5TRUGTURAL NOTE5
<br />REOU I RED SAFETY C LAZ I NO IN HAZARDOUS LOCATIONS
<br />(RE: FBC 2405.2.1)
<br />2405.1 C-eneral. Individual glazed areas including glass mirrors in hazardous locations
<br />such as those indicated in 2405.2 shall pass the test requirements of GP5G 16-CFR,
<br />Part 1201 or by comparative test shall be proven to produce or least equivalent performances.
<br />Exceptions:
<br />I. Polished wire glass installed in fire doors, fire windows and view panels in fire resistant
<br />walls and hazardous locations in 2405.2.1(3) and 2405.2.1(4) shall comply with AN51 Z47.1.
<br />2. Approved plastic moterlals used as glazing In hazardous locations shall comply with AN51 Z47.1.
<br />2405.2 Hazardous Locations
<br />2405.2.1 The following shall be considered specific hazardous locations for the purpose
<br />of glazing:
<br />I. blazing in swinging doors and fixed and sliding panels of sliding
<br />(patio) door assemblies.
<br />2. Olozinci in doors and walls of enclosures for h t tubs, whirl ools,
<br />sauna ; steam rooms, bathtubs, showers qnd ot�i r such fac Iittes
<br />"hereuGh gqlazinngq i99 iosated 36 Inches (414 mnv or less,
<br />measured hohizonCaliy, from a standing or walking surface within
<br />the enclosure and where the bottom edge of the exposed glazing is
<br />less than 60 Inches (1524 mm), measured vertically, above such
<br />standing or walking surface.
<br />3. Glazing in an individual fixed or operable panel adjacent to a door
<br />where the nearest vertical ed a is within a 24-inc_h (610 mm)
<br />radius of the door Tn a closed 0osition and whose botttom e e is
<br />less than 60 inches (1524 mm) above the floor or walking sur{ace.
<br />Exception:
<br />I. 61azln in walls perpendicular to the plane of the door in a closed position In Group R3
<br />or within dwelling units in Group R2 shall be subject to 2405.2.1(4).
<br />6lazlnq In an individual fixed or operable onel, other than those
<br />4.locations described in items 2 and 3 oboJe, that meets all of the
<br />following conditions:
<br />4.1 Exposed oref of an Individual pane greater than 4 sq. ft.
<br />(0.&4.m )
<br />4.2 Bottom edge less than 15 inches (45-1 mm) above the floor.
<br />4.3 Top edge greater than 36 inches N14 mm) above the floor.
<br />4.4 One or more walking surfaces within 36 inches (a14 mm)
<br />horizontally of the plane of the glazing.
<br />5. All glazing in railings regardless of area or height above a walking
<br />surfaces Including structural baluster panels and non structural in -
<br />fills panels.
<br />6. Glazing in walls and fences enclosing indoor and outdoor swimming pools and
<br />spas where the bottom exposed edge of the glazing Is: (1) less than 60 Inches
<br />(1525 mm) above the walking surface on the pool side of the glazing, and (2)
<br />the glazing Is within 60 inches (1525 mm) horizontally of the water's edge of a
<br />swimming pool or spa. This shall apply to single glazing and all panes in
<br />multiple glazing.
<br />P=
<br />T
<br />a
<br />0
<br />� w
<br />e�
<br />u ao'
<br />r •
<br />�y
<br />a
<br />J m
<br />N
<br />u �
<br />J '
<br />v
<br />m
<br />�Y
<br />u �e •
<br />J
<br />o •
<br />m
<br />A •
<br />p C
<br />m
<br />J o.
<br />COMPONENT $ CLADD I NCB DES I C N PRESSURE
<br />(120.MPH, 3 5EG. 61.5T, 2.1/12 TO 6.4/12 PITCH, EXPOSURE B, IMPORTANCE FACTOR=1)
<br />(PSF)
<br />TRIBUT(FAREA
<br />ROOF
<br />WALL
<br />T')
<br />10
<br />14A -50.1
<br />25A -34."1
<br />20
<br />13b -45.4
<br />24.7 -32.4
<br />50
<br />11 A -34.3
<br />23.2 -24.3
<br />100
<br />10.5 -34.7
<br />22.0 -26A
<br />125
<br />10.5 -34. I
<br />21.7 -26.2
<br />NOTE5: I FOR EFFECTIVE AREA5 OR WIND 5PEED5 BETWEEN TH05E 61VEN ABOVE, THE
<br />LOAD MAY BE INTERPOLATED, OTHERWISE U5E THE LOAD ASSOCIATED WITH
<br />THE LONER EFFEGTIVE AREA.
<br />2 TABLE VALUES 5HALL BE ADJUSTED FOR HEIGHT AND EXPOSURE BY
<br />MULTIPLYING BY ADJUSTMENT GOEFFICIENT5 IN TABLE 1606.20 OF THE FLORIDA
<br />BUILDING CODE 2001.
<br />3 PLU5 AND MINUS 516N5 516NIFY PRE55URES ACTING TOWARD AND AWAY FROM
<br />THE BUILDING SURFACES.
<br />PREGAST L I NTEL
<br />SAFE C RAV I TY LOAD TABLE
<br />LENC TH
<br />SAFE LOAD - POUNDS PER LINEAR FOOT
<br />UNFILLED
<br />FILLED
<br />2'-10" (34") PRECAST
<br />2302
<br />6,861
<br />3'-6" (42") PRECAST
<br />2302
<br />6,039
<br />4'-0" (48") PRECAST
<br />2,029
<br />4,657
<br />4'-6" (54") PRECAST
<br />1,624
<br />3,662
<br />5'-4" 64" PRECAST
<br />1,184
<br />3,241
<br />5'-10"(64") PRECAST
<br />972
<br />2,718
<br />6'-6" (78") PRECAST
<br />937
<br />2,332
<br />7'-6" (90") PRECAST
<br />767
<br />2,040
<br />9'-4" (112") PRECAST
<br />573
<br />1,529
<br />10'-6" 126" PRECAST
<br />456
<br />1,392
<br />11'-4" (136") PRECAST
<br />445
<br />1,234
<br />12'-0" (144") PRECAST
<br />414
<br />1,140
<br />13'-4" (160") .PRECAST
<br />362
<br />1,073
<br />14'-0" (168") .PRECAST
<br />338
<br />1,003
<br />14'-8" 176" PRE STRESSED
<br />N.R.
<br />1,370
<br />15'-4" 184" PRE STRESSED
<br />N.R.
<br />1,203
<br />17'-4" (206") PRE STRESSED
<br />N.R.
<br />950
<br />19'-4" (232") PRE STRESSED
<br />N.R.
<br />750
<br />21'-4" 252" PRE STRESSED
<br />N.R.
<br />610
<br />22'-0" 264") PRE STRESSED
<br />N.R.
<br />570
<br />24'-0" (288") PRE STRESSED
<br />N.R.
<br />470
<br />- SAFE LOAD VALUES ARE BASED ON MANUFACTURER'S CALCULATIONS.
<br />- PRECAST LINTELS MAY BE SUPPLIED ONLY BY APPROVED
<br />PRECAST MANUFACTURERS. (SEE SECT 4.3)
<br />- FILLED LOAD VALUES ASSUME A MINIMUM 8" CONCRETE FILLED KNOCK -OUT BLOCK ABOVE
<br />THE PRECAST LINTEL AND ONE #5 BAR IN THE LINTEL.
<br />GLASS BLOCK INSTALLATION PERFORMED IN ACCORDANCE WITH FBC
<br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY
<br />AT LEAST 2 HOURS BEFORE PLACING MORTAR.
<br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP
<br />EXTENDS TO SILL.
<br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL.
<br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS
<br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE
<br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE
<br />A RUBBER CRUTCH TiP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT
<br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS
<br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER
<br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT.
<br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS
<br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING
<br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL
<br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS.
<br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE
<br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING, INSTALL
<br />REINFORCING AS FOLLOWS:
<br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW.
<br />* PRESS PANEL REINFORCING INTO PLACE.
<br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL
<br />SMOOTH. DO NO FURROW.
<br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT
<br />FURROW. MAINTAIN UNIFORM JOINT WIDTH.
<br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST
<br />REMAIN FREE OF MORTAR.
<br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STiLL PLASTIC AND BEFORE FINAL SET. AT THIS
<br />TiME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE
<br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY.
<br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE
<br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.)
<br />W,
<br />m
<br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN
<br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING.
<br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE
<br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS.
<br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING.
<br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR
<br />INSTALLATION OF GLASS BLOCK.
<br />20 _ga__ PANEL
<br />%
<br />A�F�
<br />9 ca. PANEL
<br />REINFORCING
<br />(EVERY
<br />OTHER
<br />STRIP
<br />1/4' EXPANSION
<br />BOLT (2 PER
<br />ANCHOR)
<br />STRIP
<br />6' MIN.
<br />LAP SPLICE
<br />W/ REIWO2CI G
<br />6' MIN. PANEL
<br />LAP SPLICE
<br />NOTEe
<br />SEE GLASS BLOCK
<br />INSTALLATION NOTES.
<br />GLASS 5LOCK DETAIL
<br />* (110mph FASTEST WIND= 130MPH, 3 SEC. GUST. FBC TABLE 1606.1.6.1)
<br />ROOF DIAPHRAGM NAILING SCHEDULE
<br />RIDGF I INF
<br />A. +
<br />+ + + + + + + + +a
<br />+ + + + + + + + + + + + + +
<br />+
<br />+
<br />+ + + + + + + + O
<br />+ + + + + + + + + + + + . +
<br />+ +
<br />A.
<br />+ + + + + + + + co
<br />+ + + + + + + + + + + + + +
<br />+ +
<br />+ +
<br />+
<br />+ + +
<br />+ +
<br />+ +
<br />+ + +
<br />+ + +
<br />+ +
<br />+
<br />+ +
<br />+
<br />+++
<br />+
<br />+ + A
<br />+ + A. + /++
<br />+
<br />+ + + + + + + + + +
<br />:+Ss
<br />+ +
<br />L+
<br />+ +
<br />+ + + + + +
<br />+
<br />+
<br />+ +
<br />+ + + + + + + + + +
<br />+ + + + ++
<br />+ +
<br />M
<br />`--RIDGE LINE
<br />120 MPH 3 SECOND GUST EXPOSURE "B" WIND ZONE I 120 MPH 3 SECOND GUST EXPOSURE "B" WIND 2
<br />8d COMMON NAILS ® 6' O.C. &
<br />+ + 4" O.C. 0 GABLE END WALL OR GABLE TRUSS
<br />+ + .131OX2 1/2' LONG GUNNAIL 0 4' O.C.
<br />.12000" LONG GUNNAIL 0 4' O.C.
<br />.11302" LONG GUNNAIL 0 3" O.C.
<br />.099OX2 1/4' LONG GUNNAIL 0 3' O.C.
<br />8d COMMON NAILS 0 6' O.C. EDGES &
<br />8d COMMON NAILS 012" O.C. INTERMEDIATE
<br />.131OX2 1/2" LONG GUNNAIL ® 4" O.C.
<br />EDGES & 8" O.C. INTERMEDIATE
<br />.12003" LONG GUNNAIL 0 4" O.C.
<br />EDGES & 8" O.C. INTERMEDIATE
<br />.1130X2" LONG GUNNAIL 0 3' O.C. EDGES
<br />(STAGGERED) & 8' O.C. INTERMEDIATE
<br />NOTE: 1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. 099vu 1/4' LONG UU14NPJL ® 3. O.C.
<br />2 EDGES & 6" O.C. INTERMEDIATE
<br />END JOINTS OF THE ROOF SHEATHING SHALL
<br />BE STAGGERED AND OCCUR OVER FRAMING MEMBER.
<br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS
<br />FIR OR BETTER. IF ROOF FRAMING CONSISTS OF A LESSER (MADE OF LUMBER, CONTRACTOR MUST
<br />CONTACT DANSCO ENGINEERING, P.A. FOR ALTERNATE FOR NAILING PATTERN.
<br />❑ SAMUEL A. GREEN5ERG, P.E. 034245
<br />❑ THUY H. HUYNH, P.E. %0122
<br />❑ IWIN J. 5ENSON, P.E. 049i55
<br />❑ AL 1 A554S HAKIM, P.E. 056186
<br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THE
<br />STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WiTH THE
<br />FLORIDA BUILDING CODE, SECTION 1606 FOR 120 MPH 3 SECOND
<br />GUST, EXPOSURE 'B' WIND ZONE (2001 EDITION).
<br />TWIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE
<br />DATE IT IS SIGNED AND SEALED.
<br />SKID AND SEALED FOR TI4E STRUCTURAL PORTION OF THIS
<br />DRAWING ONLY.
<br />DAN5GO
<br />AoCREATED 01-02-02 D� ���.4 T--'A'
<br />PA. SOX 3400 - APOLLO SEAC 4 - FLORIDA - 33512
<br />12 0 MPH FV" - (813) 648 0*6 FAX - (813) 648 96W
<br />4bi0 © �7 ONTHISPROJECT. DESIGNS
<br />ARE
<br />RREPRTHE JOINT
<br />ON PROPERTY HORIIED USE ENGINEERING,IS P.A. AND THE
<br />3 SEC. GUST
<br />SEAL LENNAR HOMES
<br />SCALE NOTED RAU�I B.V.
<br />NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION TAMPA DIVISION
<br />BEGINS. DANSCO ENGINEERING P.A. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PATE V2/� rN:/BLOCKS/STD 2001
<br />PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS'SHOP DRAWINGS, �+ /� �+ t /� �+
<br />DRAWINGS MUST BE BROUGHT RTOBTHEIATTENTION NG DOF DANSCO ENGINEERING P.AS, AND THESE SIGNED AND . PRIOR TO ALED STRI,tCTUR�4L NOTES 4 I A15LES
<br />THE COMMENCEMENT OF CONSTRUCTION.
<br />DE J05 NO. PM - 5021 W2
<br />.im