My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35841 Iron Redding Ct
Zephyrhills
>
Building Department
>
Building Plans
>
35841 Iron Redding Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:39:22 PM
Creation date
2/19/2025 12:15:51 PM
Metadata
Fields
Template:
Building Plans
Street #
35841
Location
Iron Redding Ct
Contractor
DR Horton
Building Plans - Permit #
1061
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SMALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL DE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER POO 6TH EDITION (20T1) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA SOA 2-3J <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY C 4IMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHNG FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8, ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SMALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOhIMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A PANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRIANC <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR ODD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THM AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />EXTERIOR WALL <br />O __ <br />SECURE STRAP TO CONC. CONDENSER <br />PLENUM <br />y <br />AIR RETURN W/ (2)-3A6'X2' TAPCONS UNIT SIMP60N WB ROLL STRAP <br />OR EQUAL <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />AIR HANDLER____y <br />4' CONCRETE SLAB SECURE 844T. STRAP TO <br />SCREWS l2) <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER UNIT <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />CONNECTION TO PAD <br />? <br />REFRIGERANT LINES TO <br />PLATFOF <br />RETURN <br />CONDENSING UNIT <br />NOTE: MAIN COND. DRAIN 3/4' DIA <br />TRAP DRAIN LINE AND TERMINATE <br />OVER HEAD 12' FROM STRUCTURE <br />IN AN APROVED DRAIN, AS PER <br />POOR 6TH EDITION (2011) <br />MECHANICAL BLCa CODE <br />SECTION 301.2.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR COUNTER&NK <br />BRONZE FL. PL. OR WALL CD. PLUG <br />SEE SPEC. <br />i0 <br />BRASS PLUG I'-8'X6' CONC. <br />I I FIN. GRADE <br />FITTNG OR EXTENSION TO OR PAVING <br />SOIL OR WASTE AS <br />REQUIRED EXTENSION <br />OR <br />EXTENSION TO BOIL <br />WADE 6240-K JOSAM 560M OR WASTE AS <br />INSIDE SERIES NICKEL BRASS TOP REQUIRED <br />CAULK P.V.0 OPTI/SPEC <br />INV. <br />ITE PLAN INV. <br />1 <br />T L00R SLAB CLEAN -OUT (TYPN) NEXT. GROUND CLEAN -OUT (TYPN ) <br />F77- <br />1 U �I 1 <br />MECHANICAL PLAN <br />SCALE: 1/4' . P-O' <br />A R C N I T! C T II <br />6 <br />Groin <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7744078 <br />FAX: 407-774.4078 <br />www.abdeWg"group.com <br />AA 8: 0003325 <br />IF DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 8134186.2628 <br />FAX: 813486.2902 <br />,,W 08/17/20 <br />ECAUL' 1/a"=1'-0" <br />E*MlCT <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.