My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35698 Burma Reed Dr
Zephyrhills
>
Building Department
>
Building Plans
>
35698 Burma Reed Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:05:19 PM
Creation date
2/19/2025 12:14:00 PM
Metadata
Fields
Template:
Building Plans
Street #
35698
Location
Burma Reed Dr
Contractor
DR Horton
Building Plans - Permit #
749
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
39'-8" <br />28'-8" <br />-4" <br />9'-8" <br />9'-6" <br />15'_10" <br />3'4" <br />--FM-12X12 <br />1 <br />FM_12X784"CONC. <br />SLAB4_3112-24X2410FM12X18 <br />I--FXTENFD <br />1.1 <br />SLAB 1 1/2' <br />I <br />• I <br />I <br />1 <br />1.1 I <br />TOP OF <br />I <br />SLAB <br />5 <br />r` <br />. <br />I <br />I <br />I <br />�I <br />I <br />I <br />• I� <br />I• <br />I <br />I� <br />I <br />�I <br />I <br />I <br />I� <br />I <br />15'-8' <br />I <br />4" PVC <br />1 <br />o <br />HASE <br />1.1 <br />TE4 <br />— <br />*-5 112 <br />I 412-8 <br />17-8 <br />-_ <br />5 X-0„ <br />I <br />I <br />I <br />s <br />I <br />I <br />y <br />LLI <br />. i <br />1 <br />EXTEND <br />',' <br />SLAB 1 1/2" <br />2 <br />14 CONC. �I m FM-12X18 <br />m <br />1.1 <br />I <br />I SLAB a wl <br />.. <br />I ' <br />• I <br />I A,-3 1/2 03 al <br />L----1 <br />*7 112 <br />1 <br />1.1 <br />L <br />1.1 <br />FM-12 _ <br />0 <br />F -12X18 <br />FM-12X18 <br />FMC-12X18 <br />4 <br />4 <br />1.1 <br />1.1 <br />10'-2" 3'-10" <br />2'-8" <br />16'_0" <br />2'-8" <br />21'4" <br />14'-0" 4'4" <br />39'-B" <br />3 <br />VIE IV <br />FOUNDATION PLAN <br />SCALE: 1/4" = 1'-0" <br />FOUNDATION NOTES <br />1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR <br />COMPACTING REQUIREMENTS. <br />2. TOP OF FINISHED SLAB SHALL BE +4-0". <br />3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED <br />OTHERWISE. <br />4. REFERENCE ELEVATION +-0'.0", SEE SURVEY PLOT FOR NAVD. <br />5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES. <br />6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: <br />PROVIDE 112" FELT PAPER AT THE JOINT. <br />7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL <br />DRAWINGS, <br />8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. <br />9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE <br />WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS <br />AND WITH THE MANUFACTURES SPECIFICATIONS. <br />10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. <br />11.13INDICATED #5 BAR, MINDICATES #6 BARANDICATES #7 BAR VERTICAL <br />REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE <br />HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 90" <br />HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. <br />12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = <br />30', #6 =36"), AND REINFORCING SHALL BE CONTINUOUS. <br />13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL <br />REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE <br />SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS <br />BEEN DELETED UNLESS NOTED OTHERWISE. <br />14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS <br />OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: <br />A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION <br />C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS <br />15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I. 53D-13/ASCE 5.13, BUILDING <br />CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. <br />CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530.13/ASCE 5.13, USING: Pm = <br />1,500 PSI, TYPE "M" OR'S' MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN <br />RUNNING BOND. <br />16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER } OF SLAB SUPPORTED <br />Y-0" O/C MAX. SEE PLAN FOR W WM SIZE. <br />INSPECTOR NOTE: <br />1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING <br />CODE, RESIDENTIAL, 6th EDITION <br />SLAB SCHEDULE <br />SLAB <br />THICKNESS <br />I REINF, <br />REMARKS <br />6x6 W1.4xW1.4 OVER <br />GENERAL <br />3 1/2" <br />6 MIL VAPOR <br />COMPACTED FILL <br />BARRIER <br />FOOTING SCHEDULE <br />PROVIDE CORNER BARS SAME SIZE QUANTITY AS BARS IN FOUNDATION WITH 30" LEG EACH WAY. <br />MARK <br />I WIDTH <br />LENGTH <br />THICKNESS <br />BOTTOM REINF. <br />TOP REINF. <br />T.O.F. <br />SHORT <br />LONG <br />FM-12x12 <br />12" <br />CONTINUOUS <br />12" <br />- <br />s <br />FM-12x18 <br />IT <br />CONTINUOUS <br />18" <br />FM-16x18 <br />16" <br />CONTINUOUS <br />18" <br />- <br />s <br />FMC-12x18 <br />12" <br />CONTINUOUS <br />18" <br />- <br />s <br />VARIES <br />24" <br />s <br />(-)0"4„ <br />1441 N. RONALD REAGAN 81. <br />LONGWOOD, FL32750 <br />PH: 407-77"078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />L AA #: 0003325 <br />L4 <br />Z <br />6 <br />1 <br />gbg <br />6 <br />o <br />a <br />SUDDM Ae LoT: <br />SILVERADO <br />LOT #51 <br />BLK #18 <br />PROJECT/1 <br />04128.002-51181 <br />MODEL: <br />4EBB <br />"1828—CALY" <br />GAMAWOM 8WING: <br />RIGHT <br />PAGE: <br />FOUNDATION <br />PLAN <br />150 MPH EXP. B <br />D TE 07/27/20 <br />8CALE: 1/4"=1'-0" <br />8HEET <br />S1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.