My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36039 Carriage Pine Ct
Zephyrhills
>
Building Department
>
Building Plans
>
36039 Carriage Pine Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:08:25 PM
Creation date
2/19/2025 12:05:52 PM
Metadata
Fields
Template:
Building Plans
Street #
36039
Location
Carriage Pine Ct
Contractor
DR Horton
Building Plans - Permit #
17929
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />L ALL MECHANI AL BQMrl' Kr AWALL= rRoVMXO YRTN row= CLEARANCE, FOR S6lVICM rm <br />MIS; <br />2 ALL DUCT ShSTl M INSTALLED N NON-CRORIOMM!D AMAA AH" W CONMTI NOW OF A VALUR <br />OF NO LESS, TNMN R-i RATNS: ALL OR" SMALL OE SEALED OMTW ftAS6 FM 4 MIASTM AND <br />NATALLBD AS PER FOCR Wn4 EDR10N C20M4) FECii WAL OLM CODE SECTION M:l: <br />A ALL RAX 01111GT6 SMALL OR APPROVED UL w LLAMA I AN DUCT AS PER NPPA I" 2-3J <br />4L NNMfSM AIR MAIM ALL tM OE LOCAT® CLOAB! TMAN 10 FT L FROMI ANY CWWM:Y OR VENT <br />OUTLET, OR 6ANTANY AWIIt VER OUTLET <br />S. ALL E)6WIST AND MUM Alt NLRT DUCT6, AWLL iDE CCNSIN== OF SP OOTM OALV. METAL <br />OR OTMEMt MNAININALS AA FM FI = WrM OPMON f1014) MICMW MCAL CODE SECTION &M <br />6. ENCLOSED SU OPM FLANCRIO SMALL OR CON67RIIGTED N ACCORDANCE TO FOCR S7M EDITION <br />(20M) MNQL4NMCAL CODE 6M <br />1L OA1FSt041% OONTAIMM EIATINIRMW SNOAO M 6PAS AND 614LANR OATMM FDf11MEs SMALL OR <br />MECHANICALLY VVINTED N ACCOICAWSI Wn4 FOCR ST14 RDTTION (301W 11EGYWCAL CODE <br />SECTION 40SL <br />a ALL D6iWSTED OATH ROOMS, SMALL HAVE IMDE"W DOOM FOR MA:04r AN TO OE <br />RRT1M!!D, TO RQWIL Alt IND04 STED. <br />% ALL FOE RATED CRLNS6 AND WALLS MALL WAVE AN APPROVED FM OR 191EAlTQQ <br />CA PMG LOCATED AT CIELM OR WALL FORTRATION AND DE SLMVM MMTW ACCiSS, DOOR6 TO <br />POINT DAMPER ALL DAMM M SMALL OE INSTALLED TO M4L 1E00M E OATI" AND FOM STN <br />EDITION (204M) MMiCHAINCAL CODE SECTION Mn <br />10. WISLLM AND OrPM fRb SMALL = PROVOW OT14 OALAWCM DAI VEM <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETUFa4 <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />1 <br />AIR HANDLER <br />I�— <br />L <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />-_ <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 5TH EDITION (2014) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.1.1 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. F'L. <br />BRASS PLUG <br />r- 1 <br />I I <br />INSIDE <br />CAULK 1 <br />FIN. FLOOR <br />OR WALL <br />PITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />SERIES NICKEL BRASS TOP <br />P.V.0 OPTI/SPEC <br />IV. SEE <br />aITE PLAN <br />OFLOOR SLAB CLEAN -OUT (TYPNT- <br />LEGEND <br />® <br />SI -MY AN PrP AW <br />m <br />MrAW AIR CELL <br />® <br />AIDE -WALL OR I WAY ONWIR <br />— <br />!OLD LINE- OIMTLY TIOSK <br />— <br />OROM LMt- PWRNN TINISK <br />1 <br />OALAmcm DAMPER on COD <br />O <br />CRILM WOWS? FAN <br />CELM ID04A T FAN 4 L1SMR <br />O/A <br />OUTSIDE AMR <br />m <br />THOW40 TAT <br />02 <br />FOAS-71 M AN GRILL <br />SECURE STRAP TO GONG CONDENSER <br />W/ (2)-3/I6'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />'8XI 1/4' BHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD ® 12' FROM STRUCTURE <br />COUNTERSUNK <br />C.O. PLUG <br />6 <br />SEE SPEC. <br />_ -�C <br />\`\\ <br />71 <br />.. <br />- - - - - - - - - - <br />'k <br />. <br />FIN. GRADE -' q- <br />-R <br />OR PAVING T—_-T <br />FITTING OR <br />I <br />EXTENSION TO SOIL <br />OR WASTE AS <br />I <br />REQUIRED <br />I <br />Y <br />- <br />SITES <br />SITT N <br />LA <br />PLAN <br />vEXT. GROUND <br />CLEAN -OUT (TYPN) <br />T <br />FIRST FLOOR MECHANICAL PLAN <br />PROGRESSIVE AIR 06/15/14 <br />A R C N I T E C T A <br />6 <br />Grou i .n <br />41 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX 407-7744078 <br />www.abdesigngmp.com <br />AA 4: 0003325 <br />F <br />w <br />y <br />0 <br />h <br />C <br />0 <br />SRJEFDIN. a LOT: <br />SILVERADO <br />LOT 2 <br />BLK 2 <br />0441128.0000-02002 <br />moan <br />4EGB <br />"GALEN" <br />OIARAOIME aw1PTOl: <br />RIGHT <br />"'NRST <br />FLOOR <br />MECHANICAL <br />PLAN <br />%150 MPH EXP. B <br />ARCMifTECT: <br />STATE OF FLOPMA <br />DATE: 10/24/16 <br />SICALL': 1 /4"=1'- O" <br />81iEIDT <br />10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.