My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35620 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35620 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:14:24 AM
Creation date
2/19/2025 12:08:53 PM
Metadata
Fields
Template:
Building Plans
Street #
35620
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
682
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEC mur's OF FLASHING TO BE, <br />1. BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED 80 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROWD <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Yi CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />EAwlor lBtlVrIG and pla (left <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER -1, <br />..x <br />_ <br />STUCCO WRAP <br />I <br />I . <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT ( FRAME.) <br />LEGEND <br />DRAINAGE PLANE (LURB <br />LAYER 01, STUCCO LURAP) <br />UJRB LAYER "2 (FORTIFIBER - - - - - - <br />BUILDING PAPER) <br />METAL LATH x-x-x-x <br />STUCCO <br />SELF-ADHESIVE FLASHING - - - - - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-0% MIN. 2.5 L55. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT <br />TOP 4 SIDES <br />(9 DRYER VENT ( BLOCK) <br />BUILDING PAPER <br />OVER 'GMIC:K <br />FLASH' <br />PIPEL THROIXaHWAL <br />6' 6ELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MARV.SPECS.) <br />BUILDING PAPER — <br />WDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.TS. <br />ELEC. METEF <br />VERIFY LO <br />F•1RC.w I V RCtiC I V C <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W BACK - <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />`ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (I) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER el, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANI <br />ENTERS BOX, <br />APPLY TO FAI <br />EDGE <br />APPLY E-Z <br />OVER 6® M <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT Al <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHEATHING <br />WRB LAYER 4, <br />STUCCO WRAP <br />WRB LAYER R, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRJCTURAL <br />Mh..hIDER • 1' OL. MAX <br />1TO N M --WAL <br />'. �� <br />•' WIDE STRIP SELF <br />ADNESNE FLASHING, CLEAN <br />MASONRY DEPOW ArPLYINd. <br />FINISH • MASONRY <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />U1RS LAYER M, <br />STUCCO WRAP <br />STEP #1 <br />APPLY 60 MIN <br />GRADE 'D' FELT <br />OVER <br />SELF-ADHERNCs <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP #3 <br />S• <br />STEP #2 <br />WRB LAYER h, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />�- WRB LAYER 62, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />ti METAL LATH <br />STEP #5 STEP No <br />(1)ELECTRICALRECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7748078 <br />FAX 407-7744078 <br />wwwAbdeslgngroup com <br />AA N: 0003326 <br />117 <br />94 <br />:a <br />o <br />BUDDIV A LAT <br />SILVERADO <br />LOT #42 <br />BLK #18 <br />PROd10CT* <br />04128.002-42181 <br />1[ODEIt <br />4EBB <br />"1828-CALI" <br />GARAGE BIWMG: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />%150 MPH EXP. B <br />