My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35690 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35690 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:58:53 PM
Creation date
2/19/2025 12:19:00 PM
Metadata
Fields
Template:
Building Plans
Street #
35690
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
745
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL BEAMS SHALL BE SEALED WITH GLASS FAB t MASTIC. AND <br />INSTALLED AS PER F 5C 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 674 EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />1.. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOM$, 814ALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL. AIR EXHAUSTED. <br />5. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO I"M RECOMMENDATION$ AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11, DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRUING <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 7 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. CONDENSER <br />ATTIC <br />W/ (2)-3/6'X2' TAF'CONS UNIT <br />81MPSON WD ROLL STRAP <br />OR EQUAL <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />4' CONCRETE SLAB <br />SECURE STRAP TO UNIT W/ <br />#SXl 1/4' $HT. MTL. $CREWS <br />(2) <br />SUCTION AND LIQUID <br />AIRSUPPL.Y <br />y <br />PEP IGERANT LINES <br />CONDENSER <br />UNIT <br />AIR HANDLER <br />y <br />CONNECTION <br />TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE, MAIN COND. DRAIN 3/4, DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW BLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP ORAN LINE AND TERMINATE <br />N AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN. FLOOR <br />OR WALL <br />O.INK <br />CIO.PUG; <br />GA. PLUG <br />BEE SPEC. <br />BRASS PLUG <br />�—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE $240-K J08AM 960M <br />INSIDE SERIES NICKEL BRA86 TOP <br />CAULK P,V.0 OPTI/BPEC <br />FLOOR SLAB CLEAN -OUT (,TYR.) <br />FIN. GRADE <br />OR PAVING <br />1'-8•X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />DEXT. GROUND CLEAN -OUT (TYP. <br />MECHANICAL PLAN <br />SCALE, 1/4 - I'-V <br />NOTE, <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION <br />/i <br />1441 N. RONALD REAGAN SWD <br />LONGWOOD, FL 82750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdeslgngmup.com <br />AA #: 0003325 <br />lWi <br />a <br />c <br />1 <br />b <br />ar�ro <br />6 <br />aUDDIV. at LOT: <br />SILVERADO <br />LOT #50 <br />BLK #18 <br />PROJECT <br />04128.001-50181 <br />MODEIi <br />4EBB <br />"1828-CALI" <br />GARAGE 0111ING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />