My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35600 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35600 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:53:27 AM
Creation date
2/19/2025 12:02:12 PM
Metadata
Fields
Template:
Building Plans
Street #
35600
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
569
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHA,L, BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATINGG, ALL SEAMS SHALL BE SEALED WITH GLASS FA15 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (20n) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCT$ SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINNG BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9 ALL FIRE RATED CEILINGS AND WALL$ SHALL. HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILNG OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPER$ SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 60T. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH SALANCING DAMPERS. <br />It. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />PANTEC 4 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE• <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />EXTERIOR WALL <br />PLENUM <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />T�Z/� <br />REFRIGERANT LINES <br />AIR HANDLER <br />EXTERIOR WALL <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAYPVC <br />SLEEVE TO LINES BELOW SLAB <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LIKE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />(, <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAPCONS UNIT SIMPSON WS ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />ffiXI 1/4' SHT. MTL. SCREWS <br />T REFRIGERANT LINES TO <br />PLATFORM RETURN CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.4 <br />HVAC DRAINS <br />SCORIATED NICKEL /—FIN. FLOOR <br />BRONZE FL. PL. / OR WALL <br />BRASS PLUG <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />C.O. PLUG <br />SEE SPEC. <br />1'-e'x8' CONC. <br />I I FIN. GRADE' <br />FITTING OR EXTENSION TO OR PAVING <br />SOIL OR WASTE A5 <br />REQUIRED FITTING OR <br />EXTENSION TO SOIL <br />WADE 8240-K J06AM D60M OR WASTE AS <br />INSIDE SERIES NICKEL BRASS TOP REQUIRED <br />CAULK P.V.0 OPTI/SPEC <br />NV. SEE <br />817E PLAN �INv. SEE <br />I'►S TE PLAN <br />FLOOR SLAB CLEAN -OUT (TYPN� vEXT. GROUND CLEAN -OUT (TYPN.) <br />■ <br />MECHANICAL PLAN <br />SCALE. 1/4 " I'-C' <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL32750 <br />PH: 407-7748078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />6 <br />• <br />Gi <br />� <br />2 <br />� <br />m <br />Lk <br />aVHDM ac L,0711 <br />SILVERADO <br />LOT #40 <br />BLK #18 <br />PROJECT <br />04128.001-40181 <br />MODELe <br />4EAB <br />"1672-ARIA" <br />GARAGE 9Wn4G: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />D � 07/30/20 <br />8CAL.E: 1/4"=1'-0" <br />SHEET <br />M1 <br />