My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36039 Carriage Pine Ct
Zephyrhills
>
Building Department
>
Building Plans
>
36039 Carriage Pine Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:08:25 PM
Creation date
2/19/2025 12:05:52 PM
Metadata
Fields
Template:
Building Plans
Street #
36039
Location
Carriage Pine Ct
Contractor
DR Horton
Building Plans - Permit #
17929
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIBERGLASS SHINGLES <br />OVER 030 FELT PAPER <br />INSTALLED PER FBCR <br />R9052.1 ON J' O.S.B. <br />SHEATHING OR J' CDX <br />PLYWOOD SECURED PER <br />FASTENER SCHEDULE <br />PRE-ENG TRUSS <br />P.T. IX2 W/ MTL. DRIP EDGE <br />2x4 OR 2x6 SUB -BAND <br />PER ELEVATIONS <br />VENTED ALUM. SOFFIT <br />DOUBLE TOP PLATE <br />WINDOW HEADER SIZE <br />VARIES PER WINDOW <br />OPENING SEE HEADER <br />SPAN CHART FOR <br />DETAILS <br />O.S.B. SHEATHING OR J' <br />CDX PLYWOOD. <br />ATTACHED PER FASTENER <br />SCHEDULE ON SHEET D5. <br />1/8' THICK, 3 COAT <br />PORTLAND CEMENT <br />PLASTER OVER <br />EXPANDED GALV'D <br />METAL LATH ON <br />FORTIF15ER JUM50TEX <br />GRADE 'D' PAPER OVER <br />TYVEK BUILDING WRAP <br />(REFER TO STUCCO <br />SPECS FOR COMPLETE <br />INFORMATION) <br />NOTE: SHEATHING MUST <br />NOT BREAK I'-4' MIN. <br />FROM 2ND FLR LINE <br />2x4 CONT. 6 TOP AND <br />BT. OF FLR TRUSS (TOP <br />2x4 SUPPORTS BT <br />PLATE OF 2ND FLR, BT. <br />2x4 IS FOR WALL <br />SHEATHING NAILER) <br />WEEP SCREED <br />(SEE DETAIL 2/D3) <br />EMBED. STRAP VERIFY <br />W/ TRUSS PLAN <br />%' THICK, 3 COAT <br />PORTLAND CEMENT <br />PLASTER APPLIED <br />DIRECTLY TO MASONRY <br />2-STORY <br />FIRST FLOOR <br />BLOCK SECOND <br />1 FLOOR FRAME <br />SCALE: 3/4'=1'-0' <br />SEE N CODE FORMS <br />INSULATION NSULAULA TION R-VALUES <br />1' GYPSUM BOARD OR <br />HIGH STRENGTH CLG. <br />BOARD <br />TWIST STRAP VERIFY W/ <br />TRUSS PLAN <br />WINDOW ATTACHMENT AS <br />PER MANUFACTURES <br />SPECIFICATIONS <br />UNDOW SILL <br />?x STUDS 6 16' O.C. MAX W/ <br />NSUL., SEE ENERGY CODE <br />:OR`9S FOR INSULATION <br />2-VALUES <br />i' T 4 G 5U5FLOOR GLUED <br />4ND SCREWED AS PER <br />:45TENER SCHEDULE <br />IRE-ENG FLOOR TRUSS <br />'INSTALL PER MFG, SPECS.) <br />�' GYPSUM BOARD OR <br />41GH STRENGTH CLG. <br />BOARD <br />::ONC. FILLED LINTEL BLK W/ <br />'I) 05 REBAR CONTINUOUS <br />BEE ENERGY CODE FORMS <br />:OR INSULATION R-VALUES <br />(RECAST LINTEL <br />JJINDOW ATTACHMENT AS <br />-ER MANUFACTURES <br />5PECIF ICAT IONS <br />'RECAST SILL <br />:I) 05 REBAR VERTICALLY <br />W/ CONC. POURED CELL <br />Ix2 P.T. FURRING STRIPS <br />to 16' O.C. <br />8' CMU <br />V2' GYP. WL. BD. <br />WOOD BASE <br />FIBERGLASS SHINGLES <br />OVER 030 FELT PAPER <br />INSTALLED PER FBCR <br />R9052.1 ON J' O.S.S. <br />SHEATHING OR I' CDX <br />PLYWOOD SECURED PER <br />FASTENER SCHEDULE <br />P.T. IX2 W/ MTL. DRIP EDGE <br />2x4 OR 2x6 SUB -BAND PER <br />ELEVATIONS <br />VENTED ALUM. SOFFIT <br />STIFFBACK AT ALL <br />UPRIGHTS OVER 4'-10' <br />HIGH (SEE SEALED ENG. <br />FOR SIZE 4 CONDITION) <br />SECURE 2x4 PLATE TO WALL W/ <br />i'x6' THRU-BOLTS a+ 32' O.C. <br />MAX THEN SECURE GABLE TO <br />2x4 PLATE W/ 12d's 8' O.C. MAX <br />OR <br />SECURE GABLE TO DBL TOP <br />PLATE W/ SIMPSON HTC4 9 24' <br />O.C. MAX <br />WINDOW HEADER SIZE VARIES <br />PER WINDOW OPENING SEE <br />HEADER SPAN CHART FOR <br />DETAILS <br />D.S.B. SHEATHING OR J' CDX <br />PLYWOOD. ATTACHED PER <br />FASTENER SCHEDULE ON SHEET <br />D5 <br />1/6' THICK, 3 COAT PORTLAND <br />CEMENT PLASTER OVER <br />EXPANDED GALV'D METAL LATH <br />ON FORTIF15ER JUM50TEX <br />GRADE 'D' PAPER OVER TYVEK <br />BUILDING WRAP (REFER TO <br />STUCCO SPECS FOR COMPLETE <br />INFORMATION) <br />NOTE: SHEATHING MUST NOT <br />BREAK I'-4' MIN. FROM 2ND FLR <br />LINE <br />2x4 CONT. g TOP AND BT. OF <br />FLR TRUSS (TOP 2x4 SUPPORTS <br />BT PLATE OF 2ND FLR, BT, 2x4 <br />IS FOR WALL SHEATHING <br />NAILER) <br />WEEP SCREED <br />(SEE DETAIL 2/D3) <br />EMBED. STRAP VERIFY <br />W/ TRUSS PLAN <br />THICK, 3 COAT <br />PORTLAND CEMENT <br />PLASTER APPLIED <br />DIRECTLY TO MASONRY <br />2-STORY GABLE <br />FIRST FLOOR <br />BLOCK SECOND <br />-A FLOOR FRAME <br />SCALE: 3!4'=1'-0' <br />2x4 BLOCKING BETWEEN <br />TRUSSES WHERE 'X' BRACING <br />15 PRESENT <br />PRE-ENG GABLE TRUSS <br />CONT. 2x4 RAT RUN SECURED <br />W/ (2) 12d's o EACH TRUSS <br />ENERGY CODE FORMS <br />INSULATION R-VALUES <br />1' GYPSUM BOARD OR }' <br />HIGH STRENGTH CLG. <br />BOARD <br />DOUBLE TOP PLATE <br />WINDOW ATTACHMENT AS <br />PER MANUFACTURES <br />SPECIFICATIONS <br />WINDOW SILL <br />2x STUDS m 16' O.G. MAX W/ <br />INSUL., SEE ENERGY CODE <br />FORMS FOR INSULATION <br />R-VALUES <br />4' T 4 G 5UBFLOOR GLUED <br />AND SCREWED AS PER <br />FASTENER SCHEDULE <br />PRE-ENG FLOOR TRUSS <br />(INSTALL PER MFG. SPECS.) <br />1' GYPSUM BOARD OR <br />HIGH STRENGTH CLG. <br />BOARD <br />CONC. FILLED LINTEL BLK W/ <br />(1) 45 REBAR CONTINUOUS <br />PRECAST LINTEL <br />WINDOW ATTACHMENT AS <br />PER MANUFACTURER <br />SPECIFICATIONS <br />PRECAST SILL <br />(U 05 REBAR VERTICALLY <br />W/ CONIC. POURED CELL <br />Ix2 P.T. FURRING STRIPS <br />9 16' O.C. <br />8' CMU <br />1/2' GYP. WL. BD. <br />WOOD SASE <br />FIBERGLASS SHINGLES <br />OVER 130 FELT PAPER <br />INSTALLED PER FBCR <br />R5052.1 ON a' 0.8$. <br />SHEATHING OR 1' CDX <br />PLYWOOD SECURED PER <br />FASTENER SCHEDULE <br />PRE-ENG TRUSS <br />P.T. IX2 W/ MTL. DRIP EDGE <br />2x4 OR 2x6 SUB -BAND <br />PER ELEVATIONS <br />VENTED ALUM. SOFFIT <br />1,0000 UPLIFT <br />CONNECTOR <br />2x8 SYP e2 <br />DBL TOP <br />PLATE <br />WALL <br />SHEATHING <br />2x8 SYP 02 — <br />WOOD STUDS <br />AT 12' O.G. MAX <br />2x8 P.T. SYP 02 <br />SOLE PLATE <br />S REBAR 9 16 <br />O.C. MAX, IN <br />CONCRETE <br />POURED CELL, <br />VERIFY PER <br />PLAN, <br />SEE ENERGY <br />CODEFORMS� <br />FOR <br />INSULATION <br />R-VALUES z w <br />r Q 2 Q <br />_i [l! <br />WALL1-1 <br />SECTION -I <br />WOOD <br />FRAME TO 3 <br />1B LOCK WALL <br />SEE ENERGY CODE FORMS <br />FOR INSULATION R-VALUES <br />I' GYPSUM BOARD OR }' <br />HIGH STRENGTH CLG. <br />BOARD <br />SIMPSON <br />SP2 9 EA. <br />2X8 STUD <br />DRY WALL <br />}' DIA ANCHOR BOLT <br />AT 16' O.C. MAX WITH 1' <br />EMBEDMENT AND 2' <br />DIA. WASHER <br />SIMPSON SPI <br />,w EA. 2X8 <br />STUD <br />(1) COURSE TIE -BEAM <br />POURED SOLID WITH <br />CONCRETE. (1) 05 <br />REBAR HORIZONTALLY <br />PRECAST LINTEL <br />WINDOW ATTACHMENT AS <br />PER MANUFACTURES <br />SPECIFICATIONS <br />-PRECAST SILL <br />Ix2 P.T. FURRING STRIPS <br />0 16' O.G. <br />8' CMU <br />I/2' GYP. WL. BD. <br />(1) 04 CONTINUOUS REBAR <br />WOOD BASE <br />04 REBAR 40' LONG <br />W/6' HOOK 0 24' O.C., <br />MIN. 24' IN SLAB <br />2'-0" (MIN. <br />IN SLAB) <br />i ° 9 <br />° <br />4' CONC., REINF. W/ 6'x6' <br />a_ <br />WI.4XWI.40 WW`1 ON 6-MIL POLY <br />ETHYLENE VAPOR BARRIER ON <br />WELL -COMPACTED CLEAN FILL <br />TERMITE TREATMENT SHALL BE <br />BORA-CARE <br />(3) «5 REBAR ON CHAIRS <br />2x STUDS a IV O.C. MAX W/ <br />11c 0.5.8. SHEATHING OR }' CDX <br />2x STUDS o 16' O.G. MAX W/ <br />NOTE: <br />INSUL., SEE ENERGY CODE <br />PLYWOOD. ATTACHED PER <br />INSUL., SEE ENERGY CODE <br />PER FBCR 9052.1 - FOR ROOF SLOPES 2:12 TO <br />FORMS FOR INSULATION <br />FASTENER SCHEDULE ON SHEET <br />FORMS FOR INSULATION <br />LESS THAN 4:12, A (2) LAYER UNDERLAYMENT <br />R-vALUES <br />p5 <br />R-VALUES <br />SYSTEM IS REQUIRED. FOR ROOF SLOPES OF <br />4' T 4 G SUBFLOOR GLUED <br />1/8' THICK, 3 COAT PORTLAND k <br />4' T 4 G SUBFLOOR GLUED <br />4:12 OR GREATER, (1) LAYER UNDERLAYMENT IS <br />AND SCREWED AS PER <br />CEMENT PLASTER OVER <br />AND SCREWED AS PER <br />PERMITTED BUT MUST BE PER ABTM D226 TYPE <br />FASTENER SCHEDULE <br />EXPANDED GALV'D METAL LATH <br />FASTENER SCHEDULE <br />II, ASTM D 4865 TYPE IV, OR ASTM D 6151 <br />ON FORTIF15ER JUMIBOTEX <br />GRADE 'D' PAPER OVER TYVEK <br />3/4' T 4 G SUBFLOOR GLUED <br />BUILDING WRAP (REFER TO <br />AND SCREWED AS PER <br />STUCCO SPECS FOR COMPLETE <br />FASTENER SCHEDULE ON <br />INFORMATION) <br />SHEET D2 <br />2x4 CONT. e TOP AND BT. OF <br />FLR TRUSS (TOP 2x4 <br />PRE-ENG FLOOR TRUSS <br />SUPPORTS BT PLATE OF 2ND <br />PRE-ENG FLOOR TRUSS <br />FASTEN 2X4 RIBBON (P.T. 0 <br />FLR, BT. 2x4 IS FOR WALL <br />CMU) W/ (3) 12d NAILS 9 EACH <br />SIMPSON HETA-16 EMBED. <br />SHEATHING NAILER) <br />J' GYPSUM BOARD OR %' <br />TRUSS <br />STRAP g 32' O.C_ MAX VERIFY <br />WEEP SCREED <br />(SEE DETAIL 2/D3) <br />HIGH STRENGTH CLG. <br />BOARD <br />PRE-ENG FLOOR TRUSS <br />W/ TRUSS PLAN <br />EMBED. STRAP VERIFY <br />(INSTALL PER MFG. SPECS.) <br />' GYPSUM BOARD OR <br />W/ TRUSS PLAN <br />CONIC. FILLED LINTEL BLK W/ <br />HIGH STRENGTH CLG. BOARD <br />%' THICK, 3 COAT PORTLAND <br />(1) 45 REBAR CONTINUOUS <br />CONC. FILLED LINTEL BLK W/ <br />CEMENT PLASTER APPLIED <br />(I) "5 REBAR CONTINUOUS <br />DIRECTLY TO MASONRY <br />RIBBON <br />FLOOR CONNECTION AT PARALLEL/ <br />2 PERPENDICULAR PRE-ENG FLOOR TRUSS <br />@,FASTENING DETAIL <br />SCALE: 3/4' = I'-O' <br />SCALE: 3/4' = I'-0' <br />A R C N IT E C T! <br />Design <br />Gr w �. <br />41 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 J <br />w <br />y <br />w <br />0 <br />w <br />0 <br />a <br />a <br />a <br />3 <br />M <br />1`.04128.000- 02002 <br />][ODEL: <br />4EGB <br />"GALEN" <br />GARAGE SIRNG: <br />RIGHT <br />PAGE: <br />MONOLITHIC <br />2-STORY <br />WALL <br />SECTIONS & NOTES <br />%J50 MPH EXP. B <br />ARCHITECT: <br />STATE OF FLORIDA <br />s <br />P TM D10/24/16 <br />SCALE: 1 /4"=1'— 0" <br />8*xwzT <br />D4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.