Laserfiche WebLink
BACKER ROD <br />BACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEhJENCE OF FLASHING TO BE, <br />L BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO SE <br />TOOLED 80 AS TO DEFLECT <br />WATER AWAY FROM JOINTS, <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Yi CAULKING 1 JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Exteror Wftrlg end Dlaeleft <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior Lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER 9, <br />STUCCO WRAP <br />t..X_ <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />;. <br />PLASTER <br />METAL LATH <br />WRB LAYER 4, FORTIF15ER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />WOOD SHEATHNG <br />WRB LAYER % <br />STUCCO WRAP <br />UIi6 LAYER 4, FORTPIBER <br />BUILDING PAPER <br />WOOD — <br />CONBTUCTION <br />'—METAYL L LATH <br />v CHU VINCAMG SBEAD <br />W RAISED BAND <br />x• ro14• •,IO_°� L <br />uIEEP erieEeD <br />61 WIDE STRIP ew <br />ADHESIVE FLABHMG, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKZ <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — ------- <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-09, MIN. 2.5 LBS. <br />PER 80. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELEC. METEI <br />VERIFY LC <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP t SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF- DRYER <br />VENT GAP (SET IN <br />CONT. SEALANT) <br />SEALANT <br />TOP 4 SIDES <br />(9 DRYER VENT (BLOCK) <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER M, <br />STUCCO WRAP <br />WRB LAYER "2, FORTIP15ER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />Ye' TO Ys' MID -WALL <br />WEEP SCREED <br />�6' SELF-ADHESIVE <br />FLASHING <br />BUILDING PAPER <br />OVER *0JICK WOOD FRAMED <br />FLASH' r — — — —j WALL <br />HORIZONTAL WEEP SCREED <br />PIPE THROUGH WALL (FRAME TO FRAME) <br />1 <br />6' SELF ADHESIVE <br />FLASHING (INSTAL.L <br />PER MANJF. SPECS.) <br />BUILDING PAPER <br />UNDER 'I Upl FLASH' <br />A VENT PENETRATION <br />SCALE, N.TS- <br />NF�K IV ICCC.CIVG <br />STUCCO SCRATCH COAT <br />e 1 COAT OF PAINT W/BAGK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING N <br />APPROVED WOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEUIRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX <br />APPLY TO FAA <br />EDGE <br />APPLY E-Z <br />OVER 6® MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT Al <br />JOINTS AND <br />INTERSECTIG <br />STEP 01 <br />STEP 03 <br />WOOD <br />CONSTRUCTION <br />v Cm <br />WOOD SHEATHNG <br />ORB LAYER -I, <br />STUCCO WRAP <br />WRB LAYER 9, FORTIFISER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRllCTIRAL <br />MEMBER -'I' Or MAX <br />WvTO niD-WAIL <br />®� sOEm <br />ADHESIVE PL.AeHING, CLEAN <br />MASOSW BEFOM APM_YMG <br />V FMMN • MASOWT <br />(�oHORIZONTAL WEEP SCREED <br />FRAME TO BLOCK) <br />S' <br />WRB LAYER 01, <br />STUCCO WRAP <br />CUT 'X' INTO <br />.. <br />SELF-AD14ERNG <br />MEMBRANE FLASHING <br />f 1 <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />STEP <br />12 <br />WRB LAYER "I, <br />STUCCO WRAP <br />APPLY 60 MIN <br />SEMBRANE INGS <br />GRADE 'D' FELT <br />® <br />MEMBRANE FLASHIIJCr <br />FLA <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WR6 LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />STEP <br />1*4. <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.v. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP *5 STEP #6 <br />OELECTRICAL RECEPTACLE <br />AECEITET3 <br />6 <br />ign <br />I. <br />i"I N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />wwwabdeslgngroup.com <br />AA N: 0003325 <br />I <br />tt <br />0 <br />FS <br />V <br />z <br />C <br />X"=ZV. dI LOT. El <br />SILVERADO <br />LOT #11 <br />BLK #13 <br />PROdfICT# <br />03719.000-11132 <br />MOD=& <br />2045—UNTANA7 <br />OARAGM sW11141 - <br />RIGHT <br />PAGE <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />A <br />E8/17/vo <br />1/4"=1'-0" <br />A2 <br />