STRUGTURAL NOTES <br />SPEGIFIGATIONS <br />I. I. GONSTRUGTION <br />1. 1, 1. AGI 310-02 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />I. I. 2. AGI 530/A5GE 5/TM5 402-qg d AGI 530, I/A56E 6/TM5 602-qcl <br />SPECIFICATIONS FOR MASONRY STRUCTURES. <br />I. 1. 3. A5TM G270-q2, G476-01, AND GqO-qO SPECIFICATIONS FOR MASONRY STRUCTURES <br />I. I. 4. NATIONAL DESIGN SPECIFICATIONS (ND5) FOR WOOD CONSTRUCTION, 2001 EDITION, AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />FLORIDA BUILDING CODE (FBG), 2001 EDITION <br />I. I. 6. "MANUAL OF STEEL GONSTRUCTION, ALLOWABLE 5TRE55 DESIGN", BY THE AMERICAN <br />INSTITUTE OF STEEL CONSTRUCTION, (A15C) cTTH EDITION. <br />I. I. 7. °DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE <br />TRU55 PLATE INSTITUTE (TPI) Igg5 EDITION. <br />DES I ON : <br />I. 2. I. AGI 315-02 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />I. 2. 2. AGI 530/A5GE 5/TMS 402-qq r£ AGI 530, I/A5GE 6/TM5 602-qq <br />SPECIFICATIONS FOR MASONRY STRUCTURES. <br />I. 2. 3. ASTM G270-q2, G476-41, AND GqO-q0 SPECIFICATIONS FOR MASONRY STRUCTURES <br />I. 2. 4. NATIONAL DESIGN SPECIFICATIONS (NIPS) FOR WOOD CONSTRUCTION, 2001 EDITION, AND ALL <br />A6GOMPANYIN6 SUPPLEMENTS. <br />I. 2. 5. PLYWOOD DE516N SPECIFICATIONS (APA) <br />1. 2. 6. FLORIDA BUILDING CODE (FBG), 2001 EDITION <br />SHOP <br />DRAW I NC 5 : <br />THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS <br />DURING THE PREPARATION OF SHOP DRAWIN65 WITHOUT WRITTEN APPROVAL FROM <br />THE ENGINEER OF RECORD. <br />I. 3. 2. <br />ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO <br />THE COMMENCEMENT OF CONSTRUCTION. <br />I. 3. 3. <br />ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A <br />FLA. REG. PE. AND SHALL INCLUDE : DRAWINGS AND CALCULATIONS, REACTIONS AND <br />BEARING POINTS, BRAGING REQUIREMENTS, AND CONNECTIONS TO <br />SUPPORTING TRUSS MEMBERS. <br />2. DESIGN LOADS <br />2. ! . DEAD <br />LOADS <br />2. 1. I. <br />UNIT WEIGHT OF SOIL, COMPACTED : 120 PGF <br />2. 1. 2. <br />UNIT WEIGHT OF REINFORCED CONCRETE 150 PGF <br />2. 1. 3. <br />UNIT WEIGHT OF 0" G.M.U. BLOCK : 40 P517 <br />2. 1. 4. <br />15T FLOOR 5UPERIMP05ED LOAD 20 P5F <br />2. 1. 5. <br />UNIT WEIGHT OF 2x4 PARTITION HALLS: II PSF <br />2. I. 6. <br />UNIT WEIGHT OF 2x6 BEARING WALLS : 12 PSF <br />2. 1. 7. <br />BALCONIES $ DECKS : 15 PSF <br />2. 1. 0. <br />TILE ROOF <br />TOP CHORD 15 PSF <br />BOTTOM CHORD 10 P5F <br />2. I. q. <br />SHINGLE ROOF <br />TOP CHORD 7 P5F <br />BOTTOM CHORD : 10 PSF <br />2. I. 10. <br />FLOOR TRUSSES 15 <br />2. 2, LIVE LOADS : <br />2. 2. I. <br />SIDEWALK AND DRIVEWAY LOAD: <br />200 P5F <br />2. 2. 2. <br />GARAGE LOADS: <br />50 P5F <br />2.2.3. <br />CORRIDORS AND BATHROOMS <br />00 P5F <br />2.2.4. <br />PARTITIONED ROOMS: <br />40 P5F <br />2. 2. 5. <br />BALCONY AND DECKS : <br />40 P5F <br />2. 2. 6. <br />STAIRWAYS AND LANDINGS : <br />40 P5F <br />2. 2. 7. <br />ROOF: <br />20 PSF <br />2. 2. 5. <br />FLOOR TRUSS <br />TOP CHORD MINIMUM : <br />40 P5F <br />2. 2. q. <br />ROOF TRUSS <br />TOP CHORD MINIMUM <br />20 PSF <br />2. 3. RAILINO LOADS : <br />2. 3. I. ALL RAILING AND GUARD RAIL 5YSTEM'5 ARE TO BE DESIGNED TO WITHSTAND A <br />CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY <br />DIRECTION ON THE RAILING. <br />2. 3. 2. ALL RAILING AND GUARD RAIL 5Y5TEM'5 ARE TO BE DE516NEP TO WITHSTAND A <br />HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD <br />OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL <br />2.5.5. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED <br />HORIZONTAL LOAD APPLIED ON 150. FT. AT ANY POINT IN THE SYSTEM. <br />2. 3. 4. 2.3.1., 2.3.2 $ 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH <br />SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. <br />2. 4. WIND LOADS : <br />2. 4. I. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. 1606 OF THE <br />FBG, 2001 EDITION, AND CONDUCTED BASED ON A 120 MPH, 3 SECOND GUST, <br />EXPOSURE "B", IMPORTANCE FACTOR "I" = I.O. ENCLOSED BUILDING. <br />2. 4. 2. NET UPLIFT DEAD LOADS - 10 PSF SHINGLE, 15 P5F TILE <br />2. 5• DEFLECTIONS : <br />2.6. I. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO 1/360 TIMES THE SPAN FOR LIVE LOADS <br />AND 1/240 TIMES THE SPAN FOR TOTAL LOAD. <br />STRUGTURAL NOTES <br />5. DESIGN METHOD <br />3. 1. LOAD FACTOR DE51ON <br />3. I. I. THE LOAD FACTOR DESIGN METHOD WA5 USED TO DE516N : <br />GA5T-IN-PLACE CONCRETE SLABS AND FOOTINGS <br />3. 2. SERVICE LOAD DES I ON : <br />3. 2. I. THE SERVICE LOAD DESIGN METHOD HAS USED TO DESIGN <br />MASONRY WALL5 AND LINTELS <br />INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING <br />STAIRS AND FLOOR FRAMING <br />ROOF FRAMING, SHEATHING AND UPLIFT <br />3 3 LOAD GOMBINATIONS FOR LFRD DESIGNS <br />3. 3. I. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR <br />TOTAL DL + FLOOR LL + ROOF LL <br />TOTAL DL + FLOOR LL + WL <br />TOTAL DL + WL <br />3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RE515T THE WORST LOAD <br />COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. <br />BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. <br />3 4, DESIGN A55UMPTIONS : <br />3. 4. I. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLE55 <br />5HOWN OTHERWISE IN THE DESIGN PLANS. <br />4. MATERIALS <br />4.1. RE I NFORG I NC-C STEEL : <br />4. I. I. <br />REINFORCING STEEL SHALL BE A5TM A615-cI4 GRADE 40, f'y = 40 K5I <br />4. 1. 2. <br />LAP SPLICE SHALL BE AS FOLLOW5: #5 BAR 25", #4 BAR 20", #3 BAR 15". <br />4. I. 3. <br />ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE <br />GENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION 15 5HBWN TO THE <br />FACE OF THE CONCRETE. <br />4. I. 4. <br />REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. <br />4. I. 5. <br />REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED <br />YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF <br />RECORD. <br />4. I. 6. <br />DE51ON COVER REQUIREMENTS <br />G-I-P CONCRETE FORMED AGAINST EARTH 3" <br />6-1-P CONCRETE EXPOSED TO EXTERIOR: 2" <br />G-I-P CONCRETE NOT EXP05ED : 1 1/2" <br />GROUT FILLED MASONRY : 3/4" <br />PRE 5TRF55ED CONCRETE LINTELS (ADD. REBAR IN) 1 1/2" <br />PRE GAST GROUT FILLED LINTELS (ADD. REBAR IN) 1 1/2" <br />4. 1. 7. <br />WELDED WIRE FABRIC (WWF): ASTM AI05-clOa. <br />4. I. 5. <br />DETAIL REINFORCEMENT IN AGGORDANGE WITH AGI 315-LATE5T EDITION. <br />4. 2. CONCRETE <br />4. 2. I. <br />CONCRETE TYPE <br />MIN. 20 DAY <br />DESIGN (f'c) <br />MODULES OF <br />ELASTICITY <br />DE51ON (E) <br />G-I-P CONCRETE (NORMAL WEIGHT) <br />2,500 P51 <br />2,b50 Ksi <br />G-I-P GROUT <br />2,500 Psi <br />2,050 Ks[ <br />PRE GAST CONCRETE LINTELS <br />3,000 P51 <br />3,122 Ksl <br />PRE 5TRE55ED CONCRETE LINTELS <br />5,000 P5I <br />4,030 K51 <br />4.2.2. CONCRETE SHALL CONSIST OF I" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP <br />BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL <br />CRITERIA. <br />4.2.3. GROUT SHALL GON515T OF PEA ROCK (3/5" MAXIMUM AGGREGATE) CONCRETE MIX <br />WITH SLUMP BETWEEN 0" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR <br />ADDITIONAL CRITERIA. <br />4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED <br />4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND GURING SHALL BE GONDUCTED IN <br />ACCORDANCE WITH THE 5PECIFIGATION5 A5 STATED. <br />4. 2. 6. EARTH SUPPORTED 5LAB5 (EXGLUDING EXTERIOR WALKWAYS 4 DRIVEWAYS) <br />3 1/2" MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF <br />MID -DEPTH OF SLAB. FIBER MESH MAY BE USED I.L.O. WWF ® GONTRAGTOR5 DISCRETION. <br />4.2.1. CONCRETE PLACEMENT PRACTICES `✓HALL BE IN ACCORDANCE W/ ALL <br />AGI- MCP Iggq STANDARDS. <br />4. 3. CONCRETE MA50NRY : <br />4. 3. I. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED ® 5'-0" O.G. MAX, ® BOTH 51DE5 <br />OF OPENINGS 6'-0" WIDE OR MORE, @ THE HIGH SIDE OF ALL MASONRY WALL <br />STEPS, a ® ALL CHANGES IN DIRECTION OF THE MA50NRY WALLS. <br />4. 3. 2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE A51-M G90-CIO, TYPE II <br />NON -MOISTURE CONTROLLED. <br />4. 3. 3. ALL CELLS 4 CAVITIES BELOW GRADE WILL BE FILLED W/ GONGRETE IN ALL <br />STEM WALLS. <br />4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 P51 <br />MINIMUM. <br />4. 3. 5. METHOD OF CONCRETE MASONRY PLACEMENT AND GON5TTRUCTION SHALL BE <br />CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. <br />4.3.6. MORTAR SHALL BE TYPE "5" FOR ALL MASONRY CONSTRUCTION. <br />4. 3. 7. LINTELS SUPPLIED BY APPROVED MANUFACTURER: <br />1) FEGP/GAST-GRETE CORPORATION <br />2) POWER GONGRETE <br />3) ALLIED PRECAST <br />4) LOTT <br />5) MARION MASONRY <br />6) WIEKKA <br />STRUGTURAL NOTES <br />4.4. STRUCTURAL LUMBER : <br />4. 4. I.1. INTERIOR LOAD BEARING WALLS S.P.F., fb = 675 P51, E = 1200 K51 <br />ALL EXTERIOR FRAMING S.P.F., fb = 675 PSI, E = 1200 K51 <br />ALL FRAME WALLS TO BE CONSTRUCTED USING S.P.F. , <br />STUD QUALITY OR BETTER <br />4. 4. 2. ALL PLYWOOD USED FOR EXTERIOR APPLICATION5 <br />SHALL BE APA RATED SHEATHING EXP I U.N.O. <br />4.4.3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND <br />SHEAR WALLS SHALL BE APA RATED 5HEATHING EXP I U.N.O. <br />4.4.4. IF 05B BOARD 15 TO BE USED IN PLACE OF PLYWOOD IS TO HAVE 51MILAR OR <br />GREATER SECTION PROPERTIES. <br />4. 4. 5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN <br />GONTAGT WITH CONCRETE 15 TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />4.4.6. WHEN PRE ENGINEERED TRUSSES ARE GALLED FOR ON THE PLANS THE <br />MANUFACTURER 15 TO SUBMIT SHOP DRAWIN65 TO THE ENGINEER OF RECORD. <br />4. 4. 7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACGORDANCE WITH THE "DESIGN <br />5PECIF16ATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE <br />AN51/TPI I-Igg5, HIB-ql AND 05T-00. <br />4. 4, 0, UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH GONGRETE. SEAT PLATES <br />SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. <br />4. 4. q. ALL EXTERIOR FRAME WALL5 SHALL HAVE 7/8" 5T000O FIN15H PER A5TM G. g26. <br />APPLY 3 LAYERS W/ THICKNESS OF 7/0" OVER METAL LATH. FIRST 2 LAYERS 3/0" THICK. <br />EACH, AND 3RD LAYER 1/0" THICK. <br />4.5. FASTENERS AND TIE DOWNS : <br />4. 5. I. <br />FASTENERS AND TIE DOWN5 SHALL GONSI5T OF BUT ARE NOT LIMITED TO <br />SHAPES, ANGLES, CHANNELS: A5TM A36-36M q4 Fy = 36 Ksi <br />ROUND METAL PIPE : A5TM A53-14, GRADE B Fy = 35 Ksi <br />SQUARE METAL TUBING : A5TM A500-cK GRADE B Fy = 4ro"I <br />HIGH STRENGTH BOLTS : ASTM A325-q4 <br />MACHINE BOLTS : GALVANIZED ASTM A307-q4 <br />4. 5. 2. <br />SHEET METAL ACCESSORIES SHALL CONFORM TO : Fyy = 33K51WITH bg0 <br />GALVANIZED COATING IN ACCORDANCE WITH A5TM A525-07. <br />4. 5. 3. <br />NAILS SHALL CONSIST OF : COMMON WIRE NAILS WITH MINIMUM DIAMETER AS <br />FOLLOWS: Bd = 0.113% IOd = 0.128", 12d = 0.125", I6d = 0.135". <br />4.5.4. <br />ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO RECEIVE AN ANTI-GORRO51VE COATING BY MANUFACTURER <br />PRIOR TO INSTALLATION. <br />4. 5. 5. <br />ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY GALLED <br />FOR IN THE PLANS ARE A MINIMUM. <br />4. 5. 6. <br />ALL FASTENER TIE DOWN5, BEAM HANGERS, J015T HANGERS, AND FLOOR TRU55 <br />STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND <br />5PEGIFIGATIONS. <br />4. 5. 7. <br />CONCRETE EMBEDDED 'JBOLT5 USED FOR UPLIFT ARE TO BE WET SET PRIOR TO <br />INITIAL SET OF THE CONCRETE, SPACING AND AL16NMENT ARE TO BE IN ACCORDANCE <br />WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. <br />4.5.5. <br />CONCRETE EMBEDDED TIE DOWNS USED FOR TRU55 AND WALL UPLIFT ARE TO BE <br />PLACED AROUND EMBEDDED REINFORCING PRIOR TO PLACING GROUT. <br />4. 6. MICRO <br />-LAM LUMBER: <br />4. 6. I. <br />MICRO -LAM STRESS GRADE5 SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: <br />E = 2,000,000 P51 <br />Fb = 2,950 PSI <br />Ft = 1050 P51 <br />Fc = 500 P51 (PERPENDICULAR) <br />Fc = 2,700 (PARALLEL) <br />Fv = 205 P51 <br />4.7. STEEL: <br />4.7. I. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED <br />STEEL ERECTOR. <br />4. 7. 2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.5.G. <br />"SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL <br />STEEL FOR BUILDINGS". <br />4. 7. 3. STRUCTURAL STEEL: ASTM A36-361-1 q4. <br />4. 7. 4. STEEL TUBING: A5TM A500-q4, GRADE B. <br />4.1.5. WELDED CONNECTIONS: E10XX ELECTRODES, MINIMUM 51ZE FILLET WELDS 3/16", AW5 <br />CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. <br />4. 7. 6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER <br />PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE <br />THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. <br />4. 7. 7. THE STEEL FRAME 15 "NON -SELF SUPPORTING% ADEQUATE TEMPORARY SUPPORT <br />SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR <br />ELEMENTS ARE IN PLACE. <br />STRUGTURAL NOTES <br />4. 8. 501L: <br />4. 8. I. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. <br />4. b. 2. ALL SOIL 15 TO BE GLEAN d POISONED FOR TERMITES PER FBG 2001 SECTIONS <br />104.2b, 104.23, 1403.1.6, 1503.4.4, 1016, IG16.-1.5, 2303.1.4, d 2304. <br />TERMITE PROTECTION - <br />PLANS MUST SPECIFY TYPE OF TERMITE TREATMENT <br />• Soil Chemical Barrier Method <br />• Other treatment - Must specify proposed method and submit documentation, which <br />substantiates the proposed method, Is an approved termite protection system or method. <br />IF CHEMICAL 501 L TERMITE TREATMENT 15 USED <br />1. FBG 104.2.6 - "A permanent sign which Identifies the termite treatment provider <br />and need for re -inspection and treatment contract renewal shall be provided. <br />The sign shall be posted near the water heater or electric panel" <br />2. FBG 1505.4.4 - Condensate and roof downspouts shall discharge at least <br />1'-0" away from the building side walls. <br />3. FBG 1505.4.4 - Irrigotlon/sprinkler 5 stems Including all risers and <br />spray heads shall not be Installed within 1'-0" of the building side wall. <br />4. FBG 1403.1.E - To provide for inspection for termite Infestation, between <br />wall covering and final earth grade shall not be less than 6 Inches. <br />Exception: Paint or decorative cementitlou5 finish less than 5/0" <br />thick adhered directly to the foundation wall. <br />5. FBG 1016.1.1 -- Initial treatment shall be done after all excavation <br />and backfill is complete. <br />6. FBG 016.1.2 - Soil disturbed after the initial treatment shall be retreated <br />including spaces boxed or formed. <br />7. FBG 1016.1.3 - Boxed areas in concrete floors for subsequent installation of traps, <br />etc., shall be made with permanent metal or plastic forms. Permanent forms must be <br />of a size and depth that will eliminate the disturbance of soil after the initial treatment. <br />b. FBG 1016.1.4 - Minimum 6 mil vapor retarder must be installed to protect against <br />rainfall dilution. If rainfall occurs before vapor retarder placement, <br />retreatment 15 required. <br />g. FBG 1016.1.5 - Concrete overpour and mortar along the foundation perimeter <br />must be removed before exterior soil treatment. <br />10. FBG 1816.1.6 - Soil treatment must be applied under all exterior concrete <br />or grade within 1'-0" of the structure 51dewa115. <br />11. FBG 1516.1.E - An exterior vertical chemical barrier must be installed after <br />construction is complete, including landscaping and irrigation. Any soil disturbed <br />after the vertical barrier is applied, shall be retreated, <br />12. FBG 1016.1.7 - All buildings are required to have pre -construction treatment. <br />13. FBG I016.1.7 - A certificate of compliance must be issued to the building department <br />byyLa licensed pest control company before a certificate of occupancy will be Issued. <br />certificate of compliance shall state: "The building has received a complete <br />treatment for the prevention of subterranean termites. The treatment 15 in <br />accordance with the rules and laws of the Florida Department of Agriculture <br />and Consumer Services". <br />14. FBG 2305.1.5 - After all work Is completed, loose wood and fill must be removed <br />from below and within I'-0" of the building. This includes all grade stakes, <br />tub trap boxes, forms, shoring or other cellulose containing material. <br />15. FBG 2305.1.4 - No wood, vegetation, stumps, cardboard, trash, etc., <br />shall be buried within 15'-0" of any building or proposed building. <br />4. 5. 3. SOIL 15 TO BE GOMPACTED TO q5% MODIFIED PROCTOR AS DEFINED BY <br />A5TM D 1557-ql <br />ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS <br />AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE (CCA-C) <br />WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL <br />CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES <br />HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE <br />TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT 15 <br />THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD <br />TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST <br />CORROSION, FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-5 REQUIRE <br />HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM <br />BORATE (SBX) DOES NOT. <br />A1RE\ASED 08-15-03 <br />AoCREATED 01-02-02 <br />120 MPH <br />3 SEC. GUST <br />❑ SAMUEL A. GREENBERG, P.E. *34245 <br />❑ THUY W. HUYNH, P.E. i11ro0122 <br />❑ IRWIN J. BENSON, P.E. o49158 <br />DAL ABBAS HAKIM, P.E. *56186 <br />TO THE BEST OF THE ET SHMR'S KNOUL.EDGE AND BELIEF, TW <br />STRUCTIRAL PLANS AND SPECIFICATIONS COMPLY WITH THE <br />FLORIDA BUILDING CODE, SECTION 160E FOR 120 MPH 3 SECOND <br />GUST, EXPOSURE W WIND ZONE (2001 EDITION). <br />THIS DRAWING AND DESIGN 16 VALID FOR 12 MONTHS AFTER THE <br />DATE IT 18 SIGNED AND SEALED. <br />SKIED AND SEALED FOR THE STRUCTURAL PORTION OF THIS <br />DRAWNG ONLY. <br />T- - - - - - -- - --- -- ' -- -- - - <br />7i %(' ,.:1• F r.Y Lw� b;: <br />a <br />• r . -r �,T-r---�. '.� _�-•T': r'_---__- �. <br />1 t •R. r b. <br />