My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35647 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35647 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:35:53 AM
Creation date
2/19/2025 11:45:07 AM
Metadata
Fields
Template:
Building Plans
Street #
35647
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
748
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT @HALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER POO 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (20M) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOUTERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9 ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND POO 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />" '^" <br />O O <br />EXTERIOR WALL <br />PLENUM;uMECHANICAL <br />AIR RETURN <br />ON AND LIQUID <br />AIR SUPPLYGERANT <br />LINES <br />AIR HANDLERRIOR <br />WALL <br />VC CONDENSATE DRAIN LINE <br />EVAR TRAYLEEVE <br />TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFORMCONDENSING <br />UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED ORAN, AS PER <br />FBCR 6TH EDITION (2011) <br />BLDG. CODE <br />SECTION 3011.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.Vr_ OPTI/SFEC <br />FLOOR SLAB CLEAN -OUT TYNN <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE" RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />4 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />E3 <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3A6'X2' TAF'CONS UNIT SIMPSON WE, ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />48XI I/4' $WT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />CA. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-8'XB' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />■ <br />ZEXT. GROUND CLEAN -OUT (TYPN <br />MECHANICAL PLAN <br />SCALE: 1/4 • P-0' <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />1441 N. RONALD REAGAN BLVD, <br />LONGWOOD,FL32750 <br />PH: 407-774.6078 <br />FAX: 407.7744078 <br />www.abdealgngroup.com <br />AA #: 0003325 <br />74 <br />d <br />� <br />c <br />N <br />33 <br />6 <br />S <br />BtmDm Z LOT. <br />SILVERADO <br />LOT #18 <br />BLK #19 <br />PROJECT* <br />04128.002-18191 <br />MODEL: <br />4EBB <br />"1828-CALI" <br />GARAGE 9WDM: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH Effl. B <br />1 <br />ppaNT <br />DATE. 07/27/20 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />1VI1 <br />