My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35603 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35603 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:58:38 AM
Creation date
2/19/2025 12:13:09 PM
Metadata
Fields
Template:
Building Plans
Street #
35603
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
566
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(W AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SECAJENCE OF FLASHING TO BE: <br />1. BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP 16 TO BE SET IN DED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES. Ys' CAULKING a JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />E)twW NMft and WasWft <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />MRS LAYER M, <br />STUCCO WRAP <br />'x <br />HOODED VENT <br />J' T141M 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER 4, FORTP115ER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER ------ <br />BUILDING PAPER) <br />METAL LATH x-x-x-x <br />STUCCO <br />SELF-ADHESIVE FLASHING - - - - - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-OS, MIN, 2B L55. <br />PER $0. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELEC. METEF <br />VERIFY LO <br />STUCCO <br />FINISH <br />Co' SELF ADHESIVE <br />OVER TOP t: SIDES <br />SELF <br />WOOD SHEATHING <br />FLASHING <br />LAYER 01, <br />UNIT <br />STUCCO WRAP <br />LAYER 4, FORTIFIBER <br />F'REMANUF. DRYER <br />BUILDING PAPER <br />VENT CAP (SET IN <br />METAL LATH <br />CONT. SEALANT) <br />WO= <br />-PINION <br />CONSTRJCTiON <br />f a wow <br />FA6TEN TO WOOD STPIUCT RAL <br />SEALANT • <br />; MEMBER a T' OG. MAX <br />TOP 4 SIDES <br />s <br />�$i TOY <br />F)B DRYER VENT (BLOCK <br />BUILDING PAPER <br />OVER 'O.UICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />I <br />6' SELF ADWESIVE— <br />FLASHING (INSTALL <br />PER MAN. F. SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />.+r�Gr+ IV I�GVGIYG <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />rl�eLE <br />LY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />. METER FIELD <br />IFY LOCATION <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />)R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />,O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED WOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWANO MEMBRANE <br />ENTERS BOx, <br />APPLY TO FAX <br />EDGE <br />APPLY E-Z <br />OVER be MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />EF,M <br />6' WIDE STRIP SELF <br />ApHE91VE FLASHING, CLEAN <br />MASONRY BEf ORE APPLYING <br />V PINION a MASONRY <br />(?�HORIZONTAL WEEP SCREED <br />(FRAME TO BLOC <br />WRE1 LAYER 4, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF-ADHERINGMEMBRANE <br />FLASHINGAPPLY <br />SELF-ADHERINGMEMBRANE <br />FLASHINGOVER <br />BOX AND OVER <br />APPROVED WRB LAYER <br />hSTEP <br />#1 <br />STEP #2 <br />UIRSTU LAYER 01,STUCCO <br />WRAP <br />APPLY 6m MIN - <br />GRADE 'D'FELT <br />OVER <br />SELF-ADHERINGFLASHING OVER <br />APROVED <br />WOUSEWRAP <br />STEP #3 <br />M MBRANE FLASHING <br />WRB LAYER 7, FORTIFIBER <br />BUILDING PAPER <br />STEP *4. <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />n_ METAL LATH <br />STEP #5 STEP #6OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD,FL32750 <br />PN: 407-774-6078 <br />FAX 407-774-4078 <br />www.abdosigngroup.com <br />AA 8: 0003325 <br />0 <br />UDDIV as I.OT:SILVERADO <br />LOT #14 <br />BLK #19 <br />PROJECTp04128.002-14191 <br />"MODEIt"4EWB <br />1499-FREEPORTGARAGE EWWO: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />
The URL can be used to link to this page
Your browser does not support the video tag.