0 in 2" Conduit <br />— 4 Bare Cu Ground <br />#4 GROUNDING WIRE <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699, <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />KD= <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />,'3 <br />THREE-WAY SWITCH <br />6. <br />_)4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />�{ <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;O <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />FTV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />f <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />Q, 0 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />SMOKE DETECTORS <br />SMOKE DETECTORS SHALL BE IN ALL SLEEPING <br />AREAS, SHALL BE INTERCONNECTED, SHALL BE WITHIN <br />1' TO 3' OF PEAK, AND SHALL BE 3' FROM THE <br />SUPPLY OR AIR STREAM, AND EQUIPPED WITH <br />BATTERY BACK—UP. ALL SMOKE DETECTORS TO BE <br />ARC —FAULT PROTECTED. <br />FAIR HOUSING ACT REQUIREMENTS: <br />OPERABLE PARTS OF THE CONTROLS FOR LIGHT SWITCHES, ELECTRICAL <br />OUTLETS, THERMOSTATS AND OTHER ENVIROMENTAL CONTROLS MUST BE <br />LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVE THE FLOOR. <br />IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, AN OVERHANGING <br />SHELF) BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAXIMUM HEIGHT IS <br />REDUCED TO 44" FOR FORWARD APPROACH; OR 46" FOR SIDE APPROACH <br />PROVIDED THE OBSTRUCTION (FOR EAXMPLE, A KITCHEN BASE CABINET) IS <br />NOT MORE THAN 24 " IN DEPTH. OBSTRUCTIONS SHOULD NOT EXTEND MORE <br />THAN 25" FROM THE WALL BENEATH A CONTROL. <br />VERIFY P/ <br />LOCATIOt <br />BUILDER <br />Wp <br />DISC. <br />COMP. . <br />� 2't V R <br />T <br />r� <br />I <br />I <br />�PV VAR � 31t 311 <br />VVG 5� 2° <br />2° I <br />311 " <br />3'� 2 V i 3tt <br />� <br />�ITG/ T� BENT I i LAV 311 311 Oil <br />i 131t <br />T C <br />Ug <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />UNIT 1500 - ELECTRICAL PLAN <br />SCALE: 1 /4"= V-0" <br />,N <br />0 <br />crr <br />N <br />Il— <br />� <br />O <br />g := <br />® <br />' W <br />o <br />C C6 V N <br />o am x <br />,y S47'C L <br />V> .may C'-4 .� <br />US l9 <br />4 <br />2 W <br />C <br />3 �c <br />:w w <br />_E <br />�Q <br />�v <br />GV <br />CN <br />O <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />H <br />W <br />AAft <br />vE <br />`Q <br />V <br />N � N r <br />co y m <br />,01w <br />Yf <br />� r r s J <br />i <br />M <br />ll V <br />C J u- Lu <br />to LL LL 5 ' 0" <br />Z <br />0 <br />W <br />— 6 d Y <br />0,1 <br />WL <br />c6 0 <br />wo <br />o:go, O <br />W <br />to °� °. m ul <br />LL,.� <br />� M Z Q <br />M <br />N O U Q CJ <br />0 to <br />W <br />00 <br />v M � <br />Z N M <br />0 0 <br />z a4, <br />ta.- <br />U) <br />N <br />N <br />M <br />�6 <br />ch .o <br />uj <br />V <br />O <br />N <br />ty o <br />01- <br />N <br />=Nis .) <br />Z .0 U <br />oo <br />N <br />O <br />o <br />CO <br />w <br />M <br />¢ <br />zo <br />z <br />¢ <br />LL <br />L? � <br />O <br />o z <br />Z � <br />Q <br />Z p <br />oa <br />CU U <br />rCS <br />�o <br />U <br />wp <br />� U <br />O E <br />C1 <br />O�Q <br />ao <br />wo <br />JCL <br />az <br />N to <br />¢to o <br />�w <br />m 0 <br />- <br />m <br />z <br />J <br />2 <br />01. <br />¢ w <br />�z <br />to <br />z0 <br />aU <br />a) <br />SL <br />O4 <br />w <br />d z <br />mw <br />C <br />g <br />¢o <br />~ <br />az <br />G <br />10 <br />a <br />°zla <br />o 3 <br />0 <br />2 N <br />>Lr) <br />Cn <br />co <br />rn <br />m <br />O <br />\ <br />O <br />0 <br />0 <br />Ld <br />s <br />J <br />Ln <br />0 <br />o <br />O <br />Q <br />M <br />n <br />r <br />/ <br />�_ <br />Cr <br />U <br />N <br />O <br />M <br />rn <br />Q <br />CD <br />r <br />Q <br />4--+ <br />iY <br />® <br />� N <br />U-) <br />N <br />QIn <br />N <br />CV <br />M <br />O <br />U-) <br />c <br />N <br />�' ® <br />00 <br />(0 0 <br />r <br />E <br />O <br />z <br />to <br />Z <br />� M <br />E <br />N <br />y <br />v <br />`m <br />E <br />U_j <br />Q 0 <br />c <br />_j <br />JOB <br />NO: 22-09484-09479 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />- 1 ... .f. n N.. ... ...r - <br />...,u-!r.,,., -:� a ......_... ->. ",� _.. u.........-. r. ,.._: .r.. ,.... : _ ... n:,. _..... .. s _.. .. .., ..R �, .e�Is _ fia. 4•^xa,. r. ., _ � 1': -}e. .:'�r� ... ... - <br />