My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
33626 Stella Vast Dr
Zephyrhills
>
Building Department
>
Building Plans
>
33626 Stella Vast Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 12:50:52 PM
Creation date
2/19/2025 11:30:59 AM
Metadata
Fields
Template:
Building Plans
Street #
33626
Location
Stella Vast Dr
Contractor
DR Horton
Building Plans - Permit #
22679
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT 5MLL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER PBC 6TH EDITION (2011) MECHANICAL SLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 101 CLASS I AIR DUCT AS PER NFPA WA 2.3U <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALE. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TF4 EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRICTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603A <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBG 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO DE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL, HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOOR$ TO <br />RESET DAMPER ALL DAMPERS $HALL BE INSTALLED TO MMG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH 15ALANCM DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX .ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TR W <br />l <br />BALANCING DAMPER OR OBD <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />B <br />PA88-THRU AIR GILL <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE PPE. ELEVATION. <br />r/L <br />\\ / <br />6. <br />0 <br />ALL HVAC TO HAVE PROPER <br />12X8 <br />- --- <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. <br />CONDENSER <br />- - - - - - - - - - - - - - - - - - - - <br />10X6 <br />ATTIC <br />W/ (2)-3/16'X2' TAPCONS <br />UNIT <br />N WB ROLL STRAP <br />I I <br />I <br />144XI4 <br />O <br />OR EQUAL <br />OR EQUAL <br />4'� 50 <br />0 <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />a6 CR'I <br />PLENUM <br />T <br />y <br />AIR RETURN:114 <br />4' CONCRETE SLAB <br />SECURE STRAP TO UNIT W/ (2) <br />bXl 1/4' SHT. MTL. SCREWS <br />' ' <br />I <br />14' <br />- - - - - - <br />SUCTION AND LIQUID <br />i I uRICHE <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />AIR HANDLER <br />y <br />CONNECTION <br />TO PAD <br />LAUN i n <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />O <br />OVER HEAD • 12' FROM STRUCTURE <br />3 <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />O <br />I Ii <br />BDRM. 4/ <br />T <br />REFRIGERANT LINES TO <br />T <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />1 <br />I 10X6 <br />4-0 RIER <br />TRAP DRAIN LINE AND TERMINATE <br />V.TR <br />IN AN APROVED DRAIN, AS PER <br />.� <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 301.2A <br />- - <br />HVAC <br />DRAINS <br />10"6 '®' - <br />4' LO <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FM. FLOOR <br />OR WALL <br />COUNTERSUNK <br />GA. PLUG <br />� <br />14X6 <br />f`rG�JI 1, II <br />gg�0 <br />GFM 8X4 I I I <br />1 <br />BATH # I <br />I ° <br />L-----J <br />14X6 �I 4 <br />SEE SPEC <br />rplu <br />'4 I <br />(.ARA[.R <br />�T <br />�-FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 86000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTIMPEC <br />nFL00R SLAB CLEAN -OUT (TYP. <br />FIN. GRADE <br />OR PAVING <br />I'-8'Xe' CONC. <br />FITTING OR <br />EXTENSION TO $OIL <br />OR WASTE AS <br />REQUIRED <br />nEXT. GROUND CLEAN -OUT (T <br />MECHANICAL PLAN <br />SCALE: 1/4 . P-0' <br />1441 N. RONALD REAOAN BLVDJ <br />LONGWOOD, FL 32750 <br />PH: 407-7744078 <br />FAK 407-7744078 <br />www.abdesigngroupcom <br />AA A: 0003325 _ <br />Q <br />a <br />p <br />pp <br />W�U <br />88HDm & ULOT: <br />SILVERADO <br />LOT 3 <br />BLK 19 <br />04128.002 03191 <br />moDZxA <br />4EBB <br />"1828—CALI" <br />GARAGE 81117aMs: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />
The URL can be used to link to this page
Your browser does not support the video tag.