My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35555 Stella Vast Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35555 Stella Vast Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:07:58 AM
Creation date
2/19/2025 11:31:17 AM
Metadata
Fields
Template:
Building Plans
Street #
35555
Location
Stella Vast Dr
Contractor
DR Horton
Building Plans - Permit #
301
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EGUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REdJIREMENTS. <br />2- ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRICTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2Ol) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 01 CLASS I AIR DUCT AS PER NFPA WA 2-3) <br />4. FRESH AIR INTAKES SWALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH CiALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2OT1) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINNG BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHNG FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILING AND WALLS SWA,L HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILM OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMI'ENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DPP"RS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF I10 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />4 <br />CEILING EXHAUST FAN <br />CEILNG EXHAUST FAN a LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />B <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE FPE. ELEVATION. <br />NOTE <br />riL 6. <br />p <br />44, <br />ALL HVAC TO HAVE PROPER <br />12XS <br />PANS W/ DRAWS <br />SECURE STRAP TO CONC. <br />CONDENSER <br />- - - - - - - - - <br />ATTIC <br />W/ (2)-3/Wr'X2' TAPCCNS <br />UNIT <br />SIMPSCN WO ROLL STRAP <br />I <br />µxµ <br />O <br />OR EQUAL <br />4' <br />4' U. <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />- ---i <br />- - - - - - - - <br />X6 - TH <br />PLENUM <br />AIR RETURN <br />SECURE STRAP TO UNIT W/ (2) <br />° ° <br />I <br />14' <br />4' CONCRETE SLAB <br />°BXI 1/4' SHT. MTL. SCREWS <br />- - - - - - <br />SUCTIONAND LKdU1D <br />jjTcu <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />`- ---` <br />AIR HANDLER <br />y <br />CONNECTION <br />TO PAD <br />a�;;1 <br />LAUN <br />EXTERIOR L WAL <br />---- <br />y <br />3/4' PVC CONDENSATE DRAM LINE <br />NOTE: MAN COJD. DRAIN 3/4' DIA <br />�� <br />OVER HEAD tt' FROM STRUCTURE0 <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />O <br />_ _ _ <br />` - <br />I <br />BDRM. 4 / <br />T <br />REFRIGERANT LINES TO <br />- - - - T <br />PLATFORM <br />RETURN <br />CONDENSED UNIT <br />I <br />1 I I0X6 <br />DRYER <br />TRAP DRAIN LINE AND TERMINATE <br />i <br />i4' <br />V.7R <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />I <br />_ <br />HVAC <br />DRAINS <br />10 <br />�X6Inr <br />4' LI <br />- - <br />O <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN. FLOOR <br />OR WALL <br />COUNTERSUNK <br />C.O. PLUG <br />. � �� <br />I <br />1, I <br />II <br />CFM 8X4 i I I <br />BATH if 2 <br />L J <br />a <br />I'-6' <br />®A 8X4 <br />_—SEE SPEC <br />('yARArF. <br />BRASS PLUG <br />—'�--FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K "AM 86000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />nFLOOR SLAB CLEAN -OUT (TYPj <br />FIN. GRADE <br />OR PAVING <br />r-Ja'xv C0W— <br />FITTIN53 OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />gEXT. GROUND CLEAN -OUT (TYPN ) <br />MECHANICAL PLAN <br />SCALE: 1/4 ° I'-& <br />f <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL32750 <br />PH: 407-774E078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA is 0003325 <br />w <br />L4 <br />64 <br />u <br />UBLJSDIV >k LOT: <br />SILVERADO <br />LOT 24 <br />BLK 18 <br />PROJECT# <br />04128.002 24181 <br />3tOD=. <br />4EBB <br />"1828—CALI" <br />GARwGE swsrrO: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />