My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35821 Iron Redding Ct
Zephyrhills
>
Building Department
>
Building Plans
>
35821 Iron Redding Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:19:20 PM
Creation date
2/19/2025 12:02:45 PM
Metadata
Fields
Template:
Building Plans
Street #
35821
Location
Iron Redding Ct
Contractor
DR Horton
Building Plans - Permit #
1068
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DAGGER ROD <br />BACKER ROD <br />URS LAYER -1, <br />STUCCO WRAP <br />INSTALL W SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEryaN-r OF FLASWWS TO BE, <br />L BOTTOM. 2. SIDES. 3. TOP <br />VENT GAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO 15E <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z DEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Y4 CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />E,Genor k>hlnG arw p1wila ing <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />HOODED VENT <br />PLA,S R3 COAT CEMENT <br />METAL LATH <br />UFO LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT (FRAME) <br />WOOD SHEATHING <br />WRB LAYER -1, <br />STUCCO WRAP <br />URD LAYER 4, PORTIFIBER <br />BUILDING PAPER <br />WOOD — <br />CONSTUCTION <br />—FETAL LATH <br />a' cm VINYL CASING BEAD <br />W RAISED SAND <br />VT VM9_- L <br />6' WIDE STRIP SELF <br />ADHESIVE FLA664ING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z PLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-0% MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT <br />TOP 4 SIDES <br />GB DRYER VENT (BLOCK) <br />BUILDNG PAPEF <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />6' SELF ADHESI1 <br />FLASHING (NSTA <br />PER MANUP. VIE <br />BUILDING PAPS! <br />UNDER 'QUICK FI <br />A VENT PENETRATION <br />SCALE. N.T.S. <br />ELEC. METER FIELD-1 " <br />VERIFY LOCATION / `ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER02, FORTIFIBER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />Y6' TO Yo' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />_L p' I ; WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME TO FRAME <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-C'GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />AREA TO RECEIVE — <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATH(( <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAI <br />EDGE <br />APPLY E-Z <br />OVER 6® MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />NTERSECTIC <br />WOOD SHEATHING <br />,411111110, LAYER 51, <br />STUCCO URAP <br />LAYER Q, FORTIFI15ER <br />BUILDING PAPER <br />METAL LATH <br />WOOD -I/O'TEXTUIWW <br />CONSTIBIGTION FINI864 <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER a T' O.C. MAX <br />6, CMU i <br />W To 1S• MO -WALL <br />WEEP aCllEED <br />6' IUDE STRIP SELF <br />?' ADI-IRSIVE FLASHING, CLEAN <br />MASONRY BEFOW APPLYING <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK <br />e' <br />WRB LAYER N, <br />STUCCO WRAP <br />4(777 <br />GUT 'X' INTO <br />SELF -ADHERING <br />I <br />MEMBRANE FLASHING <br />APPLY SELF-AD14ERNG <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WFB LAYER <br />STEP #I <br />STEP 02 <br />WRB LAYER 7, <br />STUCCO WRAP <br />APPLY 6d7 MN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP #3 <br />® {MEMBRANE FLASHING I <br />`WM LAYER'2, FORTIFISER <br />5UILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />ti METAL LATH <br />STEP *5 STEP #& <br />@)ELECTRICAL RECEPTACLE <br />A R 9 N I T E 9 T 1 <br />GrOU Design <br />a 1 R. nvnnw ecrr N ewu. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abd"gngroup.com <br />64 AA N: 0003325 <br />III DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813.888.2628 <br />FAX: 813E8&2802 <br />SVHDIN. Ae LOT: <br />SILVERADO <br />LOT #12 <br />BLK #13 <br />PROJECT# <br />03719.000-12131 <br />MODEL• <br />2795—F <br />GARAGE STIMG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP B <br />R <br />7/07: 1/4"=1'-O" <br />A2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.