My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35549 Stella Vast Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35549 Stella Vast Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:04:48 AM
Creation date
2/19/2025 11:14:55 AM
Metadata
Fields
Template:
Building Plans
Street #
35549
Location
Stella Vast Dr
Contractor
DR Horton
Building Plans - Permit #
300
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EGIIPMENT &HALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MF& REG)IREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH CLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (201T) MECHANICAL 15LM CODE SECTION 603. <br />3.. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS 1 AIR DUCT AS PER NFPA 90A 2-3.1 <br />4. FRESH AIR MAKES SHALL NOT BE LOCATED CLOSER THAN W FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (20T1) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRICTED IN ACCORDANCE TO MC 6TH EDITION <br />(201) MECHANICAL CODE 603J <br />1. BATHROOMS CONTANNG BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHNG FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EGJAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCNG DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTEC14 DBF BOOSTER FAN OR EQUAL. <br />FANTEC4 DBF ILV DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TIQLW <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LnHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />B <br />PASS-THRI AIR GRILL <br />NOTE <br />ALL HVAC TO NAVE PROPER <br />PANS W/ DRAMS <br />SECURE STRAP TO COW— CONDENSER <br />ATTIC <br />W/ (2)-3A(P'X2' TAPCONB <br />SIMPSON WB ROLL STRAP <br />OR EGJAL <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />AIR RETURN <br />4' CONCRETE SLAB <br />SECURE STRAP TO UNIT WY <br />48X1 1/4' SHT. MTL. SCREWS <br />(2) <br />SUCTION AND LIG)ID <br />AIR SUPPLYA <br />nERANT LINES <br />CONDENSER <br />UNIT <br />AIR HANDLEREXTERIOR <br />CONNECTION <br />TO PAD <br />WALL <br />3/4'PVC CONDENSATE DRAM LNE <br />M <br />NOTE, MAIN COND. DRA3/4'DIA.OVER <br />HEAD 12'FROM STRUCTURE <br />EVAP. TRAY <br />PVC SLEEVE TO LINES BELOW SLAB <br />-11 <br />p <br />REFRKaERANT LINES TO <br />PLATFOW <br />RETURN <br />CONDENONG UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAM, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />EEO <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FM. FLOOR <br />OR WALL <br />COUNTERBINC <br />Co. PLUG <br />� <br />� <br />.. <br />SEE SPEC. <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 824ID-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.VG OPTI/SPEC <br />vFL00R SLAB CLEAN -OUT (T <br />FIN. GRADE <br />OR PAVING <br />1'-8'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REGIIRED <br />NEXT. GROUND CLEAN -OUT (TYPN <br />MECHANICAL PLAN <br />SCALE: 1/4 • 1'-0' <br />NOTE: <br />ALL MECHANICAL EGIIPMIENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774- <br />FAX 407-7744078 <br />www.abdesW gmup com <br />AA 1/0003326 <br />f <br />ft <br />r <br />a <br />SUHDIV, de LOT: <br />SILVERADO <br />LOT 25 <br />BLK 18 <br />PlmoJECT# <br />04128.002 25181 <br />1RODEL- <br />4EBB <br />"1828-CALI" <br />GARAGE 81 WO: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />QA <br />"'i6v"'�9-i'L4-T <br />DA04/06/20 <br />SCALE: 1/4"=l'-0" <br />SHEET <br />M1 <br />