VENTED SOFFIT 58 SQ. FT. <br />ATTIC VENTILATION CALCULATIONS - B <br />ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED <br />1/150 Rule Ridge <br />(No Upper Ventilators 1/300 Rule Vent Amt Off Ridge <br />Req.) (Must Provide Upper Ventilators) (Ft) Amt. <br />ATTIC <br />SPACE <br />SQ. IN. of <br />ventilation <br />required <br />SQ. FT. <br />of vented <br />soffit <br />needed <br />0 <br />Ventilation <br />Provided <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />El <br />(See ev ) <br />required <br />soffit <br />so <br />b upper <br />y <br />needed <br />ventilators <br />Main 21.00000 2.000000 <br />Floor 2377 2282 326 1141 81 570 0 591.0 <br />(Zone 1) 315.0 276.0 <br />"NOTE" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 5th ED. RESIDENTIAL. <br />VENTED SOFFIT LEGEND <br />IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED <br />AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF <br />LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. <br />VENTED SOFFIT <br />I:•:: <br />VENTED SOFFIT <br />I'�•' <br />19 SQ. FT. <br />I' <br />VENTED SOFFIT- <br />:a <br />46 SQ. FT. <br />I•' <br />..................: <br />........ ..........................: :.tip ................... 5:12SLOFF� <br />. I . . . . . . . . . . . . . . . . . . <br />......... VENTED SOFFIT �'• <br />21 SQ. FT. j•: <br />�. <br />LL GE <br />• <br />:12 SLOPE Cr 14'-0' RIDGE VENT <br />a, <br />VENTED SOFFIT <br />ZONE-1 ti% 24 SQ. FT. <br />� :Ti <br />ATTIC SPACE <br />_____ <br />T-0' RIDGE VENT <br />23 /% /% SQ. FT.::::::::::::::::::::::::::::::::::RIDGE <br />5:12SLOP �•': <br />a �•�• O <br />" <br />. �•• In <br />5:12 SLOP E♦ <br />CP <br />VENTED SOFFIT 67 SQ. FT. <br />ROOF PLAN <br />SCALE: %4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water- resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />"If not enough vented soffit is provided due to fire protection, the contractor shall use the, <br />following approved vents: <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />-Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed <br />0V <br />Z M <br />— o <br />z� <br />z� <br />Q <br />CL <br />U, z <br />V) 0 <br />cn <br />4-J w <br />O <br />L <br />o <br />o <br />Vi <br />U <br />0 <br />m � <br />E <br />' — 8 <br />�M V)w c <br />CU Cl) <br />m v N <br />O o0 <br />w <br />ILL. 00 <br />0 m <br />Y � <br />C <br />0 <br />Ln a C:)4 <br />rn Q o <br />A <br />I <br />N ( L. . Il t' <br />�� <br />t <br />s <br />r <br />1 1 14 <br />Lr-• <br />Z <br />WK �-e <br />I.— <br />-A <br />- <br />s Qi:, <br />Pin <br />WQ �,;$y1 r e <br />> <br />N lieJrl <br />O U <br />�`� <br />��` <br />❑ ❑ ❑ <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />Z rJ <br />O0-4 �t� <br />> O <br />M <br />Q -0 <br />z <br />0 <br />QJ U <br />CL �•. <br />a U CL 0 <br />z ra <br />WJ 110 <br />J <br />UocGZ} <br />W - <br />z as <br />ui <br />UZ0 <br />zwZM <br />F�2z <br />1 w � J <br />1 d 2 � <br />o°0�z0 <br />OZ <br />zz <br />0 <br />'� <br />0 <br />z <br />M <br />° <br />> <br />0 <br />Z <br />V) <br />— <br />CL <br />0- <br />0 O <br />ILLasc0 <br />Rz <br />o <br />pis <br />N <br />$,0 <br />w p <br />QFL]wo�C <br />Z <br />W <br />N <br />In <br />Y o <br />� � Ce <br />J <br />ri <br />lJ.l <br />zw <br />vl Q~ z <br />Y <br />z <br />dN' <br />,--iZ <br />Z <br />L <br />� <br />Lu <br />o <br />zo <br />Ln <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: FFLORES <br />VERSION NO. 10 <br />SHEET NO. <br />5.0 <br />