My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35587 Stella Vast Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35587 Stella Vast Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:40:55 AM
Creation date
2/19/2025 11:09:11 AM
Metadata
Fields
Template:
Building Plans
Street #
35587
Location
Stella Vast Dr
Contractor
DR Horton
Building Plans - Permit #
213
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL E42UIFI ENT SMALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICMCs, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED M NON -CONDITIONED AREAS 844ALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL W CLASS 1 AIR DUCT AS PER NFPA WA 2-3J <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL. BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FSC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (20I1) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH OBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF NO DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRJJG <br />— <br />BROKEN LINE. RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OSD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN t LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />NOTE <br />D� <br />I <br />1 <br />----� <br />ALL µVAC TO HAVE PROPER <br />�j CH <br />7G <br />i <br />— <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. <br />CONDENSER <br />ATTIC <br />W/ (2)-3A6'X2' TAPC0NS <br />UNIT <br />SMF'9CN LLB ROLL STRAP <br />�. I ��--- <br />- <br />OR EQUAL <br />ii <br />BATH PAL <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />�W, <br />-- <br />PLENUM <br />? <br />1 <br />AIR RETURN <br />4' CONCRETE SLAB <br />SECURE STRAP TO UNIT W1 (2) <br />G8XI V4' SHT. MTL. SCREWS <br />BD M.#� <br />$ 3 <br />------ <br />------ <br />O <br />— <br />�• <br />I <br />I <br />I <br />RUCTION AND LIQUID <br />AIR SUPPLY <br />a <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />a <br />AIR HANDLER <br />1 <br />CONNECTION <br />TO PAD <br />�• <br />LAUN. <br />° <br />EXTERIOR WALL <br />III w� <br />y <br />3/4' PVC CONDENSATE DRAM LINE <br />NOTE: MAN CONO. DRAIN 3/4' DIA <br />es <br />I 4' <br />OVER HEAD R' FROM STRUCTURE <br />III <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW BLAB <br />III <br />8X4 � O Y <br />T <br />REFRIGERANT LINES TO <br />`0 <br />PLATFORM <br />RETURN <br />C0NDENONG UNIT <br />— — — — — — <br />4' <br />TRAP DRAIN LINE AND TERMINATE <br />L <br />4' DRYER <br />IN AN APROVED DRAIN, AS PER <br />5' <br />V.T.R. — — — — — O <br />FBCR 6TH EDITION (2011) <br />CODE <br />SECTION 3012BLDG. <br />50 <br />HVAC <br />DRAINS <br />e BX4 <br />it <br />II <br />II <br />— — — — — — — — 44X6 FOYER <br />GARAGE <br />SCORIATED NICKEL <br />BRONZE FL PL. <br />FIN. FLOOR <br />OR WALL <br />COUNTERSUNK <br />C.O. PLUG <br />I2XS <br />— — — <br />BDRM•#�2 <br />i— SEE SPEC. <br />—� FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56MV <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V:C OPTI/BPEC <br />DFLOOR SLAB CLEAN —OUT (TYEJ <br />N <br />FIN. GRADE <br />OR PAVING <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />vEXT. GROUND CLEAN —OUT (TYY <br />MECHANICAL PLAN <br />SCALE: 1/4 . I'-0' <br />1441 N. RONALD RFAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA M. 0003325 <br />i <br />0 <br />o <br />i <br />aysDiv ae LAT <br />SILVERADO <br />LOT 21 <br />BLK 18 <br />PROJZCT# <br />04128.002 21181 <br />MODZI.: <br />4EAB <br />"1672—ARIA" <br />GAP-hOM Ellr M: <br />RIGHT <br />PAGE <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />
The URL can be used to link to this page
Your browser does not support the video tag.