My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36036 Carriage Pine Ct
Zephyrhills
>
Building Department
>
Building Plans
>
36036 Carriage Pine Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:01:08 PM
Creation date
2/19/2025 12:07:13 PM
Metadata
Fields
Template:
Building Plans
Street #
36036
Location
Carriage Pine Ct
Contractor
DR Horton
Building Plans - Permit #
17927
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br />SYMBOL <br />DEFINITION <br />NOTES <br />_e <br />125V OUTLET <br />20 NIP SFYdE POLE <br />II0V OUTLET <br />II0V <br />CINLM WIREO <br />OUTLET <br />TOO SWITC.1 <br />GPI <br />110V OUTLET <br />SWIPED WR3RID FAH <br />WTERPTER (TAPPER <br />WS'STANT TYPE) <br />220V OUTLET <br />I4) WRffi CONiECTICN <br />r¢1 <br />=L-ET <br />ME MTERRF RT <br />�j <br />9WTC4 <br />SWITCH <br />3-WAY O'ER <br />W4 <br />SWITCH <br />4-WAY OPER <br />�_o <br />M0 o <br />��J <br />L_KaFIT <br />CEILING LIGHT <br />VP <br />VAwroRT PIl�CP <br />\b�) <br />\Q\ <br />RECESSED CNJ <br />�- <br />WALL BGOHCE <br />PAE•WIRED <br />VENT. FAN <br />I OT1 PER 80. FT. <br />VENT. FAH <br />W,LIGHT <br />I CFM PER 80. R. <br />y <br />RITT <br />V PIXIUE <br />rePECa TeD eY <br />eW DER) <br />4'X1' <br />PLuoRESTCEFItLIGH <br />1-BJLB WQAP <br />_ <br />2' FLUORESCENT <br />4' PLUORWCENT <br />W--n--�.,-� <br />4• TRA LIGHT <br />O <br />PANEL <br />NiiiiIIIII <br />METER <br />• S.D. <br />enolaT oEreerae <br />�y <br />W MOUMED <br />e4TT_ edCK-IP <br />5D. <br />sHoOE DETEcroR <br />w-Haaawm <br />eon. eAac-IP uv <br />® S/CO <br />ceuc 4 noxGwoe <br />SHOD D[TEROR <br />Cq.®O <br />SHALL Q A 016T <br />SHALL eE A <br />THEN I' <br />OF NOT LESS THEN 4' <br />FIOOIT L <br />PENDAM LK:xT <br />1 <br />AL 6AS <br />I� <br />l/ <br />CUTLET <br />. <br />TELEPHONE JACK <br />� <br />WATER (EATER <br />DISCONNECT <br />IO xE EL�VAIED <br />I I TV.I I TELEVISION IACK I I <br />CEILING PAWLKlRIACCCrpAHCE W/ e0X <br />�WIRCED AS dCJI FOR <br />FLGGD LK <br />cPr. eEclmTr <br />KEYPAD <br />PIS N-eDTTGN FOR 01F'ES <br />Use PCR <br />JO ES: <br />LOCATION OF TV JACKS 4 PHONE OUTLETS r <br />FANS TO BE VERIFIED a HOMEOWNER <br />PRE -CONSTRICTION MEETING. <br />ALL RECEPTACLES IN ALL HABITABLE <br />ROOMS TO BE ARC FAULT PROTECTED PER <br />ELECTRICAL PROVISIONS OF F15CR 5TH <br />EDITION (2014). <br />20 AMP DEDICATED LAUNDRY CIRCUIT. <br />GFI • ISLAND (NOT ON KITCHEN CIRCUIT) <br />DISHWASHER DISCONNECT TO BE LOCKOUT <br />IN PANEL <br />BATHROOM EXHAUST FAN TO HAVE MIN. <br />CAPACITY OF 50 CFM INTERMITTENT PER <br />ELECTRICAL PROVISIONS OF SECTION <br />M15013 FBCR 5TH EDITION (2014). <br />LAUNDRY ROOM RECEPTACLE SHALL BE <br />GROUND FAULT CIRCUIT -INTERRUPTER <br />PROTECTION FOR PERSONNEL ON FEEDERS <br />WIRNG METHOD SHALL BE NON METALLIC <br />CABLE PER ELECTRICAL PROVISIONS OF <br />FBCR 5TH ED (2014). <br />ALL RECEPTACLES TO BE TAMPER- <br />RESI5TANT TYPE <br />ALL WORK TO COMPLY WITH ELECTRICAL <br />PROVISIONS OF THE FBCR 5TH ED (2014). <br />CONSERVATION (RESIDENTIAL ENERGY <br />EFFICIENCY) 2014. 5th EDITION R404.1 <br />PRE -WIRED <br />CLG FAN <br />BEDROOM #2 \\ <br />CORD. BOLLARD <br />O AS REO. <br />PER BLDG. <br />CODE <br />METER <br />FIELD <br />VERIFY <br />LOG. <br />IRRIGATION <br />OUTLET • <br />48' AFF. <br />NG <br />ooM <br />PRE -WIRED <br />CLG FAN <br />r/ <br />30\\ <br />/ \ SWITCH It <br />CABINET <br />\ <br />TO 2ND FL OUTLET - <br />SWITCH FOR DW <br />II <br />\ <br />I— <br />Tb <br />1 <br />P.B. F <br />GARAGE \ <br />DOOR \ <br />GO <br />1 <br />/ <br />I <br />/ <br />1 <br />KEYLESS <br />M <br />FIXTURE <br />\\ <br />II GFI <br />FOYER \ <br />Ull GARAGE <br />\ <br />DOOR <br />I <br />PREWIRE <br />GARAGE <br />PATIO <br />r <br />GFI �-- <br />II <br />II <br />-c <br />J N w <br />I _ <br />QD <br />I D / I <br />KITCHEN <br />GFI <br />/ — PAN. <br />OFF 7 <br />GF REF - <br />IL_44 L <br />1 <br />\ PRE -WIRED <br />\ CLG FAN <br />\\`_3:� <br />FLEX <br />PB FOR 1 <br />\ CHIMES PORCH <br />I <br />FIRST FLOOR ELECTRICAL PLAN <br />-OUTLET <br />FOR VENT <br />OR MICRO <br />I UNIT - NELU CHART <br />LOAD CALCULATIONS ONE FAMILY <br />DWELLING WITH HEAT PUMP <br />(NEC CCDE'0V <br />HOUSE PLAN:4EHH HAYDEN MODEL <br />LOAD INFORMATION <br />VA <br />2801 SQ FT GENExAL LIGHTDN2 Y 3 VA PBR SQ " <br />T809 <br />2 20 Al- APPLIANCa CIRCUIT AT IWO VA E.L <br />9000 <br />1 LAUNORY CIRCUIT <br />1500 <br />I RANGE AT NA PLATE RATTNG OR COONTOP/OVEN <br />12000 <br />I wATER r TER <br />4800 <br />I DISHVASHER <br />1200 <br />1 CI01'ETES DRYER <br />6000 <br />1 DISPOSAL <br />SOO <br />1 WCROWAVE <br />1800 <br />1 REFRIGERATOR <br />1200 <br />SUB'ITIT- OF <br />—w <br />ITP3P 10 EVA OF GENERAL LOAD AT 100% <br />10000 <br />R2NAINDER OF GENERAL LOAD AT 40N 28203 VA x .4 <br />11282 <br />TOTAL NET GF2iERAL TOAD <br />21282 <br />S.S TON HEAT PUMP (W/ ENw F.'AD+ROENCY HE— STRIP) <br />21 240 VAS <br />SS TON COo.— 9YSTEx 40 ANP z 240 VA- <br />• F800 <br />NET GE-- W- <br />2— <br />NET TOTAL HVAC <br />9800 <br />TOTAL LOAD <br />s0882 <br />CALCULATED LOAD FOR SERVICE <br />908S2 VA/240 V- 128 AYP <br />150 AMP SERVICE <br />•woRST cAse scaxARlo - x1GxEST xvAc LOAD <br />USED FOR CAIGUWT20NS.• <br />NEUTRAL CALCULATION: <br />LIGHTING, APLLIANCE, LAUNDRY LOADS: 14,283 VA <br />3000 VA a 100%, REMAINDER a 35% <br />NET LOAD: 6,94e VA <br />RANGE: 12APOO a 10% 8,400 VA <br />DRYER: 5000 a 10% 33�VA <br />TOTAL 18,849 VA <br />NEUTRAL AMPACITY: 18,489 / 240 = 18 A <br />2 AL MINIMUM NEUTRAL CONDUCTOR. <br />PROVIDE 3 "1 CU, I % CU GND 2" CONDUIT OR PROVIDE <br />3 2/0 AL, 1 F4 AL GND 1N 2" CONDUIT. <br />(CONDUIT TO TERMINATE ABOVE SOFFIT a OVERHANG.) <br />150 AMP ELECTRICAL R15ER <br />NOT TO SCALE. COMBINATION SERVICE 110 AMP <br />DISCONNECT SWITCH AND 120/240 VOL <br />GENERAL NOTES: M ELECTRIC METER IN I PHASE <br />A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL NEMA 3R ENCLOSURE MLO <br />COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 5TH PANEL <br />EDITION (2014). LOCAL CODES, AND ALL LOCAL POWER <br />COMPANY REQUIREMENTS. 150A/2P <br />B. ALL CONDUCTORS SHALL BE TYPE THHN/THWN UNLESS MCB <br />NOTED OTHERWISE. <br />POWER COMPA <br />TRANSFORMER <br />GRADE <br />PROVIDE 150 AMP, 120/240 VOLT, 1 PHASE SECONDARY - <br />ELECTRICAL SERVICE. PROVIDE 3 •1 COPPER CCU) IN <br />1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 <br />2/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC <br />CONDUIT UNLESS SERVICE 15 PROVIDED BY THE <br />ELECTRIC COMPANY, COORDINATE WITH THE ELECTRIC <br />COMPANY PRIOR TO BID. <br />TELEPHONE SERVICE CABLE TELEVISION' <br />ENTRANCE SERVICE ENTRANCE <br />EQUIPMENT EOUIPMENT <br />INTERSYSTEM BCWDING <br />TERMINAL AT LOW <br />VOLTAGE CONNECTIONS <br />1 •4 CU SERVICE GROUND CONNECTED TO <br />CONCRETE ENCASED FOOTER STEEL PER <br />ELECTRICAL PROVISIONS OF THE FBCR 5TH <br />EDITION (2014) <br />5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD <br />A N C N I T E C T <br />Design <br />Grou 1r2G. <br />1441 N. RONAAREAGANLONGWOPH: 407FAX: 40www.abdeAA#: <br />x <br />ti <br />V <br />y <br />4O <br />K <br />y <br />4 <br />F <br />0 <br />i <br />BXMDIV. as LOT <br />SILVERADO <br />LOT 7 <br />BLK 1 <br />PROJWT# <br />04128.000-07001 <br />itl ODRU <br />4EHB <br />"2605—HAYDEN" <br />GARAGE EIT►MG: <br />LEFT <br />PAGE: <br />FIRST <br />FLOOR <br />ELECTRICAL <br />PLAN <br />50 MPH EXP. B <br />ARCHITECT <br />STATE OF FLONDA <br />[ 1-7 <br />A AL93723 <br />CRA <br />AR NO <br />DR MA10/21/16 <br />EICALE: 1 /4"=1'— 0" <br />SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.