My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35534 Stella Vast Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35534 Stella Vast Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 8:54:34 AM
Creation date
2/19/2025 11:08:41 AM
Metadata
Fields
Template:
Building Plans
Street #
35534
Location
Stella Vast Dr
Contractor
DR Horton
Building Plans - Permit #
324
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING, ALL SEAMS SHALL 0E SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED A8 PER PBC 6TH EDITION (2011) MECHANICAL OLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SMALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA 90A 2-3.1 <br />4. FRESH AIR INTAKES SMALL NOT BE LOCATED CLOSER THAN 10 FT. PROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SELLER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF BMOOTW GAI-V. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 6033 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SMALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (20P1) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9, ALL FIRE RATED CEILINGS AND WALLS SMALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SMALL BE INSTALLED TO MFG. RECOMMENDATIONS AND MC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO 6E A FANTECM DBF BOOSTER PAN OR EQUAL. <br />PANTEC 4 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRLW <br />— <br />BROKEN LINE. RETURN TRUNK <br />BALANCING DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTEr <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. <br />CONDENSER <br />ATTIC <br />W/ (2)-3/16'X2' TAPCONS <br />UNIT <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM I <br />T <br />y <br />AIR RETURN <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB GSXI 1/4' SHT. MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER UNIT <br />AIR HANDLER <br />y <br />CONNECTION TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN COND. DRAIN 3/4' DMA. <br />OVER HEAD • 12' PROM STRUCTURE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW BLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN. AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLOG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL /—FIN. FLOOR COUNTERSUNK <br />BRONZE FL. PL. --,,—OR WALL CA. PLUG <br />BRA68 PLUG <br />—"�--FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V,C OPTIAMC <br />FLOOR SLAB CLEAN -OUT (TYPN� <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-S'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />nEXT. GROUND CLEAN -OUT (TYPN <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE PPE. ELEVATION <br />MECHANICAL PLAN <br />ALE: 1/4 " P-0' <br />1441 N. RONALD REAGAN BLVD, <br />LONGWOOD, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-7744078 <br />www.abdosigngroup.com <br />` AA M: 0003325 <br />• <br />4kk1 <br />04 <br />ii <br />SL <br />o <br />SILVERADO <br />LOT #31 <br />BLK #18 <br />D1 PROJECT* <br />.`/�\J1�i 04128.002-31181 <br />ZILODEEa <br />4EAB <br />"1672- ARIA" <br />GARAGE SWU40: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EX1% B <br />J`;°" <br />ir7'rE: 06/09/20 <br />SCALE: 1/4"=l'—O" <br />BCT <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.