My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36060 Carriage Pine Ct
Zephyrhills
>
Building Department
>
Building Plans
>
36060 Carriage Pine Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:28:15 PM
Creation date
2/19/2025 11:58:28 AM
Metadata
Fields
Template:
Building Plans
Street #
36060
Location
Carriage Pine Ct
Contractor
DR Horton Inc
Building Plans - Permit #
17926
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBCR 5TH EDITION (2014) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 161 CLASS I AIR DUCT A5 PER NFPA 90A 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBCR 5TH EDITION (2014) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBCR 5TH EDITION <br />(2014) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND 51MILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBCR 5TH EDITION (2014) MECHANICAL CODE <br />SECTION 403. <br />6. ALL EXHAUSTED BATH ROOM5, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBCR 5TH <br />EDITION (2014) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF NO DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE= SUPPLY TRUNK <br />--- <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />4 <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />(`) <br />THERMOSTAT <br />ED <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />�_ <br />��� <br />EXTERIOR WALL <br />PLENUM <br />y-� <br />AIR RETURN <br />1 <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />I� <br />y <br />REFRIGERANT LINES <br />--� <br />� <br />II <br />�— <br />I <br />y I <br />AIR HANDLER <br />Ij <br />EXTERIOR WALL <br />SECURE STRAP TO CONC. <br />CONDENSER <br />PVC CONDENSATE DRAIN LINE <br />W/ (2)-3/16'X2' TAPCONS <br />UNIT <br />SIMPSON WB ROLL STRAP <br />EVAP.TRAY <br />yPVC <br />SLEEVE TO LINES BELOW SLABOR <br />EQUAL <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURNCONDENSING <br />L3/4' <br />UNIT5ECURE <br />DRAIN LINE AND TERMINATE <br />STRAP TO UNIT W/ (2)TRAP <br />4' CONCRETE SLAB •8XI I/d' SHT. MTL. SCREWS <br />IN AN APROVED DRAIN, AS PER <br />FE,CR 5TH EDITION <br />� <br />MECHANICAL BLDG.. CODE <br />ME <br />ME <br />CONDENSER UNIT <br />SECTION 3012.1.1 <br />HVAC <br />DRAINS <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD s 12' FROM STRUCTURE <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />BRASS PLUG <br />INSIDE I — <br />CAULK J <br />y II, i <br />II; , <br />�FIN. FLOOR <br />OR WALL <br />I <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 5240-K JOSAM 56000 <br />SERIES NICKEL BRA55 TOP <br />P.V.0 OPTI/SPEC <br />IV. SEE_ <br />aiTE AN <br />OFLOOR SLAB CLEAN —OUT (TYPNT) <br />COUNTERSUNK <br />C.O. PLUG <br />I _6. <br />--�� SEE SPEC. <br />--------i i---------- <br />L._'._.JAI'-8'X8 <br />CONC. <br />FIN. GRADE <br />OR PAVING <br />-- <br />FITTING OR <br />I <br />EXTENSION TO SOIL <br />I <br />OR WASTE AS <br />r-- <br />- REQUIRED <br />I <br />II <br />I <br />it <br />— <br />INV. SEE <br />15I------�"--ATE PLAN <br />NEXT. GROUND <br />CLEAN —OUT (TYPN <br />MECHANICAL PLAN <br />PROGRESSIVE AIR SYSTEMS 05/20/14 <br />A R C H I T E C T S <br />6 <br />NsiOn <br />Grou .2 <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774,6078 <br />FAX 407-7744078 <br />www.abdesigngroup.com <br />AA 8: 0003325 <br />w <br />U <br />2 <br />F <br />4 <br />a <br />c, <br />y <br />0 <br />F <br />a <br />Q <br />BUHDIV. Ae LOT <br />SILVERADO <br />LOT 9 <br />BLK 1 <br />PROJECT# <br />04128.000-09001 <br />MODEL: <br />4EAB <br />"1672-ARIA" <br />GARAGE BVrDCG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />ARCHITECT. - <br />STATE OF FLORIDA <br />(I r q <br />DA 10/21/16 <br />SCAM: 1/4 1'- 0" <br />slacuT <br />6 <br />