My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35592 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35592 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:43:30 AM
Creation date
2/19/2025 12:14:46 PM
Metadata
Fields
Template:
Building Plans
Street #
35592
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
552
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT 814ALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />Mm. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS $HALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAD 4 MASTIC, AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL DLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 161 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FDC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6114 EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS QHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND DE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A PANTEC 4 OBF BOOSTER FAN OR EQUAL. <br />PANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />CEILING <br />PLENUM <br />AIR SUPPLY <br />AIR HANDLER <br />EVAP. TRAY <br />PLATFORM <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN s LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE, <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS SECURE STRAP TO CON-. CONDENSER <br />ATTIC W/ (2)-3/161X1' TAP-ONS UNIT SIMPSON WB! ROLL STRAP <br />OR EQUAL <br />EXTERIOR WALL O O <br />t y AIR RETURN 4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />_ NOXI 1/4' SHT. MTL. SCREWS <br />SUCTION AND LIQUID <br />y REFRIGERANT LINES <br />y <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />q <br />REFRRIERANT LINES TO <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TER11NATE <br />IN AN APROVED DRAIN, AS PER <br />k��MECHANICAL <br />FBCR 6TH EDITION (2011) <br />BLDG. CODE <br />SECTION 3013.4 <br />HVAC <br />DRAINS <br />SOMATED NICKEL FIN, FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />-�-FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />(D LOOR SLAB CLEAN -OUT (TYPN� <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE. MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />CA. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />T-e'Xe' -ONC. <br />FITTW.m OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT- GROUND CLEAN -OUT (TYP <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />MECHANICAL PLAN <br />SCALE: 1/4 - P-0' <br />■ <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />wwwAbdosigngroup.com <br />AA (h 0003325 <br />13 <br />C <br />a <br />6 <br />14 <br />av9DIV So LOT: <br />SILVERADO <br />LOT #39 <br />BLK #18 <br />PROJECT <br />04128.601-39181 <br />11[ODELa <br />4EBB <br />"1828-CALI" <br />GARAGE OWING: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 KPH 9XP. B <br />DaINT <br />AUCE'. 07/27/20 <br />8CAI E: 1/4"=l'-0" <br />snow <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.