a <br />it <br />c <br />c <br />rn <br />00 <br />8 <br />C4 <br />N <br />02 <br />00 <br />2 <br />E <br />0 <br />s <br />a <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY <br />son <br />TERMINATIOl' <br />NEC 14, 250.94—/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />opper to lights & outlets <br />opper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />i Alu <br />----------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC, <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />61. <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />a <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />HD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />WWI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />^®^ <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />A9 <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />RI III r)FR <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />V <br />Z f7 <br />_ O <br />Z N <br />Z QQQ <br />Q <br />t� z <br />cL^n' c9 <br />� <br />u.i <br />�o <br />�V <br />— <br />O LU <br />(� <br />o <br />Co rl- <br />lV <br />Lit <br />m M m <br />f` M <br />'O <br />O o 0 <br />y� <br />C) r/l <br />L ILL 00 <br />00 <br />0 @ <br />Qm <br />CO <br />�g <br />rn Q d <br />A 1 <br />B D® <br />N C a D C <br />N �D <br />V cq� �t <br />v <br />LC UA `� M C.5 z <br />r J c <br />CC w <br />W Nam. o w <br />-0 <br />� W <br />05 <br />0 °x <br />H.�cc, <br />�Z Q�'��� <br />LUNdM Q <br />a� <br />O U U OO <br />W W W.FDSENG.COM <br />0 <br />0 <br />N <br />d7 <br />ct, <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and spedfications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />A <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />O Z <br />tt0 <br />3Q <br />Z <br />S� <br />L <br />W<== <br />J <br />oo�� <br />Z U Q <br />L.L. <br />�O� ZZ <br />J <br />� a � <br />Q <br />oho <br />U <br />U W N <br />�O <br />L <br />Z z <br />ro <br />r> <br />I— <br />U <br />f Z <br />Z <br />Z <br />n <br />LU <br />Q <br />LU <br />�}�'�� <br />V <br />cc <br />a <br />J w <br />O <br />Q <br />V <br />Ln <br />O <br />1 <br />�O - �0r <br />QYeP <br />,�,,:_ ,, <br />i a <br />p <br />, <br />L.L <br />7 <br />Z,= <br />w$7m <br />N <br />_ <br />Q <br />OW <br />ZLUZ <br />�€ <br />C <br />¢ <br />wWLu <br />Q <br />0oW <br />Z <br />Z <br />o° <br />ww <br />LU <br />Lr) <br />Uj <br />Q <br />Z <br />8 Uwe <br />a <br />g Fw <br />Z <br />Ln <br />(V <br />�O <br />Z <br />� W. <br />�ZS <br />..�..;//r..., <br />Z <br />to o <br />M <br />W <br />O <br />00 <br />g <br />tLl <br />= <br />aUVJI <br />Z <br />rn <br />,--I <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 3/29/2018 <br />TECH: JMUROSKI <br />VERSION NO. 5ol <br />SHEET NO. <br />4.0 <br />- - I - - - - <br />: ___T-rrM-n �T l � I rnF71FTF�tI 3i'd I FsT� i r.;.:1 <br />