My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35548 Burma Reed Dr (2)
Zephyrhills
>
Building Department
>
Building Plans
>
35548 Burma Reed Dr (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:01:51 AM
Creation date
2/19/2025 12:27:47 PM
Metadata
Fields
Template:
Building Plans
Street #
35548
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
396
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SMALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB / MASTIC. AND <br />INSTALLED AS PER MO 6TH EDITION (2011) MECHANICAL 15LM CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS 614ALL BE CONSTRUCTED IN ACCORDANCE TO MC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WTN FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS SMALL, HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCE86 DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG, RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />W. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTEC 4 OBF BOOSTER FAN OR EQUAL. <br />FANTECI-I DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE" RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 1 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PAS6-THRU AIR GRILL <br />MOTE <br />ALL WVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. <br />CONDENSER <br />ATTIC <br />W/ !2)-3/16'X2' TAFCCNS <br />WIT <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />T <br />y <br />AIR RETURN <br />SECURE STRAP TO WIT W/ (2) <br />4' CONCRETE SLAB G8X1 1/4' SHT. MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER UNIT <br />AIR HANDLER <br />y <br />CONNECTION TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE, MAN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />EVAP. TRAY <br />SLEEVE TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFORM <br />MvMECWANICAL5LCaCO0E <br />CONDENSING WIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />SECTION 3012A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR COUNTERSUNK <br />BRONZE FL. PL. OR WALL CA. PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />//-- WADE 8240-K X6AM 56000 <br />INSIDE SERIES NICKEL BRA86 TOP <br />CAULK P.V.0 OPTI/SPEC <br />vFL00R SLAB CLEAN -OUT (T <br />FN. GRADE <br />OR PAVING <br />SEE SPEC. <br />1'-8'X6' CONC. <br />FITTING OR <br />EXTENSION TO 601L <br />OR WASTE AS <br />REQUIRED <br />DEXT. GROUND CLEAN -OUT (TYPN <br />NOTE: <br />ALL. MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE FPE. ELEVATION. <br />MECHANICAL PLAN <br />SCALE, 1/4 " 1'-0' <br />:El:l <br />F, q4 <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />W W W.Obdosigngroup.com <br />AA 8: 0003326 <br />at <br />iPPlo <br />O <br />SUDDiv ac mmll: <br />SILVERADO <br />LOT #32 <br />BLK #18 <br />PROJECT# <br />04128.002-32181 <br />MODELa <br />4EBB <br />"1828—CALI" <br />GARAGE BWD90: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />a <br />PAINT <br />DATjM 06/09/20 <br />SICALM: 1/4"=1'-0" <br />8HEET <br />M1 <br />