My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36146 Carriage Pine Ct
Zephyrhills
>
Building Department
>
Building Plans
>
36146 Carriage Pine Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:15:54 AM
Creation date
2/19/2025 12:05:16 PM
Metadata
Fields
Template:
Building Plans
Street #
36146
Location
Carriage Pine Ct
Contractor
DR Horton
Building Plans - Permit #
18050
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br />SYMBOL <br />DEFINITION <br />NOTES <br />-e <br />115V OUTLET <br />W A SNdLE POLE <br />IIOV OUTLET <br />IR)V OUTLET <br />TTC 'SWTCH `TV WRED <br />�dFI <br />IIOV OUTLET <br />Ea1T®IW'�aO FAIL <br />NIERIPfER (T.MTPER <br />IffdeTANT TTPEI <br />E0 <br />220V OUTLET <br />l YYAE GCft1ECTICN <br />-CF GFI <br />ExT. MATERPn2DF <br />OUTLET JNIERBPIER <br />OROIND FAULT <br />SWITCH <br />SUNTCH <br />3-WAT OPER <br />%4 <br />SWITCH <br />4-WAY OFER <br />WALL MCWTED <br />L KiFff <br />CEILING I — <br />F1�F <br />\OJ`VP <br />LK%rt <br />pRE <br />aftD CAN <br />W4LL SCCNCE <br />FRE•WP® <br />YENi. RAN <br />CN1 PER _ FT. <br />KM. FAN <br />I CFM PER SC2 FT. <br />W1KAR <br />V F0(DIFi <br />lSFEC'S <br />TKO eT <br />1-BILLS LLRAP <br />r—� <br />FL�JBCENi <br />4190HID <br />2' FLGCRESCENf <br />�q-_p_� 4'FWDIEdfNT <br />4' TRACK LKift <br />d0Il PANEL <br />miam METER <br />• SD. enGl� DETeerae ,y(y�� <br />9D. WALL YgIMED 69Ti. BAIX-IP <br />EfiCA� DETECTOR YEtlA�Il� <br />BATT_ BACK-W uY <br />DET — N]ER-COMECIEp <br />SHALL eE A DISTANCE <br />PBlIDAM LKi1R <br />�LTIRAL GAe <br />TELCF�+DtE 1Acx <br />UP <br />WATER NEATER <br />DIBCQO.ECf <br />TD G! ELEvdIED <br />, <br />FLOW LKi <br />cpr. eEamrY <br />KETTAD <br />HE Pa. Fud+-BUTTON FDR wn 5 <br />.�� ueB PDRr <br />COTES; <br />LOCATION OF TV JACKS 4 PHONE OUTLETS I <br />FANS TO BE VERIFIED • HOMEOU.NER <br />PRE -CONSTRUCTION MEETING. <br />ALL RECEPTACLES IN ALL HABITABLE <br />ROOMS TO BE ARC FAULT PROTECTED PER <br />ELECTRICAL PROVISIONS OF FBCR 5TH <br />EDITION (2014). <br />20 AMP DEDICATED LAUNDRY CIRCUIT. <br />GFI • ISLAND (NOT ON KITCHEN CIRCUIT) <br />DISHWASHER DISCONNECT TO BE LOCKOUT <br />IN PANEL <br />BATHROOM EXHAUST FAN TO HAVE MIN. <br />CAPACITY OF 50 CFM INTERMITTENT PER <br />ELECTRICAL PROVISIONS OF SECTION <br />MI5013 FBCR 5TH EDITION C20141. <br />LAUNDRY ROOM RECEPTACLE $HALL BE <br />GROUND FAULT CIRCUIT -INTERRUPTER <br />PROTECTION FOR PERSONNEL ON FEEDERS <br />WIRING METHOD $HALL BE NON METALLIC <br />CABLE PER ELECTRICAL PROVISIONS OF <br />FBCR 5TH ED (2014). <br />ALL RECEPTACLE$ TO BE TAMPER - <br />RESISTANT TYPE <br />ALL WORK TO COMPLY WITH ELECTRICAL <br />PROVISIONS OF THE FBCR 5TH ED l2014). <br />ALL LAMP$ $HALL BE $ELECTED BY <br />BUILDER AND l % OF LIGHTING MUST BE <br />ENERGY EFFICIENT TYPE PER FB.G. ENERGY <br />CONSERVATION (RESIDENTIAL ENERGY <br />EFFICIENCY) 2014. 5th EDITION R404.1 <br />PATIO <br />SWITCH IN <br />CABINET GFI <br />HOOD WIRE W W <br />FUTURE MICRO. ! LET FOR RR%E& <br />?III - —- PRE -WIRED <br />CLG FAN <br />F 1 OUTLET\ <br />TJ FOR DW <br />I REM K TI CHEN <br />PPPAN ��wGFI \�y� TO 2NDIFLL,', <br />ST SIIJI�C 4�l <br />STORI <br />PRE -WIRED <br />CLG FAN <br />FLEX <br />I <br />\\ LL <br />I E <br />3 <br />19® I C <br />I <br />j FOYER <br />I, <br />I sT <br />B. FOR <br />slC'jHIMES <br />PORCH <br />)-a FOR <br />\ <br />GARAGE <br />\ <br />DOOR <br />\ <br />\ <br />\ <br />KEYLE55 <br />FIXTURE <br />GFI <br />GARAGE <br />DOOR <br />PREWIIRRE <br />a <br />WH <br />O <br />BOLLARD J <br />AS REO. <br />PER BLDG. <br />CODE <br />IRRIGATION <br />OUTLET a <br />48' AFF. <br />METER <br />FIELD <br />VERIFY <br />LOC. <br />FIRST FLOOR ELECTRICAL PLAN <br />LOAD CALCULATIONS ONE FAMILY <br />DWELLING WITH HEAT PUMP <br />REC CODE 92) <br />HOUSE PLAN: MODEL "'GALEN" <br />LOAD INFORMATION <br />VA <br />2498 39 FT GENERAL LI.— X S VA PER Sp FT <br />7296 <br />2 20 A r APPLIANCE CACUTT AT Ie00 VA EA <br />SOOo <br />LAUNDRY CDiNR <br />1600 <br />RANGE AT NAYS PLATE RwTAo OR COOKTVP/OVBa <br />12000 <br />1 WATER HEATER <br />-o0 <br />1 DLIHNASHER <br />1200 <br />1 clnTHa DRTRR <br />500o <br />] DAPos.M. <br />50o <br />t REFRIGERATOR <br />120o <br />SUBTOTAL of GENERAL WAD <br />3]696 <br />FAST LO "A OF GENERAL WAD AT 100E <br />10000 <br />REMAIITDER OF GII10UL WAD AT 401i 90oSe VA z <br />O]S <br />TOTAL NET GENERAL WAD <br />210]e <br />9.5 TON HEAT (N/ — EMEROETSY HEAT STRIP) <br />21 AMP x 240 VM <br />as To. COOLDNG SY9T'RM 40 AMP : 240 vw <br />- 9soo <br />NET GENOtAt WAD <br />210]9 <br />NET TOTAL HVAC <br />9e00 <br />TOTAL WAD <br />906]9 <br />CALCULATED LOAD FOR SERVICE <br />SOe]B vA/240 V� ]29 AYP <br />150 AN, SERVICE <br />•1POR5T CASE SCENAMO - HIGHEST HVAC WAD <br />USED FOR CAIGULATIONS.• <br />NEUTRAL CALCULATION: <br />LIGHTING, APPLIANCE, LAUNDRY LOADS: 14,283 VA <br />3000 VA a 100%, REMAINDER a 35% <br />NET LOAD: 6,949 VA <br />RANGE: 12.000 6 -70% 8,400 VA <br />DRYER: 5,000 s 10% 3500 VA <br />TOTAL I8,B4S VA <br />NEUTRAL AAPACITY: 18,48E / 240 - l8 A <br />e2 AL MINIMUM NEUTRAL CONDUCTOR <br />PROVIDE 3 e1 CU, I Vo CU GND 2" CONDUIT OR PROVIDE <br />3 "2/0 AL, 1 •4 AL GND IN 2°' CONDUIT. <br />(CONDUIT TO TERMINATE ABOVE SOFFIT A OVERHANG.) <br />150 AMP ELECTRICAL RISER <br />NOT TO SCALE. COMBINATION SERVICE 150 AMP <br />DISCONNECT SWITCH AND 120/240 VOLT <br />GENERAL NOTES: M ELECTRIC METER IN I MLOSE <br />A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL NEMA 3R ENCLOSURE <br />COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 5TH PANEL <br />EDITION (2014). LOCAL CODES, AND ALL LOCAL POWER <br />COMPANY REQUIREMENTS. 150A/21- <br />e. ALL CONDUCTORS SHALL BE TYPE THI-IN/THWN UNLESS MCB <br />NOTED OTHERWISE. <br />POWER COMPANY <br />TRANSFORMER <br />el 7r-14 <br />PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY - <br />ELECTRICAL SERVICE. PROVIDE 3 w1 COPPER (CU) IN <br />1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 <br />"2/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC <br />CONDUIT UNLESS SERVICE IS PROVIDED BY THE <br />ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC <br />COMPANY PRIOR TO BID. <br />TELEPHONE SERVICE CABLE TELEVISION <br />ENTRANCE SERVICE ENTRANCE <br />EQUIPMENT EQUIPMENT <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW <br />VOLTAGE CONNECTIONS <br />- 1 e4 CU SERVICE GROUND CONNECTED TO <br />CONCRETE ENCASED FOOTER STEEL PER <br />ELECTRICAL PROVISIONS OF THE FBCR 5TH <br />EDITION (2014). <br />5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD <br />A R C N I T E C T S <br />6 <br />Gm i In <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />ww mbdeRigngroup.Gom <br />AA N: 0003325 <br />rV <br />h <br />41 <br />O <br />0 <br />F <br />O <br />F <br />ti <br />x <br />0 <br />e <br />auim ae LOT <br />SILVERADO <br />LOT #16 <br />BLK #1 <br />PROJECT* <br />04128,000-16001 <br />MODEMe <br />4EGB <br />"GALEN" <br />GARAGE 01WMG: <br />RIGHT <br />PAGE: <br />FIRST <br />FLOOR <br />ELECTRICAL <br />PLAN <br />50 MPH EXP. B <br />ARCHITECT <br />STATE Or- FLORIDA <br />f n'I <br />u J <br />I <br />DARITIT : 11/07/16 <br />$GALE 1/4"=1'-0" <br />82iEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.