My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35668 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35668 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:40:09 AM
Creation date
2/19/2025 12:28:00 PM
Metadata
Fields
Template:
Building Plans
Street #
35668
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
750
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603, <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SMALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(20111 MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6T14 <br />EDITION (20M) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER 5006TER TO BE A FANTECH POP BOOSTER FAN OR EQUAL. <br />FANTEC4 DBF 110 DRYER 6006TER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE= <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />SECURE <br />STRAP <br />PLENUM <br />y <br />TO CONC. CONDENSER <br />AIR RETURN W/ eV-3/I6'XV TAPCONS UNIT SIMP80N WB ROLL STRAP <br />OR EQUAL <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />AIR HANDLER <br />y <br />SECURE STRAP TO UNIT W/ (Z) <br />4' CONCRETE SLAB "BXI I/4' SHT. MTL. SCREWS <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER UNIT <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />CONNECTION TO PAD <br />T <br />REPRIGERANTLINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />TRAP DRAIN LINE AND TERMINATE <br />OVER HEAD • 12' FROM STRUCTURE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL ELM CODE <br />SECTION 301Z.4 <br />HVAC <br />DRAINS <br />Elo: <br />SCORIATED NICKEL /—FIN. FLOOR COUNTERSUNK- <br />BRONZE FL. PL. / OR WALL CA. PLUG <br />BRASS PLUG <br />SEE SPEC. <br />1'-8'X8' CONC. <br />I I FIN. GRADE <br />FITTING OR EXTENSION TO OR PAVING' <br />SOIL OR WASTE AS FITTING OR <br />REQUIRED EXTENSION TO SOIL <br />WADE 8240-K JOSAM 56000 OR WASTE AS <br />INSIDE SERIES NICKEL BRASS TOP REQUIRED <br />CAULK P.v.0 OPTI/SPEC <br />INV. E <br />817E PLAN INv. SE <br />ITE PLAN <br />OFLOOR SLAB CLEAN -OUT (T� DEXT. GROUND CLEAN -OUT (TYPE <br />MECHANICAL PLAN <br />SCALE: 1/4 . 1'-0' <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD,FL327W <br />PH: 407-7746078 <br />FAX: 407-174-4078 <br />www.abdesigngroup.com <br />AA 8: 0003325 <br />a <br />P <br />as <br />SUDDIV. at L07il <br />SILVERADO <br />LOT #48 <br />BLK #18 <br />PROJECT <br />04128.00 —48181 <br />MODEL- <br />4EAB <br />"1672—ARIA" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 H E . B <br />9 <br />bwTa: 07/27/20 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.