A{1) SIMPSON HETA16 TRUSS ANCHOR WITH
<br />(9) 10d x 1 }'NAILS TO TRUSS
<br />B{2) SIMPSON HETA16 TRUSS ANCHOR WITH
<br />(12) 16d x i }" NAILS TO TRUSS
<br />DBL STRAP, 1 EACH SIDE WRAPS UP AND
<br />OVER TRUSS (NOT SHOWN)
<br />C-(I) SIMPSON LGT2 GIRDER TIEDOWN WITH
<br />(16) 10d x 3 }" NAILS TO GIRDER AND
<br />(2) SIMPSON HETA16 TRUSS ANCHORS
<br />WITH (12)16d x 3 }" NAILS TO GIRDER
<br />,x2, 2x WOOD FASCIA
<br />SEE ARCHITECTURAL
<br />1x SECURED W/ (3)16d
<br />GALV. COMMON NAILS.
<br />1x2 SECURED W/ 10d
<br />GALV. COMMON NAILS
<br />12"O/C
<br />MASONRY BOND BEAM
<br />SEE SCHEDULE
<br />PLYWOOD SHEATHING, SEE
<br />"ROOFNVALLIFLOOR
<br />SHEATHING
<br />FASTENER SCHEDULE"
<br />NOTE: APT SYP #22"x4",
<br />6', 8" x 4'-0" MAY BE ADDED
<br />W/ 10d NAILS, 2 ROWS, 3"
<br />OIC TO FACILITATE ONE
<br />ADDITIONAL PLY MAX. TO
<br />ACCOMMODATE TRUSS
<br />ANCHOR REQUIREMENTS.
<br />ENGINEERED WOOD
<br />TRUSSES 0 24" O/C,
<br />SUBMIT SHOP DRAWINGS
<br />FOR REVIEW
<br />AND APPROVAL
<br />A ALLOWABLE UPLIFT = U:1810 LBS, L:770 LBS (1 PLY)
<br />B ALLOWABLE UPLIFT = U:2365 LBS, L:1430 LBS (2 OR 3 PLY)
<br />C ALLOWABLE UPLIFT = U:2705 LBS (2 PLY)
<br />88S-GOR-DERPICAL T
<br />RUSS/
<br />USS/ CONNECTORS)
<br />314" T 6 G SUBFLOOR GLUED AND
<br />SCREWED AS PER SCHEDULE
<br />I- YP
<br />PRE-ENG FLOOR TRUSS
<br />5/8" GSUM BOARD OR 1/2" HIGH
<br />STRENGTH CLG. BOARD
<br />SECURE TRUSS TO TOP PLATE w/ (2)
<br />16d TOENAILS
<br />DOUBLE TOP PLATE
<br />2X4 OR 2x6 WOOD BEARING
<br />WALL W/ SYP No 2 STUDS SEE
<br />PLANS FOR SPACING. SINGLE
<br />BTM. PLATE TO BE PT.
<br />PROVIDE DBL. TOP PLATE
<br />PROVIDE BLOCKING
<br />1/2" GYP. WL. BO.
<br />FLOOR TRUSS CONNECTION @ L.B.W.
<br />y' SCALE: 3/4"=V-0"
<br />(NO UPLIFT)
<br />NOTCH DEPTH 1/4"D
<br />HOLE EDGE >5I8"
<br />OLE DIAMETER
<br />< 2/5"0 SGL. STUD
<br />OUTER 113 OF
<br />SPAN ONLY
<br />HOLE EDGE >50
<br />BTM. -
<br />PLATE
<br />STUD NOTCHING
<br />AND BORING LIMITS
<br />i?
<br />SCALE: 1 1/2"=1'-0"
<br />HOLE DIAMETER
<br />< 3/5"D DBL. STUD
<br />ENGINEERED WOOD TRL
<br />0 24" O/C, SUBMIT SHOP
<br />DRAWINGS FOR REVIEW
<br />AND APPROVAL
<br />(1) SIMPSON HETA16 -�
<br />TRUSS ANCHOR WITH
<br />(9) iOd x 1 }" NAILS TO
<br />GIRDER. PROVIDE 5"
<br />MINIMUM CONCRETE
<br />EMBEDMENT. USED IN
<br />CONJUNCTION WITH
<br />HEAVY UPLIFT
<br />CONNECTOR
<br />SE 2x WOOD FASCIA -'
<br />SEE ARCHITECTURAL
<br />2x SECURED WI (3)16d
<br />GALV. COMMON NAILS. MASONRY BOND
<br />lx2 SECURED W/ 10d
<br />GALV. COMMON NAILS BEAM
<br />12"O/C SEE SCHEDULE
<br />PLYWOOD SHEATHING, SEE
<br />"ROOF/WALUFLOOR
<br />SHEATHING
<br />FASTENER SCHEDULE"
<br />NOTE: A PT SYP #2 2" x 4",
<br />6", 8" x 4'-0" MAY BE ADDED
<br />W/ 10d NAILS, 2 ROWS, 3"
<br />O/C TO FACILITATE ONE
<br />ADDITIONAL PLY MAX. TO
<br />ACCOMMODATE GIRDER
<br />TIEDOWN REQUIREMENTS.
<br />A-(1) SIMPSON LGT3SDS2.5 GIRDER TIEDOWN
<br />WITH (4) r x 5" TITEN HD TO CMU AND (12) SOS
<br />k x 2 }" TO GIRDER
<br />B-(1) SIMPSON FGTR GIRDER TIEDOWN WITH
<br />(2) J" x 5" TITEN HD TO CMU AND (18) SOS }'x
<br />3" TO GIRDER
<br />C42) SIMPSON FGTR GIRDER TIEDOWNS WITH
<br />(2) �' x 5-TITEN HD TO CMU AND (18) SDS }" x 3"
<br />SCREWS TO GIRDER (EACH TIEDOWN)
<br />ENSURE THAT CELLS ARE GROUTED
<br />SOLID, 8" EACH WAY OF BOLTS
<br />A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY)
<br />B ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.)
<br />C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.)
<br />2A 2B 2C TYPICAL ROOF
<br />GIRDER CONNECTOR(S)
<br />LSTA12 20 GAUGE
<br />W/ 1 OW12 HOG NAILS
<br />0 EACH END. TOTAL OF 10
<br />FLOOR
<br />GIRDER
<br />HTT4 W/ 518" A.S. WITH
<br />MIN, 7" EMBEDMENT
<br />TO SLAB 8 (18)16d x
<br />2-12" NAILS TO POST.,
<br />POST TO SIT DIRECTLY
<br />ON SLAB ---
<br />.d .
<br />GIRDERIWOOD POST CONNECTIONS
<br />5 SCALE: 3/4'=1'-0°
<br />A - SIMPSON HUS28 G < 1200 LBS, U < 1280 LBS WI (1) 3/4^ SIMPSON TITEN BOLT/J-BOLT, 5" MIN.
<br />EMBED (22)16d GALV. COMMON NAILS AND (8) 16d GALV. COMMON NAILS.
<br />B - SIMPSON HUS28 G < 2400 LBS, U < 1425 LBS W/ (2) 3/4"° SIMPSON TITEN BOLT/J-BOLT, 5" MIN.
<br />EMBED (22)16d GALV. COMMON NAILS AND (10)16d GALV. COMMON NAILS.
<br />C - SIMPSON HGUS28-2 G < 24DO LBS, U < 1810 LBS W/ (2) 3/4"" SIMPSON TITEN BOLT/J-BOLT, 5"
<br />MIN. EMBED (38)16d GALV. COMMON NAILS AND (12) , 6d GALV, COMMON NAILS.
<br />0 - SIMPSON HGUS28-2 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4"" SIMPSON TITEN BOLT/J-BOLT, 5"
<br />MIN. EMBED (36)16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS.
<br />E - SIMPSON HGUS283 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4"" SIMPSON TITEN BOLT/J-BOLT, 5"
<br />MIN. EMBED (36)16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS.
<br />WOOD LEDGER
<br />9 ATTACHMENT DETAIL
<br />SCALE: 3/4"=V-0"
<br />6'-W MAX (W/1X4)
<br />OR 10'-0" MAX (W/2X4)
<br /># 1100 UPLIFT SIMPSON -
<br />HTSM20 W/10 10d TO
<br />TRUSS AND (4)114" x 2 114"
<br />TITEN 2 ANCHORS TO
<br />CONT POURED LINTEL
<br /># 19W UPLIFT (2) SIMPSON
<br />HTSM20 INSTALLED ON
<br />OPPOSITE FACES OF
<br />BLOCK WALL W/1010d TO
<br />TRUSS AND (4)1/4" x 2 1/4"
<br />TITEN 2 ANCHORS TO
<br />CONT POURED LINTEL
<br />PRE-ENG TRUSS
<br />CONTINUOUS BOND BEAM
<br />TITEN 2 ANCHORS MIN.
<br />2" COVER 8 2" APART
<br />REPAIR OF MULTIPLE
<br />3 MISPLACED EMBEDDED TRUSS ANCHOR
<br />SCALE: 3/4'=1'-0"
<br />(2) 2X4 No.2 SYP DIAG. -
<br />BRACE W/ (3)12d Q EA.
<br />TRUSS (DIAG. BRACE TO
<br />COVER 5 TRUSSES)
<br />0'4" TO 30'-0" (1) "X" BRACE
<br />30'-1" TO 601-0 (3) "X" BRACE
<br />(1) "X" BRACE C CENTER
<br />(2) "X" BRACE DIVIDED EQUALLY
<br />FROM CENTER TO END.
<br />2x WOOD FASCIA, -
<br />SEE ARCHITECTURAL
<br />lx4 DIAGONAL
<br />PRE-ENG GABLE TRUSS —�
<br />BTM. CHORD
<br />BRACING, SEE
<br />STIFFBACK (AS PER—�
<br />PLAN FOR LOCATION
<br />TRUSS ENG)
<br />MAY NOT BE
<br />REQUIRED
<br />BTM. CHORD OF
<br />WOOD ROOF TRUSSES
<br />1x4 BTM. CHORD BRACING 6'-0" O/C —/ --END WALL OR OTHER
<br />MAX., OR 20 BTM. CHORD BRACING END TYPE CONDITION, IF
<br />10'-0- O/C MAXSECURED W/ (2) lod DEPICTED SEE PLAN
<br />COMMON NAILS AT EACH CHORD
<br />INTERSECTION TYP. BTM. CHORD BRACING
<br />6
<br />5'EDGE
<br />CENTRAL
<br />SPACING
<br />SPACING
<br />SEE
<br />SEE
<br />�CHEDULE,
<br />SCHEDULE AMIN LAN
<br />All
<br />SEE SCHEDULE FOR BOLT SIZE
<br />SEE LEDGER SCHEDULE
<br />51/2" MIN. EMBED. (TYP)
<br />1. ENSURE THAT EXP. BOLTS/J-BOLTS ARE
<br />PLACED INTO GROUTED CELLS, 8" ALL AROUND
<br />BOLT.
<br />- Z
<br />2. END OF FRONT AND REAR LEDGER SHOULD
<br />LAP A MIN OF 4'-0".
<br />3. ALL BOLTS TO HAVE WASHERS
<br />Z
<br />4. EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY
<br />CLOSER THAN 6" O/C.
<br />5. IN LIEU OF HILTI PAPS SIMPSON TITEN 114"
<br />(2)- PT
<br />DIA. x 3" MASONRY SCREWS MAY BE USED,
<br />exx.c co 1—o—H.—MT
<br />LEDGER SCHEDULE
<br />MARK
<br />SIZE
<br />BOLTSIZE
<br />FEDGESPACING
<br />CENTRN.BPACING
<br />A
<br />DOUBLE 2x8
<br />12"
<br />8" O/C
<br />I V, O/C
<br />B
<br />DOUBLE 2X8
<br />3/4"
<br />8" O/C
<br />24" O/C
<br />C
<br />DOUBLE 2x10
<br />12"
<br />8" O/C
<br />16" OIC
<br />D
<br />DOUBLE 2XIo
<br />3/4"
<br />8" O/C
<br />24" O/C
<br />E
<br />DOUBLE 2x10
<br />3/4"
<br />6" O/C
<br />16" OIC
<br />F
<br />DOUBLE 2x12
<br />1 3/4"
<br />1 6" O/C
<br />1 12" OIC
<br />S'-,�4OOD LEDGER DETAIL
<br />SCALE: 3/4"=V-0"
<br />SEE SCHEDULE FOR
<br />BOND BEAM REQ.
<br />2X4 BLOCKING BETWEEN
<br />TRUSSES WHERE
<br />X-BRACING IS PRESENT AT
<br />4'-0" O.C. (AT SHEATHING
<br />SEAMS)
<br />SECURE 2x8 PT. PLATE
<br />TO BLK W/ 1/2" DIA,
<br />ANCHOR BOLT W/ Y'
<br />WASHER SET IN HIGH
<br />STRENGTH EPDXY 6"
<br />MIN. EMBED. AT 32" OC
<br />MAX.
<br />SECURE GABLE TO 2X8
<br />P.T. PLATE W/ 12d's 8"
<br />O.C. MAX
<br />CONT. 2x4 SECURED W/
<br />(2)1 Od's @ EACH TRUSS
<br />TO BE INSTALLED Q
<br />10'-W O.C, MAX.
<br />BLOCK WALL W/ GABLE END
<br />PRE-ENG'D TRUSS SCALE: 3/4-=T:
<br />THE USE OF ALTERNATE MATERIALS MAY BE
<br />USED SO LONG AS THEY CONFORM TO THE
<br />FOLLOWING
<br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS
<br />A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS
<br />EQUIVALENT OR GREATER UPLIFT AND LATERAL (Fi AND F2) LOAD CAPACITIES
<br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND
<br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE
<br />THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO
<br />A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2
<br />FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE
<br />SUBJECT TO FI AND F2 FORCES.
<br />11 ALTERNATE MATERIALS
<br />SCALE: 3/4"=1'4'
<br />1441 N. RONALD REAGAN BLVD.
<br />ORLANDO,FL32750
<br />PH: 407-774$078
<br />FAX: 407-774-4078
<br />www,abdosigngroup.com
<br />AA #: 0003325
<br />DRAFTING BY:
<br />A.B. DESIGN GROUP
<br />DRAFTING INC.
<br />5438 BEAUMONT CENTER BLVD.
<br />SUITE 1004
<br />TAMPA, FLORIDA 33634
<br />PH: 813486.2628
<br />FAX: 813888.2802
<br />�INIIIIIII
<br />91111111113
<br />�vo
<br />aoo
<br />,
<br />BUDDIV. A# JOT:
<br />SILVERADO
<br />LOT #4
<br />BLK #13
<br />Pmj=T/
<br />03719.000-04131
<br />MODE A
<br />2795- B
<br />GARAGE OWING:
<br />LEFT
<br />PAGE:
<br />DETAILS
<br />%150 MPH EXP. B
<br />
|