35648 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35648 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:40:28 AM
Creation date
2/19/2025 11:56:47 AM
Metadata
Fields
Template:
Building Plans
Street #
35648
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
746
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL 6' SELF -ADHERING <br />MEMBRANE PLAS14M OVER <br />STUCCO <br />TOP, SIDE(S) AND BOTTOM <br />FINISH <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />6' SELF ADHESIVE <br />SECLOENCE OF FLASHING TO BE, <br />L BOTTOM, 2. SIDES, 3. TOP <br />OVER TOP 4 SIDES <br />X: VENT CAP 16 TO DE SET IN DED <br />SELF <br />WOOD 8FIE <br />OF SEALANT AT TOP AND <br />FLASHINt's <br />LAYERR M, <br />SIDES ONLY. SEALANT 16 TO DE <br />UNIT <br />STUCCO WRAP <br />TOOLED 60 AS TO DEFLECT <br />i WATER AWAY FROM JOINTS. <br />LATER 7, FORTIFIBER <br />1441 N. RONALD RFAGAN BLVD <br />zE-2 <br />PREMANUFDRYER <br />BUILDING PAPER <br />LONGWOOD, FL 327W <br />DEAD ALL AROUND <br />1 � VENT -APPLY SEALANT ALL <br />. <br />VENT CAP (SET IN <br />METAL LATH <br />PH:407-774-6078 <br />� JOINTS AND MTERSECTIONB <br />CONT. SEALANT)WOOD <br />6N DD <br />FAX: 407-7744078 <br />wwwAA <br />1 APPLY SEALANT AT PERIMETER OF <br />CON6TI®ICTION . ;�—�M <br />#: 000332p.com <br />AA M:11003328 <br />BACKER ROD NON -MOVABLE FRAME AND STUCCO <br />FASTEN TO WOOD STFI IOWRAL <br />• V OG. MAX <br />ON ALL SIDE&A CAULKING • JOINT <br />ALL AROUND <br />SEALANT <br />0' CM <br />I <br />TOP t SIDES <br />V 70 ' MID -WALL <br />PER SECTION R703.7 <br />WEEP &NW <br />EXta W IS ft slid plasteft <br />PACKER ROD 1 1 Exterior use of Portland cement plaster <br />shall comply with the application <br />6 B DRYER VENT (BLOCK) <br />A <br />{x, requirements of ASTM C 926-12A. <br />s' 6' WIDE STRIP SELF <br />.•1 <br />� ADM" FLASHING, CLEAN <br />Insta° of exterior lathing and framing <br />1 X shall comply <br />I 'X. shall comply with ASTM C 1063-12A. <br />i <br />MASONRY BEFORE APPLYING <br />WRB LAYER -1,�TEMUIIED <br />STUCCO WRAP � <br />FINI • M ASONW <br />I . • HOODED VENT <br />BUILDING PAPER <br />OVER 'QUICIG <br />HORIZONTAL WEEP SCREED <br />THICK 3COAT CEMIENT <br />FLASH <br />PLAS <br />— —� <br />(FRAME TO BLOCK <br />METAL LATH <br />— — <br />WRB LAYER 12, FORTIFIBER <br />PIPE THROUGH <br />WALL <br />BUILDING PAPER <br />WOOD SHEATHING <br />C <br />� <br />Fa <br />gg <br />DRYER VENT (FRAME <br />6' SELF ADHESIVE <br />FLASHING (INSTALL <br />PER MANUF.SPECS) <br />8' <br />BUILDING P <br />UNDER 01.11 FLAPER <br />ASH' <br />CUT OPENING INSTUCCOYER <br />WRAP <br />HOUSEWRAP <br />FOR BOX INSTALLATION <br />!;40APPROVED <br />CUT 'X' INTO <br />A VENT PENETRATION <br />WRD LATER h, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />k <br />SCALE: N.T.S. <br />x <br />APPLY SELF -ADHERING <br />WOOD SHEATHINCs <br />NG <br />RANE FLASOVEER <br />I <br />OVER BOX AND <br />APPROVED WRB LAYER <br />7 <br />STEP #1 <br />STEP <br />#2 <br />APPROVED <br />BE L60WEW¢AP <br />WRB LAYER 7, <br />STUCCO WRAP <br />ELEC. METER FIELD <br />I <br />VERIFY LOCATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />GUT SUCH THAT <br />® <br />APPLY 60 MIN <br />SELF -ADHERING <br />NO MEMBRANE <br />_ <br />GRADE 'D' FELT <br />® <br />1 MEMBRANE FLASHING <br />ENTERS BOX, <br />OVER <br />APPLY STUCCO SCRATCH COAT <br />APPLY TO FACE <br />SELF -ADHERING <br />AND ONE (1) LAYER OF PAINT <br />EDGE <br />A► DVER <br />PRIOR TO INSTALLING ELEC. <br />HOUSEWRAP <br />METER <br />ILM LAYER 02, FORTIF15ER <br />CAVITY TO BE FILLED <br />STEP 113 <br />BUILDING PAPER <br />19 <br />WITH RIGID POLYMERIC <br />STEP <br />#4 <br />LEGEND <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />ELASTOMERIC <br />DRAINAGE PLANE (L1R5 <br />BASE SEALANT AT POINT <br />COATING OVER <br />STUCCO/ G.V. IF <br />LAYER 01 STUCCO WRAP) <br />THAT ELEC WIRE PENETRATES <br />IEEE TYPICAL WALL <br />SUDDIV. a L°OT <br />SILVERADO <br />LOT #45 <br />BLK #18 <br />1r1t0jzCT# <br />04128.002-45181 <br />MODRIs <br />4EBB <br />"1828-CALI" <br />GARAOR BWMG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />APPLY E-2 DEAD— <br />OVERe.e.e SECTION) <br />WRB LAYER 02 (FORTIFIBER — — — — — GRDE 60 MIN METAL LATH <br />BUILDINGS PAPER) AREA TO RECEIVE <br />STUCCO SCRATCH COAT SEALANT AT DALL <br />METAL LATH X—X—X—X 4 1 COAT OF PAINT W/BACK- JOINTS <br />OI TTS AND <br />IONS ° <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION i <br />STUCCO PROVIDE STUCCO SCRATCH Al <br />COAT LARGER THAN THE ELEC. <br />WOOD SHEATHING ® METER CAN OR METER CAN <br />COMBO OR METER CAN AND NO 9340 <br />SELF-ADHESIVE FLASHING — — — — — DISCONNECT STEP *5 STEP #6 <br />NOTE: Dw � 07/27/20 <br />METAL LATH: LATH TO BE PER SECTION ELECTRICAL CONDUIT O ELECTRICAL RECEPTACLE BCAL.E i/ /27/ 0„ <br />R'103.1.1 /ASTM C-84'1-09, MIN. 2.5 LBS. O PENETRATION ems' <br />PER SQ. YARD (UTILITY OR NOMINAL Yd A� <br />LATH DOES NOT MEET SPECIFICATIONS) Wl� <br />