Laserfiche WebLink
BACKER ROD <br />BACKER ROD <br />WRB LAYER "I, <br />STUCCO WRAP <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHfNG OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE: <br />I. BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIOES,YW CAULKING a JOINT <br />ALL AROUND <br />PER FBC R703.6.01 <br />Exterior lathing and plastering <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-11A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-11 A. <br />HOODED VENT <br />iC, <br />I <br />I' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER "2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />6A DRYER VENT <br />(FRAME) <br />WOOD SHEATHING <br />WRB LAYER M, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD — <br />CONSTUCTION <br />—METAL LATH <br />8' CMU <br />VINYL CASING BEAD <br />6' RAISED BAND <br />- 36' TO %' MID -WALL <br />WEEP SCREED <br />b' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />.1 MASONRY BEFORE APPLYING <br />I Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />7C HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER *I, STUCCO WRAP) <br />WRB LAYER *2 (FORTIFIBER - - - - - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />ELEC. METEf <br />VERIFY LO <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP a SIDES <br />SELF <br />FLAS14ING <br />UNIT <br />PREMANUR DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT o <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />l <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />�1VENT PENETRATION <br />1-1 SCALE: N.T.S. <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT WBACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING - - - - - <br />NOTE: <br />METAL LATH: LATH TO BE PER FBC Q <br />R103.6.1 / ASTM G-&41-12, MIN. 2.5 L55. 8 <br />PER 5Q. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />CONSTRUCT ION <br />WOOD SHEATHING <br />WRB LAYER "I, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />g' THICK, 3 COAT CEMENT <br />PLASTER <br />T/8' TO %' MID -WALL <br />WEEP SCREED <br />f �—eo' SELF-ADHESIVE <br />I FLASHING <br />WOOD FRAMED <br />WALL <br />ONTAL <br />�A HORIZWEEP SCREED <br />(FRAME TO FRAME <br />�. METER FIELD <br />VERIFY LOCATION <br />I <br />ELEC <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (I) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />15OCYANOTE-POLYBLEND FOAM <br />7R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />70 SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />CTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER "I, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THA' <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAC <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHEATHING <br />LAYER M, <br />STUCCO WRAP <br />WRB LAYER '2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />WOOD 1/8' TEXTURED <br />CONSTRUCTION I,��FINISH • WOOD <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER T' O.C. MAX <br />a' CMU - <br />is'�- <br />\ - WEEP SCREED <br />f' R Z <br />� E� <br />• 6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />—TEXTURED <br />FINISH • MASONRY <br />�B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK <br />a <br />WRB LAYER •1, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF-AOI-IERfW. <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />STET= #1 <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP #3 <br />STEP #2 <br />WRB LAYER -1, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />WRB LAYER •2, FORTIFIBER <br />BUILDING PAPER <br />STET= <br />#4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />,t <br />METAL LATH <br />STEP #5 STEW #ro <br />ELECTRICAL RECEPTACLE <br />A R C H IT E C T S <br />0nc.n <br />1441 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX 407-774-4078 <br />www.abdesigngroup.com <br />AA k: 0003325 <br />w <br />i <br />y <br />a <br />coi <br />2 <br />0 <br />U <br />0 <br />614 <br />2 <br />B <br />d <br />H <br />d � <br />EIUDDIV. Sg LOT. <br />SILVERADO <br />LOT 8 <br />BLK 1 <br />PR OJECT T04128.00 -08001 <br />HODELs <br />4EBB <br />"1828—CALL" <br />GARAGE aTIMG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EV. B <br />ARCHITECT- <br />STATE OF FLORIDA <br />DA'ltt 10/21/16 <br />aCALM: 1/4"=1'-0" <br />aflEar <br />A2 <br />