Laserfiche WebLink
■- <br />HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS OWALL BE CONSTRICTED OF A VALUE <br />OF NO LESS THEN R-6 RATINGG, ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FOC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 161 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALLNat BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT CUTLET <br />S. ALL EXHAAIBT AND OUTSIDE AIR INLET DUCTS, STALL DE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER PBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />1. 15ATWROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8 ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO dE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILING AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECt"IENDATIONB AND MC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DDF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETUPIN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR ODD <br />(� <br />CEILING EXHAUST FAN <br />RCEILING <br />EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />m <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />- <br />PANS W/ DRAINS <br />ATTIC <br />SECURE STRAP TO CONC. <br />CONDENSER <br />CEILING <br />EXTERIOR WALL <br />W/ (2)-3/I6'X2' TAPCONS <br />UNIT <br />SIMPSON WB ROLL STRAP <br />O <br />O <br />OR EQUAL <br />PLENUMAUMECWANICAL <br />AIR RETURNON <br />AND LIQUIDAIR <br />SUPPLYGERANT <br />LINES <br />4'CONCRETE SLAB SECURE STRAP 70 UNIT W/ (2) <br />#BXI i/4• BHT. MTL. SCREWSAIR <br />HANDLERCONDENSER <br />UNITRIOR <br />WALLVC <br />CONDENSATE DRAIN LINE <br />CONNECTION TO PADEVAP.TRAYLEEVE <br />TO LINES BELOW SLABNOTES <br />MAIN COND. DRAIN 3/4'DIA <br />REFRIGERANT LINES TO <br />OVER HEAD • 12' FROM STRICTURE <br />PLATFORMCONDENSING <br />UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVEp DRAIN, AS PER <br />POOR 6TH EDITION (2011) <br />SLOG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRA88 PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 560M <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V): OPTI/BPEC <br />(I)FLOOR SLAB CLEAN -OUT (TYPN <br />COUNTERSUNK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-8'X8CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />TS <br />gEXT. GROUND CLEAN -OUT (TYPN ) <br />MECHANICAL PLAN <br />SCALE. 1/4 • I'-0' <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-774.4078 <br />www.abdosigngroup.com <br />AA A: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5438 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 8138B8-2828 <br />FAX: 813-088-2802 <br />SILVERADO <br />LOT #4 <br />BlK #13 <br />PROJmCT* <br />03719.000-04131 <br />MODZU <br />2795- B <br />GAP-AMs 8WINCs: <br />LEFT <br />PACE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />t� <br />aw 6/11120 <br />SICAta: 1/4"=l'-O" <br />wmxmT <br />M1 <br />