Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
60 <br />4 <br />F- <br />HEEL_HEIG_H_T <br />HEEL HEIGHT <br />---------------------- <br />T.O.P. - — — — <br />HDR.HGT <br />- — — — — — — — — — — — — — — — — — — — — — — <br />TEXTURED <br />CEMENTITIOUS <br />FINISH OVER <br />SHEATHING <br />(TYP. ) <br />Isms ado®o®o��c <br />0SMOOTH <br />TEXTCRED <br />• t. r, <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />1" x 10" SMOOTH <br />--- ----------------------- <br />2nd FIN. FLR. ________________ __________ __TEXTURED <br />------- <br />HEAD/BAND <br />T.O.M.— — — — — — — CJ / WEEP CJ / WEEP <br />} <br />HDR HGT. _ — — <br />TEXTURED 2"TYP. <br />CEMENTITIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />F_FL.----------L-----------------------J--- <br />O ICI !C1Cl D"°°�°D <br />FRONT ELEVATION - A <br />SCALE: 1 /4"=1 r-0" <br />ti00 <br />00 <br />-c6o <br />LEFT ELEVATION - A <br />E: 1 /4"=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion or <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or comice vents. <br />"CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN"" <br />(Values to be verged with Manufacturer Specifications) <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SO. FT. <br />'If not enough vented soffit is provided due to fire protection, the contractor shall use the <br />following approved vents: <br />• LOMANCO DECK -MR (Shingle Roof) - g SO. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft- Soffit Needed) x 7 = (Sq. In. Needed)19 = Linear Ft. or Deck -Air Needed) <br />C9 <br />z <br />Z <br />a13 <br />cn U <br />Cl <br />a) <br />N <br />'N w <br />(Z M <br />•U <br />— — <br />w <br />c/i = <br />L <br />U <br />mo <br />LJJ <br />'® ~ <br />N M <br />�W� <br />U <br />¢ rn <br />LL� <br />U <br />�i d <br />D. <br />NN C <br />v <br />„+ <br />N N <br />ak <br />U`1 <br />Z_ z <br />r 4 e, <br />W <br />Z V a� <br />U) Fe <br />VfE a <br />�Z <br />W � <br />����ettt tIItIRrNt1�� o <br />1b <br />c� <br />• � �O S <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />W <br />�a <br />.�I Q <br />H <br />a <br />0 <br />z <br />Og <br />a <br />U <br />J <br />A <br />W <br />N <br />g <br />JLU <br />(� <br />zO <br />F- <br />LUz <br />'a <br />3 <br />1� <br />> <br />M <br />U <br />tin <br />M <br />< <br />z <br />jig <br />ign <br />o g <br />0LL <br />W e <br />f� <br />Ln <br />Q <br />Z <br />r14 <br />J <br />T -t <br />LLI <br />Z <br />LLJ <br />Z <br />to Z <br />~ a te <br />�g <br />m <br />Z <br />tj <br />= <br />O <br />oo <br />.-11 <br />g <br />0- <br />1 to <br />8 <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAMES <br />VERSION NO. 3ol <br />SHEET NO. <br />3.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.