1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE, RESIDENTIAL (FBCR), STH <br />EDITION (2014) AND IN CONJUNCTION WITH ASCE 7-10. <br />2. THE MINIMUM SUPERIMPOSED DESIGN LOADS ARE AS FOLLOWS; <br />A FLOOR LIVE LOADS R301.5 (PSF) <br />1. SLEEPING ROOMS 30 <br />11. ATTICS WI STORAGE 20 <br />" <br />III. ATTICS W/OLR STORAGE 10 <br />IV. POOLROOMS 75 <br />V. BALCONIES AND DECKS 40 <br />VI. STAIRS 40 <br />VII. ALL OTHER ROOMS 40 <br />B. FLOOR DEAD LOADS R301 A 10 (PSF) <br />C. ROOF LIVE LOADS R301.6 " <br />I. "MINIMUM ROOF LIVE LOADS SHALL COMPLY WITH TABLE R301.6 OF THE FBCR 5TH EDITION (2014) <br />D. ROOF DEAD LOAD (PSF) <br />1. FIBERGLASS SHINGLES 17 (TCDL 7 & BCDL 10) <br />IL CONCRETE TILES 25 (TCDL 15 & BCDL 10) <br />E. WIND LOAD CRITERIA <br />1. BASIC WIND SPEED VULT=150 MPH, VASD=116 MPH <br />IL EXPOSURE CATEGORY B <br />III. WIND DIRECTIONALITY FACTOR (KD) 0.85 <br />IV. INTERNAL PRESSURE COEFFICIENT (GCPI) <br />ENCLOSED BUILDINGS t0.18 <br />V. RISK CATEGORY It <br />9. EXCAVATIONS TO BE A MINIMUM OF 3'- 0" BEYOND NEW FOOTING LINE. <br />10. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE REQUIREMENTS. <br />11. THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WITHIN A FLOOD ZONE, UNO. CONTRACTOR IS TO VERIFY THE ELEVATION <br />OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPUTES WITH ALL LOCAL CODES HAVING <br />JURISDICTION, INCLUDING ALL APPLICABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES. <br />12. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP DRAWINGS. <br />CONCRETE <br />1. ALL CONCRETE WORK SHALL COMPLY WITH THE LATEST EDITION OF THE STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE <br />IN BUILDINGS, ACT 301, AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACT 318-08. <br />2. ALL CONCRETE FOR THE FOOTINGS, SLABS ON GROUND, AND MISCELLANEOUS ITEMS SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH OF 2500 PSI AFTER 28 DAYS, UNLESS NOTED OTHERWISE ON THE DRAWINGS AND PROVISIONS OF R402.2. <br />3. ALL AGGREGATES USED IN CONCRETE SHALL CONFORM TO ASTM C33-03. MAXIMUM AGGREGATE SIZE SHALL BE'/.'. <br />4. PROVIDE 6% AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER. <br />5. BRACE FOUNDATION WALLS, RETAINING WALLS, DURING BACKFILLING AND TAMPING OPERATIONS. LEAVE BRACING IN POSITION <br />UNTIL PERMANENT RESTRAINTS ARE INSTALLED. <br />6. ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED W. <br />7. PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON <br />DRAWINGS. SEAMS LAPPED 61NCHES AND SEALED WITH ADHESIVE TAPE. <br />I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER <br />D. TRUSS PLATE INSTITUTE: <br />I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI-1-07) <br />E. APA-THE ENGINEERED WOOD ASSOCIATION: <br />1, ENGINEERED WOOD CONSTRUCTION GUIDE <br />F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS <br />2. ALL STRUCTURAL LUMBER SHALL BE SOUTHERN YELLOW PINE #2 (MIN.) MACHINE GRADED LUMBER, UNO. <br />Fb =1,500 PSI Fv =175 PSI E=1,600,000 PSI <br />STRUCTURAL LUMBER SHALL CONSIST OF, BUT NOT LIMITED TO; RAFTERS, VERTICAL STRONGBACKS, LEDGERS, BEAMS, <br />HEADERS, AND POSTS, <br />3. LUMBER FOR INTERIOR BEARING WALLS OR EXTERIOR WALLS SHALL BE SOUTHERN YELLOW PINE #2 (SYP #2) OR BETTER (UNLESS NOTED <br />OTHERWISE). <br />4. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. <br />5. MINIMUM NAILING PER FBCR, 5TH EDITION (2014), SEE TYPICAL NAILING SCHEDULE ON PLANS. <br />6. ALL BOLTS SHALL HAVE MINIMUM 2" SQUARE STANDARD CUT WASHERS UNDER HEADS AND/OR NUTS WHERE IN CONTACT WITH WOOD. <br />7. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL CONFORM TO SECTION R602.2.3 & R8021.8. OF THE FBCR 5TH EDITION (2014). <br />8. FOR ASPHALT SHINGLE ROOFS, SHEATHING SHALL BE STRUCTURAL GRADE 7/16" OSB EXPOSURE-1 OR 1/2" COX PLYWOOD SHEATHING. <br />PROVIDE PANEL -CLIPS AT MID -SPAN FOR SPANS GREATER THAN 16" ON CENTER AND AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING. <br />9. FOR CEMENTITIOUS TILE ROOFS, SHEATHING SHALL BE 5/8' CDX PLYWOOD. 5/8' CDX SHEATHING SHALL BE INSTALLED WITH THE <br />STRENGTH AXIS RUNNING PERPENDICULAR TO THE TRUSSES AND SHALL SPAN A MINIMUM OF TWO TRUSS BAYS. PROVIDE PANEL -CLIPS <br />AT MID -SPAN FOR SPANS GREATER THAN 16' ON CENTER AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING. <br />F. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR BUILDING <br />OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WIND BORNE DEBRIS BY THE INSTALLATION <br />8. CONTRACTOR/OWNER TO PROVIDE SOIL REPORT TO ARCHITECT PRIOR TO ANY CONSTRUCTION. <br />10. FLOOR SHEATHING SHALL BE APA RATED %"SUBFLOOR T & G INTERIOR PLYWOOD, GLUED AND SCREWED. ADHESIVES CONFORMING <br />OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE DESIGNED AND <br />WITH PERFORMANCE SPECIFICATION AFG-01 SHALL ONLY BE USED. <br />INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, 5TH <br />9. FLOOR ELEVATIONS AT REQUIRED EGRESS DOOR SHALL MEET PROVISION OF FBCR R311.3.1. <br />EDITION (2014). <br />11. WALL SHEATHING SHALL BE STRUCTURAL GRADE 7116' OSB EXPOSURE-1 OR 1/2" CDX PLYWOOD SHEATHING. <br />MASONRY <br />3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK <br />1. MASONRY CONSTRUCTION SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF SECTION 606 OR WITH <br />12. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT . SQ. <br />PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. <br />PROVISIONS OF TMS 4021 ACT 5301 ASCE 5. <br />13. PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND COLUMNS WITH 2x STRUCTURAL LUMBER SYP #2. <br />4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE <br />2. CONCRETE MASONRY UNITS SHALL BE GRADE "N" TYPE 11 OR EQUAL AND, IN ACCORDANCE WITH ASTM C90-06b, STANDARD <br />ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR <br />SPECIFICATIONS FOR HOLLOW LOAD -BEARING CONCRETE MASONRY UNITS, MINIMUM COMPRESSIVE STRENGTH OF F'm =1500 <br />E <br />14. TRUSS MANUFACTURER SHALL PROVIDE COMPLETE CALCULATIONS SHOWING INTERNAL LAYOUT, MEMBER FORCES AND STRESS CONTROL <br />WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OMISSIONS THE CONTRACT DOCUMENTS, OF <br />PSI. <br />POINTS AND SUBMIT THE BUILDING DEPARTMENT FOR APPROVAL AND TO THE STRUCTURAL ENGINEER FOR REVIEW. ALL CALCULATIONS <br />WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK. <br />SHALL BE SIGNED AND SEALED BY A PROFESSIONAL CIVIL OR STRUCTURAL ENGINEER REGISTERED IN THE STATE OF THE PROPOSED <br />3. OPEN-END BLOCK MAY BE SUBSTITUTED FOR STANDARD TWO CELLED BLOCK. <br />CONSTRUCTION. <br />5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, <br />OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. <br />6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR SHALL <br />SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL <br />PERMANENT MEMBERS ARE COMPLETELY INSTALLED. <br />7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. <br />1 8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. <br />9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. <br />GARAGES AND CARPORTS <br />1. GARAGE DOOR <br />A ENGINEERED FOR 150 MPH MIN, WIND LOAD. <br />B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER <br />C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER <br />2. PER FBCR 5TH EDITION (2014) R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES <br />SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD <br />DOORS NOT LESS THAN 1 3/8INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1-3/8 INCHES THICK, <br />OR 20-MINUTE FIRE -RATED DOORS AND MUST BE EQUIPPED W/ A SELF -CLOSING DEVICE PER R307.5.1. <br />3. PER FBCR 5TH EDITION (2014) R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING <br />THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL 1' MIN. RIGID <br />NON-METALLIC CLASS OR CLASS i DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. <br />4. PER FBCR 5TH EDITION (2014) R302.6 & TABLE R302.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC <br />AREA BY NOT LESS THAN %-INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS <br />SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 518 -INCH TYPE X GYPSUM BOARD OR <br />EQUIVALENT. WHERE THE SEPARATION IS A FLOOR-CEIUNG ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL <br />ALSO BE PROTECTED BY NOT LESS THAN Y INCH GYPSUM BOARD OR EQUIVALENT. <br />SITE WORK <br />1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS. <br />2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, SITE <br />IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL DRAWINGS SHALL OVERRIDE <br />CONFLICTS WITH SITE WORK NOTED HEREIRSEE LANDSCAPE DRAWINGS FOR FINAL FINISH GRADES, PLANTING AND IRRIGATION. <br />3. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL REINFORCING FOR ALL FOUNDATIONS. DESIGN WAS BASED ON <br />AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS BEEN DELETED UNLESS NOTED <br />OTHERWISE. <br />4. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE ARCHITECT. <br />5. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN %THE HORIZONTAL DISTANCE FROM THE <br />NEAREST EDGE OF THE FOOTING. <br />I 6. ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAR OF GRANULAR FILL. PLACE IN 8' LAYERS AND <br />COMPACT TO 95%MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557, THE BUILDING SITE SHALL BE KEPT DRY SO <br />THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS. <br />7. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. <br />4. MORTAR SHALL BE TYPE M OR SIN ACCORDANCE WITH ASTM C270-07, STANDARD SPECIFICATIONS FOR MORTAR FOR MASONRY. 15. TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF LOCATIONS WITH GUSSETS, <br />CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR INTERSECTIONS OF HIGHER OR LOWER ROOFS IN <br />5. MORTAR JOINTS FOR ALL BED AND HEAD JOINTS ARE TO BE 3181NCH THICK. THE BED JOINT OF THE STARTING COURSE MAY ACCORDANCE WITH ANSI A58.1-1982. <br />VARY BUT IT SHALL NOT BE LESS THAN %INCH AND NOT MORE THAN % INCH, REFER TO FBCR 5TH EDITION (2014), SECTION R607.2.1 i6. PREFABRICATED TRUSS TOP AND BOTTOM CHORD LOADS SHALL BE PER THE RECOMMENDED MINIMUM DESIGN LOADS IN APPENDIX B OF <br />FOR MORTAR JOINT THICKNESS TOLERANCES. THE ANSI/TPI 1-2007 NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION. LIVE LOAD DEFLECTIONS <br />6. GROUT SHALL BE IN ACCORDANCE WITH ASTM C476, STANDARD SPECIFICATIONS FOR GROUT FOR MASONRY, OR -I PSI PEA SHALL BE LIMITED TO U360. DEAD PLUS LIVE LOAD DEFLECTIONS SHALL BE LIMITED TO U240. <br />ROCK CONCRETE PER SPECIFICATIONS AND PROVISIONS OF SECTION R609.1.2.OF THE FBCR 5TH EDITION (2014). <br />7. FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL REINFORCING. <br />17. THE CONNECTIONS FOR ALL TIMBER EXPOSED TO EXTERIOR ELEMENTS OR TO PRESSURE TREATED LUMBER SHALL BE GALVANIZED OR <br />PAINTED WITH A CORROSION RESISTANT POLYMER PAINT. <br />8. MASONRY WALLS SHALL BE LAID IN A RUNNING BOND PATTERN OR, IF A STACK BOND PATTERN IS TO BE USED 9 GA. LADDER TYPE 18. ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "SIMPSON' STRONG -TIE BY SIMPSON CO., OR EQUAL. UNLESS <br />HORIZONTAL JOINT REINFORCEMENT IS TO BE INSTALLED IN THE BED JOINTS SPACED AT 16" ON CENTER (MAX). NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS WITH THE SIZE AND NUMBER OF BOLTSINAILS AS RECOMMENDED BY THE <br />MANUFACTURER IN THE LATEST CATALOG, <br />REINFORCING STEEL <br />1. ALL CONCRETE AND MASONRY STEEL REINFORCEMENTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR DETAILING <br />REINFORCED CONCRETE STRUCTURES, ACT 315; THE STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE IN BUILDINGS, <br />ACT 301; AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACT 318-08. <br />2. REINFORCING BARS SHALL BE OF INTERMEDIATE GRADE CONFORMING TO ASTM A615, GRADE 40 (UNO). <br />3. WELDED WIRE FABRIC SHALL BE W X 6"- W1.4 X W1.4 AND SUPPLIED IN FLAT SHEETS OR ROLLS CONFORMING TO ASTM A185. LAP <br />SIDES AND ENDS A MINIMUM OF 12". LOCATE WWF 2" FROM THE TOP OF THE SLAB, UNLESS OTHERWISE NOTED ON THE PLANS. <br />THIS REINFORCEMENT SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 34".R506.2.5(2) <br />4. ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, THICKENED SLAB, BEAM OR LINTEL <br />SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS <br />THROUGHOUT THE HEIGHT OF THE WALL, WITH LAP SPLICES OF AT LEAST 25". <br />5. RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL INTO INTERSECTING WALLS AND <br />HOOK AT ENDS. STAGGER SPLICES AT LEAST 25' WHEREVER POSSIBLE. <br />6. CLEARANCE OF MAIN REINFORCING BARS FROM ADJACENT CONCRETE SURFACES SHALL BE: <br />A CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH _3' <br />B. CONCRETE EXPOSED TO EARTH OR WEATHER: <br />I. #5, W31 OR D31 AND SMALLER 2' <br />C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: <br />I. #11 AND SMALLER <br />D. BEAMS, COLUMNS: <br />I. PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS 1%' <br />7. DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS WITHOUT THE <br />APPROVAL OF THE ARCHITECT. <br />TIMBER <br />1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED HEREIN: <br />A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) <br />B. NATIONAL FOREST PRODUCTS ASSOCIATION: <br />I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION <br />19. DRAFTSTOPPING SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R302.12. OF THE FBCR 5TH EDITION (2014). <br />PLUMBING <br />1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. <br />2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX'A' (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. <br />3. CONDENSATION LINES SHALL BE MINIMUM''/.' PVC (SCHEDULE 40), INSULATED WITH 1/:" AMAFLEX. <br />4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH. <br />5. ALL CLEANOUiS SHALL BE FLUSH WITH GRADE. <br />6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. <br />7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2 OF THE FBCR 5TH EDITION (2014). <br />8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903 OF THE FBCR 5TH EDITION (2014). <br />9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. <br />10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.2 OF THE FBCR 5TH <br />EDITION (2014). <br />EXTERIOR WALL COVERINGS <br />1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR THE WALLS FOR <br />COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301.2(2) AS MODIFIED BY TABLE R301.2(3), MANUFACTURED SOFFITS <br />SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE <br />EXTERIOR FINISHES <br />1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, 7%' THICK, OVER FRAMED WALLS APPLIED OVER <br />PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS THAN TWO COATS, 1/2" THICK, <br />WHERE APPLIED OVER MASONRY OR CONCRETE. <br />2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM-C926 & ASTM-C1063-06. <br />2-STORY GYPSUM BOARD <br />UNDER STAIR PROTECTION: <br />1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE <br />ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. FBCR R302.7. CONTROL DATE: 07/15/15 <br />L441 N. KUNALU KtA6AN tlLVU. <br />LONG WOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX 407-7744078 <br />www.a bdesigngroup.com <br />AA #: 0003325 <br />w <br />y <br />0 <br />F <br />y <br />0 <br />F <br />i <br />w <br />V <br />SLTHDIV. at M-14 <br />SILVERADO <br />LOT 25 <br />BLK 1 <br />PlLoj=Tpp <br />04128.00-25001 <br />moDEL: <br />4EBB <br />"1828- CALI" <br />GARAGE SIWMG: <br />RIGHT <br />PAGE: <br />GENERAL <br />NOTES <br />50 MPH EXP. B <br />ARCHITECT <br />STATE OF FLOPoDA <br />S <br />POP <br />m 11/07/16 <br />SCALE: 1/4"=V-0" <br />SHEET <br />GN <br />