My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36096 Carriage Pine Ct
Zephyrhills
>
Building Department
>
Building Plans
>
36096 Carriage Pine Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:36:48 AM
Creation date
2/19/2025 12:05:02 PM
Metadata
Fields
Template:
Building Plans
Street #
36096
Location
Carriage Pine Ct
Contractor
DR Horton
Building Plans - Permit #
18048
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />WRB LAYER'(, <br />STUCCO WRAP <br />6A DRYER VENT <br />WOOD - <br />CONSTUCTION <br />e' CMU <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE: <br />I. BOTTOM 2. SIDES 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 15 TO BE <br />TOOLED 50 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, V CAULKING ® JOINT <br />ALL AROUND <br />PER FBC R703.6.01 <br />Exterior lathing and plastering <br />Exterior use of portland cement plaster <br />shall comply With the application <br />requirements of ASTM C 926-11 A. <br />Installation of exterior lathing and framing <br />shall comply With ASTM C 1063-1IA. <br />_- <br />HOODED VENT <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER'), FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />( FRAME) <br />WOOD SHEATHING <br />WRB LAYER'(, <br />STUCCO WRAP <br />WRB LAYER `2, FOFMFIBER <br />BUILDING PAPER <br />METAL LATH <br />- VINYL CASING BEAD <br />- W RAISED BAND <br />Ye' TO %' MID -WALL <br />WEEP SCREED <br />0' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />�C HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER #I, STUCCO WRAP) <br />WRB LAYER #2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO'- " T <br />WOOD SHEATHING11 <br />SELF-ADHESIVE FLASHING <br />NOTE: <br />METAL LATH: LATH TO BE PER FBC <br />R'103.6.1 / ASTM C-84-1-12, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />ro' SELF ADHESIVE <br />OVER TOP a SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT v <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH — <br />WALL <br />6' SELF ADHESIVE <br />FLASHING (INSTAL <br />PER MANUF. SPEC <br />BUILDING PAPER <br />UNDER 'QUICK FLE <br />WENT PENETRATION <br />SCALE: N.TS. <br />ELEC. METEF <br />VERIFY LO <br />H7GN V RGL.GVG <br />5TUCC0 SCRATCH COAT <br />4 1 COAT OF PAINT W/BAGK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 'I, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />g' THICK, 3 COAT CEMENT <br />PLASTER <br />3/a" TO 5/a' MID -WALL <br />WEEP SCREED <br />'k�6" SELF-ADHESIVE <br />FLASHING <br />-7—WOOD FRAMED <br />WALL <br />�A HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME <br />i ELEG. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />IC <br />^r ')R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC, WIRE PENETRATES <br />:;0 SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER "I, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT — <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHEATHING <br />WRB LAYER'(, <br />STUCCO WRAP <br />WRB LAYER 1, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />WOOD <br />1/8' TEXTURED <br />CONSTRUCTION <br />�.��FINISH • WOOD <br />" FASTEN TO WOOD STRUCTURAL <br />MEMBER s l' O.G. MAX <br />8 CMI� <br />Yp' i0 %' MID -WALL <br />WEEP 6GREED <br />—tea <br />• 6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />TEXTURED <br />FINISH a MASONRY <br />�B HORIZONTAL WEEP SCREED <br />(FRAME TO TO BLOCK) <br />WRB LAYER -4, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />STEfi= *11 <br />APPLY 600 MIN <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />AF'ROVED <br />WOUSEWRAP <br />STET= #3 <br />b <br />STE i= #2 <br />WRB LAYER "I, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />WRB LAYER 12, FORTIFIBER <br />BUILDING PAPER <br />STET= #4 <br />ELA5TOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />6TEF *5 51Efi= *ro <br />OELECTRICAL RECEPTACLE <br />A R C N I T E C T S <br />WDesign <br />Grou tnc. <br />L . rtVRNLV RCMIfWY 6LY U. <br />LONGWOOD, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />y <br />w <br />a <br />W <br />0 <br />a <br />V <br />0 <br />ti <br />m <br />d <br />F <br />sysD:v 4k LOT: <br />SILVERADO <br />LOT 12 <br />BLK 1 <br />PROJECT <br />04128.07-12001 <br />MODEL: <br />4EBB <br />"1828— CALI" <br />GARAGE 8111ING: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />ARCHITECT <br />STATE OF FLORDA <br />0y1mbA <br />DAT 11/02/16 <br />SCALE: 1 /4"=1' — 0" <br />sximmT <br />dd A2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.