My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35676 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35676 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:53:37 PM
Creation date
2/19/2025 12:03:25 PM
Metadata
Fields
Template:
Building Plans
Street #
35676
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
751
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MPG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER MC 61I4 EDITION (2011) MECHANICAL BLOC. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS 1 AIR DUCT AS PER NPPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET. OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (20M) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603U <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL. HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND MC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 60'1, <br />W. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH POP BOOSTER FAN OR EQUAL. <br />FANTECH OBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING WIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL SLOG. CODE <br />SECTION 301.2A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL PIK FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />—'�---FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTVSPEC <br />nFL00R SLAB CLEAN -OUT (TY�P, <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRINK <br />— <br />BROKEN LINE. RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OW <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 1 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3A(P')Y' TAPCONS WIT SIMPSON WS ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO WIT l2J <br />"8Xi I/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' OIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSINK <br />CA. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />vEXT. GROUND CLEAN -OUT (TY <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE P.P.E. ELEVATION <br />MECHANICAL PLAN <br />SCALE. 1/4 • P-0' <br />:ml <br />1441 N. RONALD REAGAN BLVD, <br />LONGWOOD, FL 32750 <br />PH: 407-774b078 <br />FAX: 407-7744078 <br />www.abdnigngroup.00m <br />AA N: 0003325 <br />64 <br />rz <br />d <br />Stimm ae L'otil <br />SILVERADO <br />LOT #49 <br />BLK #18 <br />PROJECT <br />04128.001-49181 <br />MODRU <br />4EAB <br />"1672-ARIA" <br />GARAGE 8WDIG: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />I <br />DATE. 07/27/20 <br />SCALE: 1/4--r-0- <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.