My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35849 Iron Redding Ct
Zephyrhills
>
Building Department
>
Building Plans
>
35849 Iron Redding Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:51:41 PM
Creation date
2/19/2025 12:13:47 PM
Metadata
Fields
Template:
Building Plans
Street #
35849
Location
Iron Redding Ct
Contractor
DR Horton
Building Plans - Permit #
685
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A R C H I T E C T <br />BACKER ROD <br />BACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(B) AND DOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE E)0HAUST. <br />SECLIENCE OF FLASHING TO BE, <br />I- BOTTOM, 2. SIDES- 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 16 TO BE <br />TOOLED 60 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES,Ys' CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />EXtaft Ia1Mn0 and deBRrlrg <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER 01, <br />STUCCO WRAP <br />I ..: <br />WOODED VENT <br />ej <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />UM LAYER $2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />WOOD — <br />O"TUCTION <br />rL�s. <br />P 6HEATHNG <br />LAYER -1, <br />CO WRAP <br />LAYER 4. FORTIFIBER <br />61 WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING; <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER e2 (FORTIFIBER — — - — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-0% MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />FB DRYER VENT (BLOCK) <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />Ye' TO N.' MID -WALL <br />WEEP SCREED <br />`-6' SELF-ADHESIVE <br />FLASHING <br />BUILDING PAPER WOOD FRAMED <br />OVER 'CIUIC K <br />FLASH' r — — — —I WALL <br />HORIZONTAL WEEP SCREED <br />PIPE rNROUGH (FRAME TO FRAME) <br />WALL <br />I <br />6' SEELP ADHESIVE <br />FLASHING (INSTALL <br />PER MANUP. OPEC$.) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />WALE. NT.S. <br />ELEC. METEF <br />VERIFY LO <br />riRc,+ iv 1cc�.c�vc <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />`ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA' <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAX <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />UIOOD <br />CONSTRICTION <br />mnnkm <br />WOOD 814EATWMG <br />WRB LAYER M, <br />STUCCO WRAP <br />UM LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD GTRICTURAL <br />MEMBER • V = MAX <br />XTO ff' <br />,EEC ar�Esr� <br />6' WDE STRIP SELF <br />ADNENVE PLASHING, CLEAN <br />MASONRT DEPORE APPLYING <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCKI <br />WRB LAYER 01, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRBLAYER <br />STEP #1 <br />APPLY 6C MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />WOUSEWRAP <br />STEP #3 <br />6• <br />STEP *2 <br />WRB LAYER 01, <br />STUCCO WRAP <br />SELF-AG <br />® <br />MEMBRANEFL FLASWING <br />WRB LAYER 02, FFMTIF15ER <br />BUILDING PAPER <br />STEP <br />#4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V, FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP '5 STEP #& <br />OELECTRICAL RECEPTACLE <br />PS <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7744078 <br />FAX: 407-774.4078 <br />www.abd"gngroup.com <br />AA B: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PN: 813886.2628 <br />FAX: 813.886-2602 <br />sUDDrV S. LOT: <br />SILVERADO <br />LOT #9 <br />BLK. #13 <br />MM 00 0—09131 <br />MODM, <br />B <br />GARAGM sWuQO: <br />RIGHT <br />IPA Z: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />
The URL can be used to link to this page
Your browser does not support the video tag.