My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35583 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35583 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:35:34 AM
Creation date
2/19/2025 12:14:15 PM
Metadata
Fields
Template:
Building Plans
Street #
35583
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
403
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB a MASTIC. AND <br />INSTALLED AS PER MC 6TH EDITION (2011) MECHANICAL ELM CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NPPA WA 2-3J <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. PROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER MC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALT. HAVE AN APPROVED FIRE OR FIREAMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11, DRYER 0006TER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />NCTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />arrlc <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />1 <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />p <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION W12A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />FfTTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JO8AM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN —OUT (TY�PN.) <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIPFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LI&4T <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />_211111 <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ l2J <br />'ill I/4' SHT. P1TL. 6CREW8 <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />CA. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />., I'-8'X8' CONC. <br />FITTINCs OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />vEXT. GROUND CLEAN —OUT (T <br />NOTE, <br />ALL MECHANICAL EQUIPMENT <br />814ALL DE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />MECHANICAL PLAN <br />SCALE, 1/4 . 1'-0' <br />1441 N. RONALD REAGAN BLVD, <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA M: 0003325 <br />ltlt6 <br />a <br />r <br />kk <br />�K <br />SILVERADO <br />LOT #12 <br />BLK #19 <br />Do <br />04128.001-1219 <br />MODsrl <br />4EAB <br />"1979- AATA" <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />!12 , <br />A <br />NO <br />A wTS: 08/09/20 <br />!!CALF: 1/4"=1'-0" <br />splZmT <br />M1 <br />