35629 Stella Vast Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35629 Stella Vast Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:22:21 AM
Creation date
2/19/2025 11:08:57 AM
Metadata
Fields
Template:
Building Plans
Street #
35629
Location
Stella Vast Dr
Contractor
DR Horton
Building Plans - Permit #
22676
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MPG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLM CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603U <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH MC 6TH EDITION (20f1) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />8 ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRW <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILNG EXHAUST FAN <br />CEILNG EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />19 <br />PASS-THRU AIR GRILL <br />NOTE, <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />NOTE, <br />i L <br />— — — —I <br />ALL HVAC TO HAVE PROPER <br />W,Lc <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. <br />R <br />'OATTICW/ <br />(2)•3/167Q' TAPCONB <br />WIT <br />U!8 ROLL STRAP <br />F <br />4, <br />I <br />�IM� <br />� <br />O <br />SX4 <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />6' <br />— <br />PLENUM <br />AIR RETURN <br />4' CONCRETE SLAD <br />SECURE STRAP TO WIT W/ (2) <br />°SXI 1/4' SHT. MTL. SCREWS <br />�TScHErI <br />SUCTION AND LIQUID <br />I <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />10' i i i <br />IOx6 <br />F/L <br />Br1T�i <br />AIR HANDLER <br />y <br />CONNECTION <br />TO PAD <br />I <br />EXTERIOR WALL <br />_ _ _ _ _ _ — 10' <br />y <br />9/4' PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN DRAIN <br />HDRM.�{3 <br />10X6 <br />a 121 RU UR <br />OVER HEAD � 12' FROM STRUCTURE <br />O <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />I <br />p <br />REFRIGERANT LINES TO <br />— <br />O <br />PLATFORM <br />RETURN <br />CONDENSING WITDG. <br />�• <br />iii ii <br />LAUN•Z. <br />TRAP DRAIN LINE AND TERMINATE <br />6' <br />IN AN APROVED DRAIN, AS PER <br />4' <br />FBCR 6TH EDITION (2011) <br />j j PT <br />O0 <br />MECHANICAL BLCODE <br />8X4 1 <br />SECTION 301.2.4 <br />® <br />I <br />HVAC <br />DRAINS <br />_ <br />t4� <br />4' L <br />I 1 5' <br />II <br />--- <br />4' DRYER O <br />V.Tit <br />I I <br />SCORATED NICKEL <br />BRONZE FL. PL. <br />� <br />FIN. FLOOR <br />OR WALL <br />COWTERSUNK <br />Co. PLUG <br />1. <br />I I 8X4 <br />II <br />II <br />II <br />— — — — — — 1 <br />� <br />6 <br />SEE SPEC. <br />BRASS PLUG <br />--FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />//--WADE 8240-K JOSAM 56WO <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.v.0 OPTIAMO <br />vFL00R SLAB CLEAN -OUT (TYPN) <br />PIK GRADE <br />OR PAVING <br />I'-S'X&, CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT (TYP <br />MECHANICAL PLAN <br />SCALE. 1/4 . I'-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD,FL32750 <br />PH:407.774.6078 <br />FAX 407-7744078 <br />www.abdosigngfoup.com <br />AA #: 0003326 J <br />p <br />6 <br />r <br />p <br />MIN, <br />a$ <br />Q <br />Nit <br />i <br />SUNDIV. Ae I,OT <br />III <br />SILVERADO <br />LOT 17 <br />BLK 18 <br />PROJIDCT# <br />04128.002 17181 <br />MODZLc <br />4EAB <br />"1672— ARIA" <br />GAIeAGE 81WIMG: <br />RIGHT <br />PAGffi: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />