My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35586 Stella Vast Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35586 Stella Vast Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:38:14 AM
Creation date
2/19/2025 11:41:24 AM
Metadata
Fields
Template:
Building Plans
Street #
35586
Location
Stella Vast Dr
Contractor
DR Horton
Building Plans - Permit #
212
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT 814ALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICMG, PER <br />MF& REOLIRENENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS $WALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATNG. ALL SEAMS SHALL 13E SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (20111) MECHANICAL SLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS i AIR DUCT AS PER NFPA WA 2-3U <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHINNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (20n) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED N ACCORDANCE TO FBC 6714 EDITION <br />(2011) MEC 4MICAL CODE 603.1 <br />T. BATHROOMS CONTAINMfs BATHTUBS, SHOWERS, SPAS AND SIMILAR BAT14MG FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403, <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />* ALL FIRE RATED CEILINGS AND WALLS 814ALL HAVE AN APPROVED FIRE OR FIRE/SI'100M <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATION AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCMG DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LNE• RETURN TRW <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />.� <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />T14ER'IOSTAT <br />B <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAIN <br />SECURE STRAP TO CONC. CONDENSER <br />ATTIC <br />W/ (2)-3/16'X2' TAP'CONS UNIT <br />SIMPSON WB ROLL STRAP <br />OR EGLAL <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLC <br />T N <br />AIR RETURN <br />SECURE STRAP TO UNIT W/ <br />(2) <br />4' CONCRETE SLAB <br />$XI 1/4' SHT. MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />N <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />AIR HANDLER <br />y <br />CONNECTION <br />TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN COND. ORAN 3/4' DIA. <br />OVER HEAD • 12' FROM STRICTURE <br />EVAR TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES 70 <br />PLATFOR1 <br />RETURN <br />CONDENSING WIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />EEO <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />� <br />FIN. FLOOR <br />OR WALL <br />COUNTER <br />GA. PLUG <br />� <br />SEE SPEC. <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V:C.OPTI/SPEC <br />T4FL00R SLAB CLEAN -OUT (T <br />FIN. GRADE <br />OR PAVMG <br />I'-13'XN3' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />DEXT. GROUND CLEAN -OUT (TYP.) <br />N <br />MECHANICAL PLAN <br />SCALE: 114 • 1'-0' <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX, 407-774-4078 <br />www.abdeaigngroup.com <br />AA #: 0003325 <br />14 <br />14 <br />S <br />eIm <br />mll <br />SLJHDIV. & LOT: <br />SILVERADO <br />LOT 7 <br />BLK 19 <br />PROJECT#I <br />04128.002 07191 <br />MODEM <br />4EBB <br />"1828-CALM' <br />GARAGE S'WMG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />[PApTE 004/06/20 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.